scholarly journals Nutritional assessment with bioelectrical impedance analysis in maintenance hemodialysis patients.

1995 ◽  
Vol 6 (1) ◽  
pp. 75-81
Author(s):  
G M Chertow ◽  
E G Lowrie ◽  
D W Wilmore ◽  
J Gonzalez ◽  
N L Lew ◽  
...  

Protein energy malnutrition is common among persons with ESRD and contributes substantially to morbidity and mortality. The usual methods of nutritional assessment, such as anthropometry, can be misleading because of altered tissue hydration. Bioelectrical impedance analysis (BIA) has been recommended by some as a practical nutritional assessment tool but has not been validated in patients with ESRD. Thirty-three stable patients on maintenance hemodialysis were evaluated in an ambulatory clinical research center with simultaneous BIA, dual-energy x-ray absorptiometry, and deuterium oxide (D2O) and sodium bromide (NaBr) isotope dilution studies. Standard determinations of total body water (TBW) and body cell mass (BCM) were obtained and compared with values estimated by BIA. Two separate outpatient BIA measurements were also obtained approximately 2 wk before and after the clinical research center evaluation. BCM estimated by BIA was directly correlated (r = 0.92, P < 0.0001) with BCM determined by DEXA and NaBr. TBW estimated by BIA was directly correlated (r = 0.96, P < 0.0001) with TBW determined by deuterium oxide dilution. The reactance to resistance ratio (Xc/R) derived from BIA was inversely correlated (r = -0.73, P < 0.0001) with the extracellular water/TBW ratio determined by NaBr/D2O. Bland-Altman analyses showed that for TBW, BIA was in excellent agreement with D2O dilution. BCM was modestly underestimated by BIA compared with the dual-energy x-ray absorptiometry/NaBr standard and was adjusted by linear regression. The coefficients of variation on repeated BIA measurements were below 4%, demonstrating test-retest reliability. BIA is a valid and reliable method of nutritional assessment in maintenance hemodialysis patients.

2018 ◽  
Vol 2018 ◽  
pp. 1-11 ◽  
Author(s):  
Kulapong Jayanama ◽  
Supanee Putadechakun ◽  
Praopilad Srisuwarn ◽  
Sakda Arj-Ong Vallibhakara ◽  
Prapimporn Chattranukulchai Shantavasinkul ◽  
...  

Background. Body composition measurement is very important for early nutritional care in hemodialysis patients. Dual-energy X-ray absorptiometry (DXA) is a gold standard test, but clinically limited. Bioelectrical impedance analysis (BIA) with multifrequency technique is a practical and reliable tool. Objective. This cross-sectional study was aimed to compare the agreement of BIA with DXA in measurement of body composition in hemodialysis patients and to evaluate their associated factors. Methods. Body composition was measured by 2 BIA methods (InBody S10 and InBody 720) and DXA after a hemodialysis session. A total of 69 measurements were included. Pearson’s correlation and Bland and Altman analysis were used to determine the correlation of body composition between methods and to compare the methods agreement, respectively. Results. The correlation coefficients of body compositions were strong between DXA and InBody S10 (fat mass index (FMI): r=0.95, fat-free mass index (FFMI): r=0.78) and also between DXA and InBody 720 (FMI: r=0.96, FFMI: r=0.81). Comparing to DXA, the means of each body composition measured by InBody S10 method were not significantly different in each gender, but differences were found in FM, %FM, and FMI measured by InBody 720. Conclusions. In maintenance hemodialysis patients, the measurement of body composition with DXA and both BIA methods had highly significant correlations; practically, BIA method could be used as an instrument to follow FM and FFM and to measure the edematous stage. Further studies with large populations are warranted.


Sign in / Sign up

Export Citation Format

Share Document