scholarly journals Determination of Lactoferrin in Goat Milk by HPLC Method

2009 ◽  
Vol 27 (Special Issue 1) ◽  
pp. S102-S104 ◽  
Author(s):  
M. Dračková ◽  
I. Borkovcová ◽  
B. Janštová ◽  
M. Naiserová ◽  
H. Přidalová ◽  
...  

The aim of this study was the determination of lactoferrin in goat milk using HPLC method. Milk samples were collected at a goat farm in the South Moravia Region, the Czech Republic. It were established bulk tank samples of raw milk (<I>n</I> = 24) and pasteurised milk (<I>n</I>n = 27) that were collected during lactation. Lactoferrin contents were analysed by reverse phase high-performance liquid chromatography (RP-HPLC) with diode-array detector PDA 2996. Detection was carried out at the wavelength 205 nm. The average concentration of lactoferrin in goat milk was 120 ± 18 &mu;g/ml. The lactoferrin content was increasing within the lactation period in the ranges of 98 ± 170 &mu;g/ml in April to 149 ± 19 &mu;g/ml in November. The heat treatment (pasteurisation at 72°C for 20 s) resulted in no significant effect on the lactoferrin content. No statistically significant differences (<I>P</I> = 0.05) were found between the values of raw and pasteurised goat milk.

2016 ◽  
Vol 8 (30) ◽  
pp. 5949-5956 ◽  
Author(s):  
Soumia Boulahlib ◽  
Ali Boudina ◽  
Kahina Si-Ahmed ◽  
Yassine Bessekhouad ◽  
Mohamed Trari

In this study, a rapid and simple method based on reversed-phase high performance liquid chromatography (RP-HPLC) using a photodiode array detector (PDA) for the simultaneous analysis of five pollutants including aniline and its degradation products, para-aminophenol, meta-aminophenol, ortho-aminophenol and phenol, was developed.


Author(s):  
Yan Xiong ◽  
Yong-Hong Liu ◽  
Jian-Sha Li ◽  
Yu-Ying Zhang ◽  
Jing Zhang ◽  
...  

Abstract A simple high performance liquid chromatography (HPLC) method was developed and validated for the determination of coumarin-3-carboxylic acid analogues (C3AA) in rat plasma and a preliminary study on pharmacokinetics. Ferulic acid (FA) was used as the internal standard substance, and coumarin-3-carboxylic acid (C3A) was used as a substitute for quantitative C3AA. After protein precipitation with methanol, the satisfactory separation was achieved on an ODS2 column when the temperature was maintained at 30 ± 2°C. The correlation coefficient r in the C3A linear equation is equal to 0.9990. Pharmacokinetic parameters for t1/2, Tmax, Cmax, area under the curve (AUC)0-t, average residence time (MRT), apparent volume of distribution (V z/F) and clearance (Cl/F) were 1.89 ± 0.03 h, 0.39 ± 0.14 h, 1.81 ± 0.10 g· mL−1 ·h, 7.88 ± 0.24 g·mL−1·h, 3.23 ± 0.14 h, 0.43 ± 0.03 (mg·kg−1)·(g·mL−1)−1·h−1, respectively. The high performance liquid chromatography-photo diode array detector (HPLC-PDA) method established in this study can be used to separate and determine the content of C3AA in plasma of rats after 60% ethanol extraction by gavage. The plasma concentration-time curve and pharmacokinetic parameters reflect the absorption of C3AA in rat blood after oral administration to some extent.


