Application of Mwp to deep and teleseismic earthquakes

1999 ◽  
Vol 89 (5) ◽  
pp. 1345-1351 ◽  
Author(s):  
Seiji Tsuboi ◽  
Paul M. Whitmore ◽  
Thomas J. Sokolowski

Abstract The broadband moment magnitude Mwp (Tsuboi, et al., 1995) allows for the effective determination of earthquake magnitude by using broadband P waveforms. It was developed to determine moment magnitude of shallow earthquakes around the Japanese Islands for early tsunami warnings. Tsuboi et al. (1995) demonstrated that Mwp shows good agreement with the Mw from Harvard centroid moment tensor (CMT) solutions. In the present study, we show that Mwp is also applicable to deep earthquakes and earthquakes recorded at teleseismic distances. The Mwp proves to be useful for quick, accurate size estimates of earthquakes recorded at both regional and teleseismic distances occurring at any depth.

1996 ◽  
Vol 86 (3) ◽  
pp. 832-842 ◽  
Author(s):  
Akio Katsumata

Abstract The magnitude, MJMA, estimated by the Japan Meteorological Agency (JMA) is generally referred to in Japan for the regional seismicity in the area. MJMA is determined from maximum displacement amplitudes of the total seismic wave traces. For earthquakes shallower than 60 km, MJMA is determined by Tsuboi's formula, and for earthquakes deeper than 60 km, by Katsumata's formula. These relations were designed to give almost the same magnitude value as that of Gutenberg and Richter. We compared MJMA with moment magnitude, MW, which can be calculated from the centroid moment tensor (CMT) solutions. It was found that the average difference between MJMA and MW is not significant for shallow earthquakes in the magnitude range from 5 to 7, but it is significant at a low level for the earthquakes of deeper foci. The averaged difference reaches about 0.4 magnitude units for the focal depth of 600 km. We derived an attenuation function for the maximum displacement amplitude assuming the validity of the moment magnitude. This relation between epicentral distance and amplitude for shallow earthquakes is almost identical to the one calculated from Tsuboi's formula. It is suggested that the estimated attenuation function for deep-focus earthquakes reflects the specific Q and velocity structure that is peculiar to the subduction zone.


2020 ◽  
Vol 91 (6) ◽  
pp. 3195-3207
Author(s):  
Rajiv Kumar ◽  
Ram Bichar Singh Yadav ◽  
Silvia Castellaro

Abstract We present regional earthquake magnitude conversion relations among different magnitude scales (Mw, Ms, mb, ML, and MD) for the Himalayan seismic belt developed from data of local, regional, and international seismological agencies (International Seismological Centre [ISC], National Earthquake Information Centre [NEIC], Global Centroid Moment Tensor Solution [CMT], International Data Centre [IDC], China Earthquake Administration [BJI], and National Centre for Seismology [NDI]). The intra- (within the same magnitude scale) and inter- (with different magnitude scales) magnitude regression relations have been established using the general orthogonal regression and orthogonal distance regression techniques. Results show that the intra-magnitude relations for Mw, Ms, and mb reported by the Global CMT, ISC, and NEIC exhibit 1:1 relationships, whereas ML reported by the IDC, BJI, and NDI deviates from this relationship. The IDC underestimates Ms and mb compared with the ISC, NEIC, and Global CMT; this may be due to different measurement procedures adopted by the IDC agency. The inter-magnitude relations are established between Mw,Global CMT and Ms, mb, and ML reported by the ISC, NEIC, IDC, and NDI, and compared with the previously developed regional and global regression relations. The duration (MD) and local (ML) magnitudes reported by NDI exhibit a 1:1 relationship. The derived magnitude regression relations are expected to support the homogenization of the earthquake catalogs and to improve seismic hazard assessment in this region.


2019 ◽  
Vol 219 (2) ◽  
pp. 1148-1162
Author(s):  
Jiun-Ting Lin ◽  
Wu-Lung Chang ◽  
Diego Melgar ◽  
Amanda Thomas ◽  
Chi-Yu Chiu

SUMMARY We test the feasibility of GPS-based rapid centroid moment tensor (GPS CMT) methods for Taiwan, one of the most earthquake prone areas in the world. In recent years, Taiwan has become a leading developer of seismometer-based earthquake early warning systems, which have successfully been applied to several large events. The rapid determination of earthquake magnitude and focal mechanism, important for a number of rapid response applications, including tsunami warning, is still challenging because of the limitations of near-field inertial recordings. This instrumental issue can be solved by an entirely different observation system: a GPS network. Taiwan is well posed to take advantage of GPS because in the last decade it has developed a very dense network. Thus, in this research, we explore the suitability of the GPS CMT inversion for Taiwan. We retrospectively investigate six moderate to large (Mw6.0 ∼ 7.0) earthquakes and propose a resolution test for our model, we find that the minimum resolvable earthquake magnitude of this system is ∼Mw5.5 (at 5 km depth). Our tests also suggest that the finite fault complexity, often challenging for the near-field methodology, can be ignored under such good station coverage and thus, can provide a fast and robust solution for large earthquake directly from the near field. Our findings help to understand and quantify how the proposed methodology could be implemented in real time and what its contributions could be to the overall earthquake monitoring system.


