scholarly journals Automatic guidance systems in agricultural machinery as a tool for drivers’ mental strain and workload relief 

2017 ◽  
Vol 63 (Special Issue) ◽  
pp. S66-S72
Author(s):  
Kvíz Zděnek ◽  
Kroulík Milan

This article evaluates agricultural operator´s stress, mental strain and generally fighting with driving difficulties during operating agricultural machinery sets by means of a heart rate indicator. Different drivers driving different tractors with implements were chosen and evaluated during different field jobs, namely soil tillage and sowing. Machinery position on the field was precisely monitored by a GPS receiver and the heart beat rate was observed by means of a chest belt special device with a heart rate sensor. The output data from the sensors were monitored during conventional manual steering of the tractor-implement set and also when using the complete automatic guidance steering without any driver´s intervention to steering wheel – all by using the DGPS guidance signal. The data were further processed with a special software for the heart rate sensor and detailed statistical evaluation was performed. All described trials were measured at different farms in the Czech Republic. The final outcomes from the experiment showed a statistically significant difference between two experimental variants and confirm our hypothesis that the guidance systems bring a great benefit for drivers concerning mental strain and relief of their workload.

Author(s):  
A. E. Chernikova ◽  
Yu. P. Potekhina

Introduction. An osteopathic examination determines the rate, the amplitude and the strength of the main rhythms (cardiac, respiratory and cranial). However, there are relatively few studies in the available literature dedicated to the influence of osteopathic correction (OC) on the characteristics of these rhythms.Goal of research — to study the influence of OC on the rate characteristics of various rhythms of the human body.Materials and methods. 88 adult osteopathic patients aged from 18 to 81 years were examined, among them 30 men and 58 women. All patients received general osteopathic examination. The rate of the cranial rhythm (RCR), respiratory rate (RR) heart rate (HR), the mobility of the nervous processes (MNP) and the connective tissue mobility (CTM) were assessed before and after the OC session.Results. Since age varied greatly in the examined group, a correlation analysis of age-related changes of the assessed rhythms was carried out. Only the CTM correlated with age (r=–0,28; p<0,05) in a statistically significant way. The rank dispersion analysis of Kruskal–Wallis also showed statistically significant difference in this indicator in different age groups (p=0,043). With the increase of years, the CTM decreases gradually. After the OC, the CTM, increased in a statistically significant way (p<0,0001). The RCR varied from 5 to 12 cycles/min in the examined group, which corresponded to the norm. After the OC, the RCR has increased in a statistically significant way (p<0,0001), the MNP has also increased (p<0,0001). The initial heart rate in the subjects varied from 56 to 94 beats/min, and in 15 % it exceeded the norm. After the OC the heart rate corresponded to the norm in all patients. The heart rate and the respiratory rate significantly decreased after the OC (р<0,0001).Conclusion. The described biorhythm changes after the OC session may be indicative of the improvement of the nervous regulation, of the normalization of the autonomic balance, of the improvement of the biomechanical properties of body tissues and of the increase of their mobility. The assessed parameters can be measured quickly without any additional equipment and can be used in order to study the results of the OC.


Author(s):  
Antti Vehkaoja ◽  
Timo Salpavaara ◽  
Jarmo Verho ◽  
Jukka Lekkala
Keyword(s):  

Healthcare ◽  
2021 ◽  
Vol 9 (7) ◽  
pp. 918
Author(s):  
Hansen Li ◽  
Xing Zhang ◽  
Shilin Bi ◽  
Yang Cao ◽  
Guodong Zhang

Reducing the burden of pain via greenspace exposure is a rising research topic. However, insufficient evidence has been found in relation to the environmental effect itself. Residential greenspace, as a convenient but limited natural environment for urban dwellers, has benefits and services yet to be discovered. Therefore, the current study recruited 24 young adults to evaluate the effects of physical visit to, or image viewing of, residential greenspace on pain perception and related psychophysiological outcomes, via simulated pain. Pain threshold and tolerance were recorded via the level of pain stimuli, and pain intensity was evaluated using the Visual Analog Scale (VAS). The state scale of the State–Trait Anxiety Inventory (STAI-S) and two adjective pairs were employed to measure the state anxiety and subjective stress, respectively. Meanwhile, heart rate (HR), heart rate variability (HRV), and blood pressure (BP) were measured to investigate physiological responses. Besides, Scenic Beauty Estimation (SBE) was also employed to assess participants’ preference regarding the experimental environments. The results revealed that visiting the greenspace significantly increased the pain threshold and tolerance, while no significant effect was observed for image viewing. On the other hand, no significant difference was observed in pain-related psychophysiological indices between the experimental settings, but significantly negative associations were found between the scores of SBE and subjective stress and state anxiety. In conclusion, the current study brings experimental evidence of improving pain experience via residential greenspace exposure, while the related psychophysiological benefits require further investigation.