2016 ◽  
Vol 9 (1) ◽  
pp. 54
Author(s):  
Megha Sharma ◽  
Neeraj Mahindroo

Objective: The objective of the present study was to develop and validate a novel stability indicating reverse phase-high performance liquid chromatography (RP-HPLC) method for determination of β-acetyldigoxin, an active pharmaceutical ingredient (API).Methods: The chromatographic separation was carried out on Agilent Technologies 1200 series HPLC system equipped with photo diode array detector and C-18 (4.6x250 mm, 5 µ) column. The mobile phase consisted of water: acetonitrile (65:35 v/v), delivered at a flow rate of 1.5 ml/min and eluents were monitored at 225 nm.Results: The retention time of β-acetyldigoxin was 9.2 min. The method was found to be linear (R2= 0.9995) in the range of 31.25-500 µg/ml. The accuracy studies showed the mean percent recovery of 101.02%. LOD and LOQ were observed to be 0.289 µg/ml and 0.965 µg/ml, respectively. The method was found to be robust and system suitability testing was also performed. Forced degradation analysis was carried out under acidic, alkaline, oxidative and photolytic stress conditions. Significant degradation was observed under tested conditions, except for oxidative condition. The method was able to separate all the degradation products within runtime of 20 min and was able to determine β-acetyldigoxin unequivocally in presence of degradation products.Conclusion: The novel, economic, rapid and simple method for analysis of β-acetyldigoxin is reported. The developed method is suitable for routine quality control and its determination as API, and in pharmaceutical formulations and stability study samples.


2013 ◽  
Vol 96 (5) ◽  
pp. 1059-1064 ◽  
Author(s):  
You-Shin Shim ◽  
Seunghee Kim ◽  
Dongwon Seo ◽  
Masahito Ito ◽  
Hiroaki Nakagawa ◽  
...  

Abstract A rapid method for the simultaneous determination of flavonol aglycones in food using ultra-high-performance LC (u-HPLC) coupled with a heating-block acidic hydrolysis method was validated in terms of precision, accuracy, and linearity. The u-HPLC separation was performed on an RP C18 column (particle size 2 μm id, 2 mm, length 100 mm) with a photodiode array detector. The LOD and LOQ of the u-HPLC analyses were 0.15 and 0.47 mg/kg for myricetin, 0.09 and 0.28 mg/kg for quercetin, 0.16 and 0.49 mg/kg for kaempferol, and 0.08 and 0.25 mg/kg for isorhamnetin. The intraday and interday precisions of the individual flavonol aglycones were less than 9.31%. All calibration curves exhibited good linearity (r2 = 0.99) within the tested ranges. Total run time of u-HPLC was 13 min. The rapid u-HPLC method presented herein significantly improved the speed, sensitivity, and resolution of the analyses of myricetin, quercetin, kaempferol, and isorhamnetin in food.


2015 ◽  
Vol 98 (2) ◽  
pp. 390-396 ◽  
Author(s):  
Yang Chen ◽  
Ravinder M Reddy ◽  
Wenjing Li ◽  
Ramesh R Yettlla ◽  
Salvador Lopez ◽  
...  

Abstract An HPLC method for simultaneous determination of vitamins A and D3 in fluid milk was developed and validated. Saponification and extraction conditions were studied for optimum recovery and simplicity. An RP HPLC system equipped with a C18 column and diode array detector was used for quantitation. The method was subjected to a single-laboratory validation using skim, 2% fat, and whole milksamples at concentrations of 50, 100, and 200% of the recommended fortification levels for vitamins A and D3 for Grade “A” fluid milk. The method quantitation limits for vitamins A and D3 were 0.0072 and 0.0026 μg/mL,respectively. Average recoveries between 94 and 110%and SD values ranging from 2.7 to 6.9% were obtainedfor both vitamins A and D3. The accuracy of the method was evaluated using a National Institute of Standards and Technology standard reference material (1849a) and proficiency test samples.