1969 ◽  
Vol 62 (4) ◽  
pp. 663-670 ◽  
Author(s):  
Lars Carlborg

ABSTRACT Oestrogens administered in lower doses than necessary to induce full cornification of the mouse vagina induce mucification. It was shown previously that the degree of mucification could be estimated by quantitative determination of sialic acids. A suitable parameter for oestrogen assay was the measurement of vaginal sialic acid concentration which exhibited a clear cut dose response curve. Eleven assays of various oestrogens were performed with this method. Their estimated relative potencies were in good agreement with other routine oestrogen assays. A statistically sufficient degree of precision was found. The sensitivity was of the same order, or slightly higher, than the Allen-Doisy test.


1967 ◽  
Vol 13 (6) ◽  
pp. 515-520 ◽  
Author(s):  
Genevieve Farese ◽  
Janice L Schmidt ◽  
Milton Mager

Abstract A completely automated analysis is described for the determination of serum calcium with glyoxal bis (2-hydroxyanil) solution (GBHA). The method is simple and precise, and the data obtained are in good agreement with results obtained by the manual GBHA procedure.


Author(s):  
Emre Kahramanoglu ◽  
Silvia Pennino ◽  
Huseyin Yilmaz

The hydrodynamic characteristics of the planing hulls in particular at the planing regime are completely different from the conventional hull forms and the determination of these characteristics is more complicated. In the present study, calm water hydrodynamic characteristics of planing hulls are investigated using a hybrid method. The hybrid method combines the dynamic trim and sinkage from the Zarnick approach with the Savitsky method in order to calculate the total resistance of the planing hull. Since the obtained dynamic trim and sinkage values by using the original Zarnick approach are not in good agreement with experimental data, an improvement is applied to the hybrid method using a reduction function proposed by Garme. The numerical results obtained by the hybrid and improved hybrid method are compared with each other and available experimental data. The results indicate that the improved hybrid method gives better results compared to the hybrid method, especially for the dynamic trim and resistance. Although the results have some discrepancies with experimental data in terms of resistance, trim and sinkage, the improved hybrid method becomes appealing particularly for the preliminary design stage of the planing hulls.


Sensors ◽  
2021 ◽  
Vol 21 (10) ◽  
pp. 3567
Author(s):  
Beata Szymanska ◽  
Zenon Lukaszewski ◽  
Beata Zelazowska-Rutkowska ◽  
Kinga Hermanowicz-Szamatowicz ◽  
Ewa Gorodkiewicz

Human epididymis protein 4 (HE4) is an ovarian cancer marker. Various cut-off values of the marker in blood are recommended, depending on the method used for its determination. An alternative biosensor for HE4 determination in blood plasma has been developed. It consists of rabbit polyclonal antibody against HE4, covalently attached to a gold chip via cysteamine linker. The biosensor is used with the non-fluidic array SPRi technique. The linear range of the analytical signal response was found to be 2–120 pM, and the biosensor can be used for the determination of the HE4 marker in the plasma of both healthy subjects and ovarian cancer patients after suitable dilution with a PBS buffer. Precision (6–10%) and recovery (101.8–103.5%) were found to be acceptable, and the LOD was equal to 2 pM. The biosensor was validated by the parallel determination of a series of plasma samples from ovarian cancer patients using the Elecsys HE4 test and the developed biosensor, with a good agreement of the results (a Pearson coefficient of 0.989). An example of the diagnostic application of the developed biosensor is given—the influence of ovarian tumor resection on the level of HE4 in blood serum.


Molecules ◽  
2021 ◽  
Vol 26 (12) ◽  
pp. 3627
Author(s):  
Nikola Sakač ◽  
Dubravka Madunić-Čačić ◽  
Dean Marković ◽  
Lucija Hok ◽  
Robert Vianello ◽  
...  