2021 ◽  
pp. 112067212110233
Author(s):  
Marcelina Sobczak ◽  
Magdalena Asejczyk ◽  
Malwina Geniusz

Objectives: The main goal of this research was to determine the differences between the values of intraocular pressure (IOP) in the supine and sitting positions, and to assess the effect of age and cardiovascular parameters. Methods: Seventy-two healthy adults were enrolled and classified into age groups: 20–30 years (group A), 31–40 years (group B), and 41–71 years (group C). Corneal biometry and cardiovascular parameters, such as heart rate (HR), were measured. IOP measurements were taken in the sitting position (IOPS) and in the supine position (IOPL) using the iCare® Pro tonometer. Results: A significant difference between the IOPS and IOPL in the entire cohort was found ( p < 0.001). Regarding the age subgroups, a significant difference ( p < 0.001) between the IOPS and IOPL was obtained in group A (2.6 ± 1.6 mmHg) and group C (1.5 ± 1.3 mmHg). There were no significant differences in the IOPS between groups. The highest IOP values were obtained for group A. The correlations between HR and IOPS are statistically significant for group A and group B, and for HR and IOPL-S for group B only. Multivariate analysis showed that HR has a significant influence on the difference in IOP in the two body positions. Conclusion: A statistically significant difference between the effect of age and the values of IOPS and IOPL was shown. Cardiovascular parameters showed some relevant statistical dependencies, but with a rather marginal significance in young people. The influence of body position for the measurement of IOP for healthy subjects does not seem to matter, despite the fact that there are some dependencies that are statistically significant.


2021 ◽  
pp. 194589242198915
Author(s):  
David C. Moffatt ◽  
Robert A. McQuitty ◽  
Alex E. Wright ◽  
Tawanda S. Kamucheka ◽  
Ali L. Haider ◽  
...  

Background Previous studies and meta analyses have led to incongruent and incomplete results respectively when total intravenous anesthesia (TIVA) and inhalational anesthesia (IA) are compared in endoscopic sinus surgeries in regards to intraoperative bleeding and visibility. Objective To perform a more comprehensive meta-analysis on randomized controlled trial (RCTs) comparing TIVA with IA in endoscopic sinus surgery to evaluate their effects on intraoperative bleeding and visibility. Methods A systematic review and meta-analysis of studies comparing TIVA and IA in endoscopic sinus surgery for chronic rhinosinusitis was completed in May 2020. Utilizing databases, articles were systematically screened for analysis and 19 studies met our inclusion criteria. The primary outcome included intraoperative visibility scores combining Boezaart, Wormald and Visual Analogue Scale (VAS). Secondary outcomes included rate of blood loss (mL/kg/min), estimated total blood loss (mL), Boezaart, Wormald scores, VAS, heart rate, and mean arterial pressure (MAP). Results 19 RCTs with 1,010 patients were analyzed. TIVA had a significantly lower intraoperative bleeding score indicating better endoscopic visibility (Boezaart, VAS, and Wormald) than IA (−0.514, p = 0.020). IA had a significantly higher average rate of blood loss than TIVA by 0.563 mL/kg/min (p = 0.016). Estimated total blood loss was significantly lower in TIVA than IA (−0.853 mL, p = 0.002). There were no significant differences between TIVA and IA in the mean heart rate (−0.225, p = 0.63) and MAP values (−0.126, p = 0.634). The subgroup analyses revealed no significant difference between TIVA and IA when remifentanil was not utilized and whenever desflurane was the IA agent. Conclusion TIVA seemed to have superior intraoperative visibility scores and blood loss during endoscopic sinus surgery when compared to IA. However, the results are not consistent when stratifying the results based on the use of remifentanil and different inhaled anesthetics. Therefore, the conclusion cannot be made that one approach is superior to the other.


1995 ◽  
Vol 82 (3) ◽  
pp. 641-648 ◽  
Author(s):  
T. W. Hui ◽  
T. G. Short ◽  
W. Hong ◽  
T. Suen ◽  
T. Gin ◽  
...  

Background Propofol and ketamine may be paired for anesthesia induction and for total intravenous anesthesia. The nature of any sedative interactions occurring between propofol and ketamine are unknown. The combination when used for anesthesia induction in female patients was studied. Methods Quantal dose-response curves were determined in 180 female patients to whom the drugs were administered individually and in combination. Two minutes after administering the drugs, two endpoints were assessed. First, loss of response to verbal command (hypnosis) and then, in those who failed to respond to this endpoint, loss of response to a 5-s transcutaneous tetanus (anesthesia). Interactions were analyzed by fitting the data to a mathematical model in which response was analyzed in terms of the doses of the two drugs and an additional term included to describe nonadditive interactions. The incidences of apnea, arterial pressure, and heart rate changes during the first 5 min were recorded. Results At the hypnotic endpoint, the ED50s were 1.10 mg/kg propofol (95% CIs 0.93-1.27), 0.39 mg/kg ketamine (95% CIs 0.27-0.46), and the combination of 0.63 mg/kg propofol and 0.21 mg/kg ketamine (95% CIs 0.53/0.18-0.73/0.24). At the anesthetic endpoint, the ED50s were 1.85 mg/kg propofol (95% CIs 1.58-2.36) 0.66 mg/kg ketamine (95% CIs 0.58-0.77), and the combination of 1.05 mg/kg propofol and 0.35 mg/kg ketamine (95% CIs 0.88/0.29-1.27/0.42). The effects were additive at both endpoints; there was no evidence of an interaction. The ED50s for apnea were 1.61 mg/kg propofol (95% CIs 1.39-1.94), greater than 0.85 mg/kg ketamine and for the combination 1.50 mg/kg propofol and 0.50 mg/kg ketamine (95% CIs 1.15/0.38-3.09/1.03). The addition of ketamine did not significantly alter the ED50 for apnea of propofol. There was a significant difference in the arterial pressures among the three groups (P &lt; 0.001). Using the combination, the cardiostimulant effects of ketamine balanced the cardiodepressant effects of propofol. There was no change in arterial pressure or heart rate after the noxious stimulus. Conclusions When using the combination, doses were additive at hypnotic and anesthetic endpoints. Ketamine had no influence on the incidence of apnea after propofol, and the net hemodynamic effects were minimal.


