scholarly journals Application of FT NIR spectroscopy in the determination of basic chemical composition of pork and beef

2011 ◽  
Vol 51 (No. 8) ◽  
pp. 361-368 ◽  
Author(s):  
J. Mlček ◽  
K. Šustová ◽  
J. Simeonovová

The objective of this paper was to determine basic components of pork and beef (fat, protein, water content) using FT NIR spectroscopy. The samples were analysed on an FT NIR Nicolet Antaris device in a reflec-tance regimen. Reference results from classical analyses were used for the calibration of the device. Calibration models were created using PLS algorithm (method of partial least squares) and verified by cross-validation. High correlation coefficients (R) of calibration were calculated (fat 0.998; protein 0.976; water 0.994), and subsequently of validation as well (fat 0.997; protein 0.970; water 0.993) and very low standard deviations of the calibration and validation (SEC, SEP). No statistically significant differences between the reference and predicted values of determination were detected in Z-test. According to the published results, the NIRS method has a high potential to replace an expensive and time demanding chemical analysis of meat composition.  

2011 ◽  
Vol 675-677 ◽  
pp. 329-332
Author(s):  
Sheng Yao ◽  
Mian Xing ◽  
Yi Fei Jiang ◽  
Guo Feng Wu ◽  
Jun Wen Pu

The aim of this work was to study the ability of NIR spectroscopy to determine holocellulose and alpha-cellulose contents in triploid clones of Populus tomentosa. For this purpose 90 trees with five families in different planting density grown in Shandong were analyzed. Calibration models were developed from wet chemical and NIR data using partial least squares (PLS) regression. High coefficients of determination (R2) and low root mean square errors of cross-validation (RMSECV) were obtained for holocellulose (R2 = 0.7805, RMSECV =0.652) and alpha-cellulose (R2 = 0.8702, RMSECV = 0.548) from wood meal. Prediction produced high correlation coefficients between laboratory and predicted values for holocellulose and alpha-cellulose contents, which R2 values are 0.7467 and 0.8505, and RMSEP are 0.993 and 0.553, respectively. This study showed that NIR analysis can be reliably used to predict holocellulose and alpha-cellulose contents in triploid clones of Populus tomentosa.


2008 ◽  
Vol 52 (No. 9) ◽  
pp. 284-291 ◽  
Author(s):  
K. Šustová ◽  
J. Růžičková ◽  
J. Kuchtík

Our study deals with a possibility of determining true protein and casein in cow’s, ewe’s and goat’s milk and in ewe’s colostrums by FT NIR spectroscopy. Samples of milk were analysed by FT NIR in the reflectance mode with the transflectance cuvette. The values of correlation coefficients of calibration were as follows: cow’s protein 0.943; cow’s casein 0.964; ewe’s protein 0.997; ewe’s casein 0.977; goat’s protein 0.989; goat’s casein 0.890; ewe’s colostrum protein 0.983. Calibration was tested using the same set of samples by the cross validation method. The values of correlation coefficients of validation were as follows: cow’s protein 0.923; cow’s casein 0.910; ewe’s protein 0.994; ewe’s casein 0.963; goat’s protein 0.972; goat’s casein 0.814; ewe’s colostrum protein 0.871. The NIRS results were compared with reference data and no significant differences between them were found (<i>P</i> = 0.05). Results of this study indicate that FT NIR spectroscopy can be used for a rapid analysis of protein and casein in cow’s, ewe’s and goat’s milk and ewe’s colostrum.


2011 ◽  
Vol 49 (No. 11) ◽  
pp. 500-510 ◽  
Author(s):  
M. Prevolnik ◽  
M. Čandek-Potokar ◽  
D. Škorjanc

In contrast to conventional methods for the determination of meat chemical composition and quality, near infrared spectroscopy (NIRS) enables rapid, simple and simultaneous assessment of numerous meat properties. The present article is a review of published studies that examined the ability of NIRS to predict different meat properties. According to the published results, NIRS shows a great potential to replace the expensive and time-consuming chemical analysis of meat composition. On the other hand, NIRS is less accurate for predicting different attributes of meat quality. In view of meat quality evaluation, the use of NIRS appears more promising when categorizing meat into quality classes on the basis of meat quality traits for example discriminating between feeding regimes, discriminating fresh from frozen-thawed meat, discriminating strains, etc. The performance of NIRS to predict meat properties seems limited by the reliability of the method to which it is calibrated. Moreover, the use of NIRS may also be limited by the fact that it needs a laborious calibration for every purpose. In spite of that, NIRS is considered to be a very promising method for rapid meat evaluation. &nbsp; &nbsp;


Author(s):  
Karla Beltrame ◽  
Thays Gonçalves ◽  
Paulo Março ◽  
Sandra Gomes ◽  
Makoto Matsushita ◽  
...  

This work shows an alternative methodology based on a portable near-infrared (NIR) spectroscopy coupled to independent components analysis (ICA) in a pseudo-univariate calibration way to determine total anthocyanins (TA) concentration and antioxidant activity (AA) in whole grape juice. To this, the scores proportions more related to TA and AA were plotted against TA and AA obtained by its respective references methodology to build pseudo-univariate calibration models with correlation coefficients of 0.9699 and 0.9814, respectively. From the results, it is possible the suggestion that NIR spectra coupled to ICA enable to overcome interferences using first-order data and work properly when there is enough selectivity for the analyte profile in the sample data.