A 1,3-dihexadecyl-1H-benzo[d]imidazol-3-ium-tetraphenylborate (DHBI-TPB) ion-pair implemented in DHBI-TPB surfactant sensor was used for the potentiometric quantification of anionic surfactants in detergents and commercial household care products. The DHBI-TPB ion-pair was characterized by FTIR spectroscopy and computational analysis which revealed a crucial contribution of the C–H∙∙∙π contacts for the optimal complex formation. The DHBI-TPB sensor potentiometric response showed excellent analytical properties and Nernstian slope for SDS (60.1 mV/decade) with LOD 3.2 × 10−7 M; and DBS (58.4 mV/decade) with LOD 6.1 × 10−7 M was obtained. The sensor possesses exceptional resistance to different organic and inorganic interferences in broad pH (2–10) range. DMIC used as a titrant demonstrated superior analytical performances for potentiometric titrations of SDS, compared to other tested cationic surfactants (DMIC > CTAB > CPC > Hyamine 1622). The combination of DHBI-TPB sensor and DMIC was successfully employed to perform titrations of the highly soluble alkane sulfonate homologues. Nonionic surfactants (increased concentration and number of EO groups) had a negative impact on anionic surfactant titration curves and a signal change. The DHBI-TPB sensor was effectively employed for the determination of technical grade anionic surfactants presenting the recoveries from 99.5 to 101.3%. The sensor was applied on twelve powered samples as well as liquid-gel and handwashing home care detergents containing anionic surfactants. The obtained results showed good agreement compared to the outcomes measured by ISE surfactant sensor and a two-phase titration method. The developed DHBI-TPB surfactant sensor could be used for quality control in industry and has great potential in environmental monitoring.


Molecules ◽  
2020 ◽  
Vol 25 (17) ◽  
pp. 3963
Author(s):  
Jizhou Wu ◽  
Jie Ma ◽  
Yuqing Li ◽  
Wenliang Liu ◽  
Peng Li ◽  
...  

This article demonstrates new observation of the high-resolution ro-vibrational bichromatic photoassociation spectra (BPAS) of Cs2 in the 0u+ long-range state below the asymptotes 6S1/2 + 6P1/2. By combining with a modulation spectroscopic technique, precise references of the frequency differences have been engineered through the BPAS, with which the rotational constants of low-lying vibrational levels of the Cs20u+ long-range state have been accurately determined by fitting the frequency differences to the non-rigid-rotor model. The rotational constants for the newly observed seven ro-vibrational levels are summarized and disagreement for the level ῦ = 498 is clarified. The rotational constants of different vibrational levels demonstrate strong perturbations of the related energy structures. A simple analysis is performed and shows good agreement with experimental results.


2009 ◽  
Vol 9 (11) ◽  
pp. 3641-3662 ◽  
Author(s):  
D. Chen ◽  
B. Zhou ◽  
S. Beirle ◽  
L. M. Chen ◽  
T. Wagner

Abstract. Zenith-sky scattered sunlight observations using differential optical absorption spectroscopy (DOAS) technique were carried out in Shanghai, China (31.3° N, 121.5° E) since December 2006. At this polluted urban site, the measurements provided NO2 total columns in the daytime. Here, we present a new method to extract time series of tropospheric vertical column densities (VCDs) of NO2 from these observations. The derived tropospheric NO2 VCDs are important quantities for the estimation of emissions and for the validation of satellite observations. Our method makes use of assumptions on the relative NO2 height profiles and the diurnal variation of stratospheric NO2 VCDs. The main error sources arise from the uncertainties in the estimated stratospheric slant column densities (SCDs) and the determination of tropospheric NO2 air mass factor (AMF). For a polluted site like Shanghai, the accuracy of our method is conservatively estimated to be <25% for solar zenith angle (SZA) lower than 70°. From simultaneously performed long-path DOAS measurements, the NO2 surface concentrations at the same site were observed and the corresponding tropospheric NO2 VCDs were estimated using the assumed seasonal NO2 profiles in the planetary boundary layer (PBL). By making a comparison between the tropospheric NO2 VCDs from zenith-sky and long-path DOAS measurements, it is found that the former provides more realistic information about total tropospheric pollution than the latter, so it's more suitable for satellite data validation. A comparison between the tropospheric NO2 VCDs from ground-based zenith-sky measurements and SCIAMACHY was also made. Satellite validation for a strongly polluted area is highly needed, but exhibits also a great challenge. Our comparison shows good agreement, considering in particular the different spatial resolutions between the two measurements. Remaining systematic deviations are most probably related to the uncertainties of satellite data caused by the assumptions on aerosol properties as well as the layer heights of aerosols and NO2.


Sign in / Sign up

Export Citation Format

Share Document