Author(s):  
Zhouchen Ma ◽  
Cheng Chen ◽  
Min Wang ◽  
Yang Zhao ◽  
Liang Ying ◽  
...  
Keyword(s):  

Author(s):  
Yibo Zhu ◽  
Rasik R Jankay ◽  
Laura C Pieratt ◽  
Ranjana K. Mehta

Extensive research has been conducted to study the effects of physical and sleep related fatigue on occupational health and safety. However, fatigue is a complex multidimensional construct, that is task- and occupation-dependent, and our knowledge on how to measure this complex construct is limited. A scoping review was conducted to: 1) review sensors and their metrics currently employed in occupational fatigue studies, 2) identify overlap between sensors and associated metrics that can be leveraged to assess comprehensive fatigue, 3) investigating the effectiveness of the sensors/metrics, and 4) recommended potential sensor/metric combinations to evaluate comprehensive fatigue. 512 unique abstracts were identified through Ovid-MEDLINE, MEDLINE, Embase and Cinal databases and application of the inclusion/exclusion criteria resulted in 27 articles that were included for the review. Heart rate sensors and actigraphs were identified to be the most suitable devices to study comprehensive fatigue. Heart rate trend within the heart rate sensor, and sleep length and sleep efficiency within actigraphs were found to be the most popular and reliable metrics for measuring occupational fatigue.


2010 ◽  
Vol 68 ◽  
pp. 480-480
Author(s):  
C Ward ◽  
J Teoh ◽  
M Grubb ◽  
J Crowe ◽  
B Hayes-Gill ◽  
...  

2005 ◽  
Vol 110 (1) ◽  
pp. 117-123 ◽  
Author(s):  
Jan Börgel ◽  
Tino Schulz ◽  
Nina K. Bartels ◽  
Jörg T. Epplen ◽  
Nikolaus Büchner ◽  
...  

OSA (obstructive sleep apnoea) stimulates sympathetic nervous activity and elevates resting HR (heart rate) and BP (blood pressure). In the present study in a cohort of 309 untreated OSA patients, the resting HR and BP during the daytime were correlated with AHI (apnoea/hypopnea index) and compared with patients with R389R (n=162), R389G (n=125) and G389G (n=22) genotypes of the β1-adrenoreceptor R389G polymorphism. We analysed the impact of the genotype on the decline of HR and BP in a subgroup of 148 patients (R389R, n=86; R389G, n=54; G389G, n=8) during a 6-month follow-up period under CPAP (continuous positive airway pressure) therapy during which cardiovascular medication remained unchanged. In untreated OSA patients, we found an independent relationship between AHI and resting HR (β=0.096, P<0.001), systolic BP (β=0.09, P=0.021) and diastolic BP (β=0.059, P=0.016). The resting HR/BP, however, did not differ among carriers with the R389R, R389G and G389G genotypes. CPAP therapy significantly reduced HR [−2.5 (−1.1 to −4.0) beats/min; values are mean difference (95% confidence intervals)] and diastolic BP [−3.2 (−1.5 to −5.0) mmHg]. The decline in HR was more significantly pronounced in the R389R group compared with the Gly389 carriers [−4.1 (−2.3 to −5.9) beats/min (P<0.001) compared with −0.2 (2.1 to −2.6) beats/min (P=0.854) respectively; Student's t test between groups, P=0.008]. Diastolic BP was decreased significantly (P<0.001) only in Gly389 carriers (R389G or G389G) compared with R389R carriers [−5.0 (−2.3 to −7.6) mmHg compared with −2.0 (0.4 to −4.3) mmHg respectively]. ANOVA revealed a significant difference (P=0.023) in HR reduction between the three genotypes [−4.1 (±8.4) beats/min for R389R, −0.5 (±9.3) beats/min for R389G and +1.9 (±7.2) beats/min for G389G]. In conclusion, although the R389G polymorphism of the β1-adrenoceptor gene did not influence resting HR or BP in untreated OSA patients, it may modify the beneficial effects of CPAP therapy on these parameters.


Sign in / Sign up

Export Citation Format

Share Document