scholarly journals Improved Sensitive High Performance Liquid Chromatography Assay for Glucosamine in Human and Rat Biological Samples with Fluorescence Detection

2010 ◽  
Vol 13 (2) ◽  
pp. 128 ◽  
Author(s):  
Fakhreddin Jamali ◽  
Alyaa Ibrahim

Purpose. An improved HPLC method with fluorescence detection was developed and validated for determination of glucosamine in human and rat biological samples. Method. Aliquot of 0.1 mL plasma was spiked with mannosamine HCl as the internal standard (IS); proteins were precipitated with acetonitrile; the clear layer was derivatized with 9-fluorenylmethyl chloroformate (8 mM/acetonitrile) in presence of borate 0.2 M buffer at 30o C for 30 min. The excess derivatizing agent was removed with 1-aminoadamantane HCl (300 mM in acetonitrile-water 1:1). Chromatographic separation was achieved on a C18 (100mm X 4.6 mm, id 3μm) reversed phase column using 0.1% acetic acid/acetoniltrile gradient mobile phase at 1 mL/min flow rate. Glucosamine was determined in the plasma of a human and rats and also in rat urine. Results. The analytes were detected at excitation and emission wavelengths of 263 and 315 nm, respectively. The assay was linear over the range of 0.05-20 µg/mL with a typical correlation coefficient of 0.999 and intra-day and inter-day coefficient of variation of

2011 ◽  
Vol 8 (1) ◽  
pp. 340-346 ◽  
Author(s):  
Rajesh M. Kashid ◽  
Santosh G. Singh ◽  
Shrawan Singh

A reversed phase HPLC method that allows the separation and simultaneous determination of the preservatives methyl paraben (M.P.) and propyl paraben (P.P.) is described. The separations were effected by using an initial mobile phase of water: acetonitrile (50:50) on Inertsil C18 to elute P.P. and M.P. The detector wavelength was set at 205 nm. Under these conditions, separation of the two components was achieved in less than 10 min. Analytical characteristics of the separation such as precision, specificity, linear range and reproducibility were evaluated. The developed method was applied for the determination of preservative M.P. and P.P. at concentration of 0.01 mg/mL and 0.1 mg/mL respectively. The method was successfully used for determining both compounds in sucralfate suspension.


INDIAN DRUGS ◽  
2016 ◽  
Vol 53 (11) ◽  
pp. 46-50
Author(s):  
Z. G Khan ◽  
◽  
S. S. Patil ◽  
P. K. Deshmukh ◽  
P. O. Patil

Novel, isocratic reversed phase high performance liquid chromatography method was developed and validated for the determination of enzalutamide (EZA) in bulk drug and pharmaceutical formulation. Efficient separation was achieved on PrincetonSPHER C18 100A, 5μ (250×4.6 mm) under the isocratic mode of elution using acetonitrile: water (80:20) % V/V as a mobile phase pumped in to the column at flow rate 1.0 mL/min. The effluent was monitored at 237.0 nm using UV detector. EZA was eluted in the given mobile phase at retention time (tR) of 3.2 minutes. The standard calibration curve was linear over the concentration range 10 - 60 μg/mL with correlation coefficient 0.997. The method was validated for accuracy, precision, sensitivity, robustness, ruggedness and all the resulting data treated statistically. The system suitability parameters like retention time, theoretical plates, tailing factor, capacity factor were found within the limit.


1984 ◽  
Vol 30 (7) ◽  
pp. 1228-1230 ◽  
Author(s):  
A K Dhar ◽  
H Kutt

Abstract This method for determination of haloperidol in plasma is based on "high-performance" isocratic liquid chromatography with the use of a C8 bonded reversed-phase column at room temperature. Haloperidol and the internal standard (chloro-substituted analog) are extracted from alkalinized plasma into isoamyl alcohol/heptane (1.5/98.5 by vol) and back-extracted into dilute H2SO4. The aqueous phase is directly injected onto the column. The mobile phase is a 30/45/25 (by vol) mixture of phosphate buffer (16.5 mmol/L, pH 7.0), acetonitrile, and methanol. Unlike other liquid-chromatographic procedures for haloperidol, commonly used psychotropic drugs do not interfere. Analysis can be completed within an hour. The procedure is extremely sensitive (1.0 microgram/L) and is well reproducible (CV 5.6% for a 2.5 micrograms/L concentration in plasma).