2021 ◽  
Vol 20 (11) ◽  
pp. 2371-2379
Author(s):  
Yanqin Zhu ◽  
Qinhong Yin ◽  
Yaling Yang

Purpose: To develop, validate and compare two chromatographic methods - high performance liquid chromatography with diode array detector ((HPLC-DAD) and high performance liquid chromatography with ultraviolet detection (UPLC-UV) for the effective analysis of polyphenols in Moringa oleifera leaves.Methods: HPLC-DAD and UPLC-UV methods were applied for the accurate determination of eleven major polyphenols in Moringa oleifera leaves. The chromatographic conditions of the eleven polyphenols was determined on two C18 column by gradient elution with 0.5 % phosphoric acid solution -acetonitrile as the eluate, and at a flow rate of 1.0 and 0.5 mL/min for HPLC-DAD and UPLC-UV methods, respectively. Detector parameter of UPLC-UV was fixed at 203 nm. The assay methods were validated systematically.Results: The instrumental methods (HPLC-DAD and UPLC-UV) had good linearity, precision,repeatability and recovery. For both methods, quantification limits of UPLC-UV (0.057 - 0.363 μg/mL) were lower than those of UPLC-UV (0.094 - 1.532 μg/mL). The UPLC method with a shorter running time and more sensitive detection was applied in comparing to the HPLC method. After optimization and evaluation, the baseline of 11 compounds was separated effectively within 68 and 34 min, respectively.Conclusion: The developed HPLC-DAD and UPLC-UV assays were successfully utilized for thesimultaneous analysis of eleven major polyphenols and can readily be utilized as quality control tools for Moringa oleifera leaves in China, with UPLC-UV method showing better separation, lower organic solvent usage and shorter analytical period.


Author(s):  
Saniye Özcan ◽  
Serkan Levent ◽  
Nafiz Öncü Can

: The alkyl esters of p-hydroxybenzoic acid at the C-4 position, “the parabens,” including methyl, ethyl, propyl, and butyl, are widely used as antimicrobial preservatives in foods, cosmetics, and pharmaceuticals. Official regulations on the use of these compounds make their analysis essential for the estimation of their exposure. On this basis, the presented study was realized to develop a simple, selective and cheap high-performance liquid chromatographic method for the quantitative determination of methyl paraben (MP), ethyl paraben (EP), n-propyl paraben (NPP), isopropyl paraben (IPP), n-butyl paraben (NBP), isobutyl paraben (IBP) and benzyl paraben (BP) in pharmaceuticals and cosmetic products. The chromatographic separation of the analytes was achieved under flow rate gradient elution conditions using a C18-bonded core-shell silica particle column (2.6 μm particle size, 150 × 3.0 mm from Phenomenex Co.). The samples were injected into the system as aliquots of 1.0 μL, and the compounds were detected by using a photodiode array detector set at 254 nm wavelength. With this technique, seven paraben derivatives can be determined in the concentration range of 250-2000 ng/mL. The recovery of the method is in the range of 99.95-13.84%, and the RSD is at a maximum value of 3.95%. The proposed method was fully validated and successfully applied to different pharmaceutical and cosmetic samples (n=16), including syrups, suspensions, oral sprays, gels, etc. At least one paraben derivative was detected in six of the samples, and was determined quantitatively. The maximum amount of a paraben derivative found in the analyzed samples is 321.7 ng/mL, which was MP. To the best of our knowledge, this is the first LC method, which is applicable both on pharmaceutical and cosmetic samples.


2013 ◽  
Vol 78 (6) ◽  
pp. 839-850 ◽  
Author(s):  
Igor Jajic ◽  
Sasa Krstovic ◽  
Dragan Glamocic ◽  
Sandra Jaksic ◽  
Biljana Abramovic

The subject of this study is the validation of a high-performance liquid chromatography method for the analysis of amino acids in feed. The contents of amino acids were determined in maize, soybean, soybean meal, as well as in their mixtures enriched with different amounts of methionine, threonine and lysine. The method involves the acid hydrolysis of the sample (6 h at 150?C), automated derivatisation of amino acids with the aid of o-phthaldialdehyde and 9-fluorenylmethyl chloroformate reagents, separation on the ZORBAX Eclipse-AAA column, and detection using a diode-array detector. The method is characterized by high specificity (the difference between the retention times of the feed samples and standard mixtures are below 1.7 %), wide linear range (from 10 to 1000 nmol cm-3, r2 = 0.9999), high accuracy (recovery 93.3-109.4 %), and the precision of the results (RSD below 4.14 % in case of repeatability and below 4.57 % in the case of intermediate precision). The limit of detection and the limit of quantification are in the range 0.004-1.258 ?g cm-3 and 0.011-5.272 ?g cm-3, respectively. The results demonstrate that the procedure can be used as a method for the determination of the composition of primary amino acids of feed proteins.