2006 ◽  
Vol 75 (1) ◽  
pp. 57-63 ◽  
Author(s):  
P. Navrátilová ◽  
L. Hadra ◽  
M. Dračková ◽  
B. Janštová ◽  
L. Vorlová ◽  
...  

Fourier transformation near infrared spectroscopy (FT-NIR) in combination with partial least squares (PLS) method were used to determine the content of total solids, fat, non-fatty solids, lactose and proteins in bovine colostrum. Spectra of 90 samples were measured in the reflectance mode with a transflectance cuvette in the 10000-4000 cm-1 spectral ranges with 100 scans. Calibration was performed and statistical values of correlation coefficients (R) and standard error of calibration values (SEC) were computed for total solids (0.986 and 0.919, respectively), fat (0.997 and 0.285, respectively), non-fatty solids (0.995 and 0.451, respectively), lactose (0.934 and 0.285, respectively) and protein (0.999 and 0.149, respectively). The calibration models developed were verified by cross validation. It follows from the study that FT-NIR spectroscopy can be used to determine the components of bovine colostrum.


2000 ◽  
Vol 8 (4) ◽  
pp. 251-257 ◽  
Author(s):  
Jolana Tarkošová ◽  
Jana Čopíková

Fourier transform near infrared (FT-NIR) spectroscopy was used to establish calibration equations with the aim of determining sucrose, lactose, fat and moisture in chocolate. The possibility of using FT-NIR spectroscopy for evaluating rheological properties (viscosity and yield) of chocolate was also investigated. The concentrations of individual components and the values of viscosity and yield obtained by standard methods were used as reference values. The spectra of 96 chocolate samples were recorded in reflectance mode in the range of 910–2500 nm using an FT-NIR Nicolet Avatar 360N spectrometer equipped with the UpDRIFT accessory. The first or second derivative transformation of the original NIR spectra gave the best accuracy. A partial least squares (PLS) algorithm was used to create calibration models relating reference values to spectral data. The models were validated using cross-validation. The validation results proved that fat, sucrose and lactose can be predicted with sufficient accuracy, while predicted values for moisture, viscosity and yield are less reliable.


2018 ◽  
Vol 188 ◽  
pp. 04019 ◽  
Author(s):  
Antonios D. Tsolakis ◽  
Konstantinos I. Giannakopoulos ◽  
Andreas S. Gkertsos

Gears are the main machine element in vehicle power transmission trains. In commercial vehicles, power transmission trains design complexity consists of the determination of the loading parameters which depends upon the working environment of the performance vehicle. In the present work a gear failure under dynamic loading is investigated. The failed gear is part of a 2 speed gearbox of a Rotax DD2 2-stroke Open- Wheel performance vehicle (go-cart type). The gearbox was in racing conditions when failure occurred. The vehicle was speeding in 2nd Gear at wide open throttle when instantaneously the driver by fault downshifted to 1st gear. The result was for the first gears break a whole piece and eventually the system to go out of operation. Chemical composition of the examined metallic components was determined via EDAX chemical analysis.


2013 ◽  
Vol 365-366 ◽  
pp. 737-740
Author(s):  
Li Jun Yao ◽  
Jie Mei Chen ◽  
Tao Pan

Near-infrared (NIR) spectroscopy combined with moving window partial least squares (MWPLS) method was successfully applied to the waveband selection for the rapid chemical-free determination of Zn2+ in soil. Based on randomness and similarity, an effective approach was performed to obtain objective and practical models. The optimal MWPLS waveband was 1136-1252 nm, and the corresponding optimal number of PLS factors was 6. The validation root mean square error (V-SEP) and validation correlation coefficients (V-RP) of prediction were 15.658 mg kg-1 and 0.925, respectively. The Zn2+ prediction values of the validation samples are close to the measured values. The results provided a reliable NIR model and can serve as valuable references for designing the dedicated spectroscopic instruments.


1998 ◽  
Vol 52 (1) ◽  
pp. 7-16 ◽  
Author(s):  
H. Swierenga ◽  
W. G. Haanstra ◽  
A. P. De Weijer ◽  
L. M. C. Buydens

Recently, efficient methods have become available to transfer a multivariate calibration model from one instrument to another. Two categories can be distinguished: improvement of the robustness of the calibration model by, for example, a proper data preprocessing; and adaptation of the calibration model by, for example, (piecewise) direct standardization. In direct standardization, a subset from the calibration set should be measured on both instruments. Usually, however, the calibration samples cannot be measured on both instruments. When data preprocessing is applied to the transfer of multivariate calibration models, there is no need for remeasurement of a subset on both instruments. In this paper, both categories are compared for the determination of the component concentrations in a ternary mixture of methanol, ethanol, and 1-propanol using NIR spectroscopy. The calibration models obtained on one instrument are transferred to other NIR instruments. It has been found that the results of proper data preprocessing are comparable with the results obtained by direct standardization when the models are transferred over three NIR instruments.


Sign in / Sign up

Export Citation Format

Share Document