1998 ◽  
Vol 44 (7) ◽  
pp. 1481-1488 ◽  
Author(s):  
Maria Shipkova ◽  
Paul Dieter Niedmann ◽  
Victor William Armstrong ◽  
Ekkehard Schütz ◽  
Eberhard Wieland ◽  
...  

Abstract We describe a reversed-phase HPLC method for determination of total mycophenolic acid (MPA), its free concentration (MPAf), and the glucuronide metabolite (MPAG), based on simple sample preparation and gradient elution chromatography. The compounds were quantified in parallel by absorbance at 254 nm and 215 nm in the internal standard mode. Linearity was verified up to 50 mg/L for MPA and up to 500 mg/L for MPAG (r >0.999). Detection limits at 215 and 254 nm were, respectively, 0.01 and 0.03 mg/L for MPA, and 0.03 and 0.1 mg/L for MPAG. The recovery of MPA was 95–106%;recovery of MPAG was 96–106%. The imprecision (CV) for MPA (0.2–25 mg/L) was <8.4% (254 nm) and <4.4% (215 nm) within day (n = 12) and <9.2% (254 nm) and <6.2% (215 nm) between days (n = 12). The imprecision for MPAG (10–250 mg/L) was <4.9% (254 nm) and <3.4% (215 nm) within day, and <6.1% (254 nm) and <5.9% (215 nm) between days. For quantification of MPAf, 100 μL of ultrafiltrate was applied directly to the column. The detection limit was 0.005 mg/L at 215 nm and 0.015 mg/L at 254 nm. In the range between 18–210 μg/L, the within-day CVs were <11.8% (n = 12) and the between-day CVs were <15.8% (n = 12).


2017 ◽  
Vol 1 (2) ◽  
pp. 1-8
Author(s):  
Milena Cristina Ribeiro Souza Magalhães ◽  
Alisson Samuel Portes Caldeira ◽  
Hanna De Sousa Rocha Almeida ◽  
Sílvia Ligório Fialho ◽  
Armando Da Silva Cunha Junior

A reversed-phase high-performance liquid chromatographic (HPLC) method was developed and validated for the determination of encapsulation efficiency of zidovudine in nanoparticules. The method was carried out in isocratic mode using 0.040M sodium acetate: methanol: acetonitrile: glacial acetic acid (880:100:20:2) as mobile phase, a C8 column at 25ºC and UV detection at 240 nm. The method was linear (r2 ˃ 0.99) over the range of 25.0-150.0 μg/mL, precise (RSD ˂ 5%), accurate (recovery = 100.5%), robust and selective. The validated HPLC-UV method can be successfully applied to determine the rate of zidovudine in nanoparticules.


1988 ◽  
Vol 34 (4) ◽  
pp. 724-729 ◽  
Author(s):  
M Hariharan ◽  
T VanNoord ◽  
J F Greden

Abstract We describe a rapid, sensitive method for the routine simultaneous determination of nicotine and cotinine in 1 mL of plasma. Extraction in 10-mL screw-capped Teflon tubes with methylene chloride after deproteinization with trichloroacetic acid eliminated emulsion formation. The extract, after evaporation and reconstitution in 30 microL of mobile phase, is injected into a reversed-phase C-18 ion-pair column of an isocratic high-performance liquid-chromatographic unit. Absorbance is monitored at 256 nm. The mobile phase is a citrate-phosphate (30 mmol each per liter) buffer mixture containing 50 mL of acetonitrile and 1 mmol of sodium heptanesulfonate per liter. 2-Phenylimidazole is the internal standard. The detection limit is 1 microgram/L for nicotine and 3 micrograms/L for cotinine. The standard curve is linear from 0 to 700 micrograms/L for both compounds. The average CV for nicotine in the concentration range 0-100 micrograms/L is 6.5%, and that for cotinine in the concentration range 50-700 micrograms/L is 4%.