Author(s):  
SYED IBRAHIM BAJE ◽  
B. JYOTHI ◽  
N. MADHAVI

Objective: The objective of the present study was to develop and validate a novel reverse phase high performance liquid chromatographic (RP-HPLC) method, for simultaneous determination of ritonavir (RIT), ombitasvir (OMB) and paritaprevir (PAR) in bulk mixtures, and in tablets. Methods: Determination of the drugs ritonavir (RIT), ombitasvir (OMB), and paritaprevir (PAR), was carried out applying Hypersil BDS C18 column (250 mm X 4.6 mm i.e., 5 µm particle size), with photodiode array detector at λmax of 254 nm. The mobile phase applied for the current study composed of two solvents, i.e. A (0.01N % w/v potassium di-hydrogen orthophosphate buffer, pH 3.0 adjusted with dilute orthophosphoric acid) and B (acetonitrile). The mobile phase was pumped at a flow rate of 1.0 ml/min in the isocratic mode. The validation study with respect to specificity, linearity, precision, accuracy, and robustness, limit of detection (LOD) and limit of quantification (LOQ) was carried out employing the ICH guidelines. Results: Ritonavir, ombitasvir, and paritaprevir showed linearity of response between 12.5-75 μg/ml for ritonavir, 3.125-18.75 µg/ml for ombitasvir and 18.75–112.5 µg/ml for paritaprevir, with a correlation coefficient (R2) 0.999, 0.999,0.999 for RIT, OMB, and PAR respectively. The % recovery obtained was 99.82±0.14 % RIT, OMB 100.03±0.96 % and for 99.96±0.26 % PAR. The LOD and LOQ values for RIT, OMB, PAR were obtained to be 0.02, 0.019and0.02, µg/ml and 0.07, 0.06 and 0.07 µg/ml, respectively. The method also exhibits good robustness for different chromatographic conditions like wavelength, flow rate, mobile phase, and injection volume. Conclusion: The method was successfully employed, for the quantification of RIT, OMB, and PAR, in the quality control of in-house developed tablets, and can be applied for the industrial use.


2010 ◽  
Vol 93 (3) ◽  
pp. 855-861 ◽  
Author(s):  
Qi Yang ◽  
Feng Zhang ◽  
Shou-Hong Gao ◽  
Lian-Na Sun ◽  
Wan-Sheng Chen

Abstract An HPLC method combined with a photodiode array detector was developed for quantitative determination of five bioactive compounds that belong to two subclasses, including limonin, phellodendrine, jatrorrhizine, palmatine, and berberine in Cortex Phellodendri. The analysis was performed on an Agilent Diamonsil C18 column (4.6 250 mm, 5 m) using a gradient of acetonitrile and 0.3 aqueous diethylamine phosphate (v/v), a flow rate of 0.8 mL/min, and a detection wavelength of 220 nm. The calibration curve was linear over the range of 2.5100.0 g/mL for both phellodendrine and jatrorrhizine, 5.0200.0 g/mL for palmatine, and 7.5300.0 g/mL for both berberine and limonin. The average recoveries ranged from 97.56 to 102.53 with RSD 1.00. Samples from different geographical locations were analyzed to evaluate the applicability of the established method, and the results indicated that the method was efficient, sensitive, and reliable for determining limonin and four alkaloids in Cortex Phellodendri.


Sign in / Sign up

Export Citation Format

Share Document