Dynamic structure-soil-structure interaction

1973 ◽  
Vol 63 (4) ◽  
pp. 1289-1303
Author(s):  
J. Enrique Luco ◽  
Luis Contesse

abstract A study is made of the dynamic interaction, through the soil, between two parallel infinite shear walls placed on rigid foundations. The steady-state response of both structures for a vertically incident SH wave is obtained and compared with the corresponding values resulting from consideration of only one structure. It is found that the additional interaction effects caused by the presence of a second structure are especially important at low frequencies and in the neighborhood of the fixed-base natural frequencies of the second structure. For high frequencies it is sufficient to consider the interaction between each structure and the soil, ignoring the presence of other structures.

2015 ◽  
Vol 744-746 ◽  
pp. 911-914
Author(s):  
Zhao Bo Meng ◽  
Guan Dong Qiao ◽  
Jie Jin

This paper establishes three models using ANSYS, which were timber structure of Guangyue Tower, timber structure-tower base and timber structure-tower base-foundation. The first 3 natural frequencies of timber structure respectively were 0.8524Hz、1.1273 Hz and 1.7426 Hz through modal analysis, which were compared with calculations from code. Lanzhou Wave was chosen to analyze the seismic response of Guangyue Tower, and the amplitudes were adjusted to 55gal and 310gal respectively according to the frequent earthquake and rare earthquake, which were inputted to the above models. As can be seen from the calculations, the maximum displacements of the three models were in the top nodes, and tower base had a greater impact on vibration of timber structure, which could not be ignored in seismic response analysis; considering soil-structure interaction in seismic response analysis could better reflect the actual situation of Guangyue Tower.


2020 ◽  
Vol 8 ◽  
pp. 22-29
Author(s):  
Nasala Dongol ◽  
Prachand Man Pradhan ◽  
Suman Manandhar

This study states that the effects of soil structure interaction on the Reinforced Concrete (RC) framed structures is directly influenced by the soil properties of the site. Here, one preexisting structure is taken for the study. The building is a hospital building with two underground basements. Taking into account the actual soil condition of building site, this study provides idea on the soil structure interaction on the structure The properties of springs are calculated from different standard penetration test (SPT) values, Poisson’s ratio and elasticity of soil along the depth of the soil. Entire soil-foundation-structure system is modelled and analyzed using spring approach. Static analysis, response spectrum analysis and pushover analysis (PA) are done in order to find the variations in natural periods, base shears and deflections of the structures by incorporating soil flexibility as compared to structures with conventional fixed base. Pushover analysis is done to evaluate the performance of the structure when modelled in fixed base and spring base system.


2020 ◽  
Vol 10 (23) ◽  
pp. 8357
Author(s):  
Ibrahim Oz ◽  
Sevket Murat Senel ◽  
Mehmet Palanci ◽  
Ali Kalkan

Reconnaissance studies performed after destructive earthquakes have shown that seismic performance of existing buildings, especially constructed on weak soils, is significantly low. This situation implies the negative effects of soil-structure interaction on the seismic performance of buildings. In order to investigate these effects, 40 existing buildings from Turkey were selected and nonlinear models were constructed by considering fixed-base and stiff, moderate and soft soil conditions. Buildings designed before and after Turkish Earthquake code of 1998 were grouped as old and new buildings, respectively. Different soil conditions classified according to shear wave velocities were reflected by using substructure method. Inelastic deformation demands were obtained by using nonlinear time history analysis and 20 real acceleration records selected from major earthquakes were used. The results have shown that soil-structure interaction, especially in soft soil cases, significantly affects the seismic response of old buildings. The most significant increase in drift demands occurred in first stories and the results corresponding to fixed-base, stiff and moderate cases are closer to each other with respect to soft soil cases. Distribution of results has indicated that effect of soil-structure interaction on the seismic performance of new buildings is limited with respect to old buildings.


2017 ◽  
Vol 20 (11) ◽  
pp. 1712-1726
Author(s):  
Farhad Behnamfar ◽  
Seyyed Mohammad Mirhosseini ◽  
Hossein Alibabaei

A common assumption when analyzing a structure for earthquake forces is that the building is positively attached to a rigid ground so that it can sustain possible tensile forces without being detached, or uplifted, from its bearing points. Considering the facts that almost no tension can be transferred between a surface foundation and soil and soft soils interact with the supported structure during earthquakes, in this research, the effects of uplift and soil–structure interaction on nonlinear seismic response of structures are evaluated. Several reinforced concrete and steel structures under different suits of consistent ground motions are considered. The base of the buildings is modeled with vertical no-tension springs being nonlinear in compression. The total soil–structure interaction system is modeled within OpenSees, and the seismic behavior is evaluated using a nonlinear dynamic analysis. The nonlinear responses of buildings are determined and compared between three cases: fixed base, flexible base without uplift, and flexible base with uplift. The cases for which uplift in conjunction with soil–structure interaction should be considered are identified.


Author(s):  
David K. Nakaki ◽  
Philip S. Hashimoto ◽  
James J. Johnson ◽  
Yahya Bayraktarli ◽  
Olivier Zuchuat

Probabilistic seismic soil-structure interaction (SSI) analysis was performed for the Mu¨hleberg Nuclear Power Plant Reactor and SUSAN Buildings in support of the seismic probabilistic saftety assessment of the plant. An efficient hybrid method, employing computer programs SASSI2000 and CLASSI presented in a companion paper, was used in this analysis. The method takes advantage of the capability of SASSI2000 to analyze embedded structures with irregular geometry and the computational efficiency of CLASSI to rapidly perform the SSI response analysis of large structure models. Fixed base finite element models of the buildings were first developed from which the structure geometry, nodal masses, natural frequencies, and mode shapes were extracted. The structure embedments were modeled using SASSI2000. Impedance functions and scattering vectors were calculated by imposing rigid body constraints to the embedded foundation. The fixed base structure dynamic properties and the foundation impedances and scattering functions were input to CLASSI to perform the response analysis. The probabilistic analysis was performed following the Latin Hypercube Simulation (LHS) approach documented in NUREG/CR-2015. Variables defined by probability distributions were sampled according to a stratified sampling approach. The combination of the parameters for each simulation was determined by Latin Hypercube experimental design. Variables in the LHS included the earthquake ground acceleration time histories, structure stiffness and damping, and soil stiffness and damping. Thirty response simulations were performed using CLASSI in which the variable values were randomly selected. The use of CLASSI has the advantage that the response analysis simulations can be executed in a fraction of the time that would be required with SASSI2000 alone. For each simulation, in-structure response spectra (ISRS) were calculated at selected locations in the buildings. Probabilistic distributions, described by the median and 84th percentile response spectra, were calculated from the thirty simulations. The probabilistic ISRS are subsequently used in the seismic fragility evaluations of selected essential equipment.