2010 ◽  
Vol 93 (4) ◽  
pp. 1059-1068 ◽  
Author(s):  
Predrag Lj Džodić ◽  
Ljiljana J ivanovi ◽  
Ana D Proti ◽  
Mira L Zeevi ◽  
Biljana M Joci

Abstract An accurate and precise RP-HPLC method was developed and validated for the determination of carbamazepine and its impurities iminostilbene and iminodibenzyl in a tablet formulation with fluphenazine as an internal standard. Buffermethanol (50 + 50, v/v) was used as the mobile phase. During validation, specificity, linearity, precision, accuracy, LOD, LOQ, and robustness of the method were tested. The method was proven to be specific against placebo interference. Linearity was evaluated over the concentration range of 100500, 0.050.25, and 0.10.5 g/mL, and the r values were 0.9994, 0.9997, and 0.9979 for carbamazepine, iminostilbene, and iminodibenzyl, respectively. Intraday precision of the method was good, and RSD was below 2 for all analytes. The accuracy of the method ranged from 100.69 to 102.10, 99.76 to 102.66, and 99.26 to 100.08 for carbamazepine, iminostilbene, and iminodibenzyl, respectively. LOD was 0.0125, 0.025, and 0.05 g/mL and LOQ was 0.05, 0.05, and 0.1 g/mL for carbamazepine, iminostilbene, and iminodibenzyl, respectively. Robustness of the method was proven by using a chemometric approach. The method was successfully applied to the analysis of commercially available carbamazepine tablets and showed good repeatability, with RSD below 2.


2012 ◽  
Vol 95 (4) ◽  
pp. 1064-1068 ◽  
Author(s):  
Mohammed H Mehanna ◽  
Abdel M Motawaa ◽  
Magda W Samaha

Abstract A reliable and sensitive HPLC method was developed for the quantitation of tadalafil transdermal permeation through human skin. An RP column with UV detection at 290 nm was used for chromatographic separation at ambient temperature. The mobile phase was acetonitrile–water containing 20 mM pH 7 phosphate buffer (35/65, v/v) with a flow rate of 1.0 mL/min. The LOQ achieved was 1 ng/mL, and the calibration curve showed good linearity over the concentration range of 5–2000 ng/mL for tadalafil, with a determination coefficient (R2) of 0.998. The RSD values of intraday and interday analyses were all within 7%. Parameters of validation proved the precision of the method; this validated method was applied for the determination of tadalafil in transdermal permeation and drug deposition in human skin studies.


1997 ◽  
Vol 43 (8) ◽  
pp. 1386-1391 ◽  
Author(s):  
Ursula Turpeinen ◽  
Helene Markkanen ◽  
Matti Välimäki ◽  
Ulf-Håkan Stenman

Abstract We here report a reversed-phase HPLC method for the determination of free cortisol in human urine, using methylprednisolone as the internal standard. Before chromatography, samples were extracted with a C18 solid-phase extraction column and the steroids were separated on a LiChrospher 100 C18 column with a mobile phase of methanol/acetonitrile/water (43/3/54 by vol). Linearity, precision, and accuracy of the method were established. The detection limit was 10 pmol of cortisol, and total CVs were <8%. With various solid-phase extraction columns the recovery of cortisol was 36–97%; recovery of the internal standard was 43–85%. Study of interference by 6 other steroids and metabolites and 24 drugs showed that carbamazepine and digoxin partly overlapped with cortisol, but this interference could be reduced by modification of the mobile phase. The HPLC method was compared with an RIA and an automated immunoassay method. The results obtained by HPLC averaged 40% of the RIA values.


1988 ◽  
Vol 34 (9) ◽  
pp. 1897-1899 ◽  
Author(s):  
M H Cheng ◽  
W Y Huang ◽  
A I Lipsey

Abstract This high-performance liquid-chromatographic (HPLC) method for simultaneous determination of prednisone and its metabolite, prednisolone, in plasma is a modification of the method of Frey et al. (Clin Chem 1979;25:1944-7). Heparinized plasma (1.0 mL) with 0.1 mL of internal standard solution (11-deoxy-17-hydroxycorticosterone, 2 mg/L) is extracted with 7.0 mL of dichloromethane, then washed sequentially with 0.1 mol/L HCl, 0.1 mol/L NaOH, and deionized water, 2.0 mL each. The extract is evaporated and the residue reconstituted with 75 microL of mobile phase, methanol/H2O (40/60 by vol). Thirty microliters of this is injected onto a reversed-phase C6 column, which is eluted at 1.4 mL/min. Analytical recoveries of prednisone and prednisolone were 94-98% and 102-106%, respectively. Day-to-day precision (CV) was 3.8% for prednisone, 6.1% for prednisolone. We encountered no interference from the 21 other steroids and 25 drugs tested. This method is simple, accurate, and precise.