scholarly journals Thermodynamic Features and Design of Solar-Air Source Composite Heating System

2020 ◽  
Vol 38 (4) ◽  
pp. 967-975
Author(s):  
Na Ni

Facing the huge energy consumption of buildings, it is highly practical to study every aspect of energy-saving technologies for heating and cooling devices. Solar thermal technology and air/water source heat pump are two popular energy-saving technologies, which could be combined into a composite heating system with good energy-saving effect and efficiency. This paper constructs a solar-air source composite heating system, analyzes its thermodynamic features, and builds up the corresponding thermodynamic model. In addition, the authors modeled the daytime and nighttime heat balances, as well as the monthly cumulative heat supply for the constructed system. Finally, a dual-tank composite heating system was designed with independent heat supply/storage. The proposed models and system were proved valid and scientific through experiments.

2014 ◽  
Vol 953-954 ◽  
pp. 1578-1583
Author(s):  
Tian Yu Xiong ◽  
Xiu Zhang Fu ◽  
Jian Dong

Rural dwellings have a big difference in the appearance and envelope. Living form is changing a lot from detached house to the apartment in multi-story apartments. These changes affect building’s energy consumption consisting of heating and cooling. This paper focuses on the impact of the energy consumption affected by different surface volume ratios, simulation analysis showed a general argument of the difference. And for the same house type, this paper also compares the energy-saving effect of different envelop performances, Specific contents are the heat transfer coefficient and shading ways. Simulation results identified that SVR has influence on different types of houses, the energy consumption of row houses can be saved more than 30% compared with detached houses. Envelope performance also affects energy consumption and the national standard is recommended for the energy saving and the comfort.


2012 ◽  
Vol 516-517 ◽  
pp. 1139-1143
Author(s):  
Ke Chun Sun ◽  
Wei Jun Zhang

Chongqing weather conditions as the representative, energy simulation software DesT-c Chongqing office building energy simulation analysis, simulated natural building under different ventilation conditions at room temperature, the energy consumption of building cooling load and air-conditioning system changes, with an emphasis on energy-saving effect of the night ventilation; The study showed that in Chongqing reasonable use of ventilation reduce building natural room temperature to a certain extent; Sensitive indicators of building air conditioning energy consumption than the heating energy consumption of ventilation was significantly; Night ventilation when the number of ventilators is less than 5 times / h, the energy saving effect is very significant.


2011 ◽  
Vol 347-353 ◽  
pp. 3995-3998
Author(s):  
Shuai Yang ◽  
Lan Xue ◽  
Jian Sheng Cheng

A new type of energy-saving magnetic amplifier controlling current and voltage of inductive load has been designed. The energy-saving magnetic amplifier with two windings wrapped across one iron core column can change impedance of the main winding by means of PWM controlling AC excitation current. The energy-saving magnetic amplifier has not used a special adjustable DC voltage circuit, has overcome disadvantages of complicated manufacturing process for the traditional excitation amplifier.The application shows the energy-saving excitation amplifier can achieve stepless dimming for high pressure sodium lamp to good energy-saving effect. The use cost of excitation amplifier is lower as simple production process, so its promotional value is great.


2019 ◽  
Vol 9 (5) ◽  
pp. 858 ◽  
Author(s):  
Yu Dong ◽  
Xue Cui ◽  
Xunzhi Yin ◽  
Yang Chen ◽  
Haibo Guo

This research evaluates the operational heating and cooling energy consumption of cross-laminated timber (CLT) office buildings in China. The evaluations involve a comparison of the energy consumption of a reference RC structure and CLT system office buildings. Computational simulation results are based on IES-VE 2019 and show that the estimated heating energy saving ratio of CLT buildings in Harbin, Beijing, Shanghai, and Kunming to the reference structure are 11.97%, 22.11%, 30.94%, and 23.30% respectively. However, the CLT buildings consume more energy for cooling in the summer. The results of the research show significantly higher heating energy reductions for CLT buildings in the Cold Region and Severe Cold Regions of China. Thus, the application of the CLT system is better suited to northern China than southern China. The results of the research can be used in further assessment of the use of CLT systems in different climatic regions in China.


2013 ◽  
Vol 448-453 ◽  
pp. 1269-1272
Author(s):  
Zhao Chen ◽  
Li Bai ◽  
Feng Li

In this paper, the software of DeST was used to simulate the heating energy consumption by the year of a typical energy-saving residential building in the city of Changchun. Comparing the energy consumption of the top and bottom,the middle room and the edges rooms ,we get the reasons for the uneven heating and put forward the corresponding solutions, which provide the reference for heating system design.


2020 ◽  
Vol 16 (6) ◽  
pp. 155014772093577
Author(s):  
Zan Yao ◽  
Ying Wang ◽  
Xuesong Qiu

With the rapid development of data centers in smart cities, how to reduce energy consumption and how to raise economic benefits and network performance are becoming an important research subject. In particular, data center networks do not always run at full load, which leads to significant energy consumption. In this article, we focus on the energy-efficient routing problem in software-defined network–based data center networks. For the scenario of in-band control mode of software-defined data centers, we formulate the dual optimal objective of energy-saving and the load balancing between controllers. In order to cope with a large solution space, we design the deep Q-network-based energy-efficient routing algorithm to find the energy-efficient data paths for traffic flow and control paths for switches. The simulation result reveals that the deep Q-network-based energy-efficient routing algorithm only trains part of the states and gets a good energy-saving effect and load balancing in control plane. Compared with the solver and the CERA heuristic algorithm, energy-saving effect of the deep Q-network-based energy-efficient routing algorithm is almost the same as the heuristic algorithm; however, its calculation time is reduced a lot, especially in a large number of flow scenarios; and it is more flexible to design and resolve the multi-objective optimization problem.


2013 ◽  
Vol 357-360 ◽  
pp. 492-498
Author(s):  
Hong Yu ◽  
Hai Jun Sun

In order to assess the human settlements situation of earth construction and analyse Environmental protection and energy saving effect of the earth construction's enclosure-construction, we choose Jinan's earth construction--adobe houses--to conduct the detection and analysis of energy saving and were based on the factual date to calculate enclosure-construction's heat transfer coefficient K and the actual energy consumption to analyses the influential factors of the energy consumption and determine the main part of the energy saving effect of energy consumption based on the Extensive research of the ecological environment and earth construction in Shandong province. The results show that the typical enclosure-structure with good heat saving capacity can maintain the indoor thermal stability. Through the calculation of heat retaining structure, we can know that the tested adobe house's energy consumption is larger than normal house. it suggested that the earth construction has the characteristics of better energy saving and environmental protection. seeing that the factual tested adobe house's lower intensity , bad decoration and imperfection ,we put forward the suitable earth buildings scheme of the construction of new countryside.


2013 ◽  
Vol 732-733 ◽  
pp. 615-619
Author(s):  
Jia Shi Chen ◽  
Zheng Song Wu ◽  
Yang Liu ◽  
Shan Chi Lin

A model reference adaptive control (MRAC) algorithm is proposed to the air-conditioning system of variable air volume (VAV) terminal units (VAV BOX). The study of temperature controlling parameters in room area (Zone) is based on Lyapunov stability theory. We built the simulation model in Matlab to validate the superior controlling performance and good energy saving effect of the algorithm. The research shows that the energy consumption release 60% ~70% in larger room. In modern building, the energy saving and comfort is very important, so the simulation has important engineering practical value.


Sign in / Sign up