Effect of chloride-induced reinforcing steel corrosion on the flexural strength of reinforced concrete beams

2012 ◽  
Vol 64 (6) ◽  
pp. 471-485 ◽  
Author(s):  
Jin Xia ◽  
Wei-Liang Jin ◽  
Long-Yuan Li
Materials ◽  
2020 ◽  
Vol 13 (1) ◽  
pp. 234 ◽  
Author(s):  
Yingwu Zhou ◽  
Yaowei Zheng ◽  
Lili Sui ◽  
Biao Hu ◽  
Xiaoxu Huang

Steel corrosion is considered as the main factor for the insufficient durability of concrete structures, especially in the marine environment. In this paper, to further inhibit steel corrosion in a high chloride environment and take advantage of the dual-functional carbon fiber reinforced polymer (CFRP), the impressed current cathodic protection (ICCP) technique was applied to the hybrid-reinforced concrete beam with internally embedded CFRP bars and steel fiber reinforced polymer composite bar (SFCB) as the anode material while the steel bar was compelled to the cathode. The effect of the new ICCP system on the flexural performance of the hybrid-reinforced concrete beam subjected to corrosion was verified experimentally. First, the electricity-accelerated precorrosion test was performed for the steel bar in the hybrid-reinforced beams with a target corrosion ratio of 5%. Then, the dry–wet cycles corrosion was conducted and the ICCP system was activated simultaneously for the hybrid-reinforced concrete beam for 180 days. Finally, the three-point bending experiment was carried out for the hybrid-reinforced concrete beams. The steel bars were taken out from the concrete to quantitatively measure the corrosion ratio after flexural tests. Results showed that the further corrosion of steel bars could be inhibited effectively by the ICCP treatment with the CFRP bar and the SFCB as the anode. Additionally, the ICCP system showed an obvious effect on the flexural behavior of the hybrid-reinforced concrete beams: The crack load and ultimate load, as well as the stiffness, were enhanced notably compared with the beam without ICCP treatment. Compared with the SFCB anode, the ICCP system with the CFRP bar as the anode material was more effective for the hybrid-reinforced concrete beam to prevent the steel corrosion.


2017 ◽  
Vol 64 (1) ◽  
pp. 69-74 ◽  
Author(s):  
Shamsad Ahmad

Purpose This study aims to make an effort to develop a model to predict the residual flexural strength of reinforced concrete beams subjected to reinforcement corrosion. Design/methodology/approach For generating the required data to develop the model, a set of experimental variables was considered that included corrosion current density, corrosion duration, rebar diameter and thickness of concrete cover. A total of 28 sets of reinforced concrete beams of size 150 × 150 × 1,100 mm were cast, of which 4 sets of un-corroded beams were tested in four-point bend test as control beams and the remaining 24 sets of beams were subjected to accelerated rebar corrosion inducing different levels of corrosion current densities for different durations. Corroded beams were also tested in flexure, and test results of un-corroded and corroded beams were utilized to obtain an empirical model for estimating the residual flexural strength of beams for given corrosion current density, corrosion duration and diameter of the rebars. Findings Comparison of the residual flexural strengths measured experimentally for a set of corroded beams, reported in literature, with that predicted using the model proposed in this study indicates that the proposed model has a reasonably good accuracy. Originality/value The empirical model obtained under this work can be used as a simple tool to predict residual flexural strength of corroded beams using the input data that include rebar corrosion rate, corrosion duration after initiation and diameter of rebars.


2010 ◽  
Vol 62 (6) ◽  
pp. 405-414 ◽  
Author(s):  
A.K. Azad ◽  
S. Ahmad ◽  
B.H.A. Al-Gohi

2013 ◽  
Vol 680 ◽  
pp. 230-233 ◽  
Author(s):  
Yong Taeg Lee ◽  
Seung Hun Kim ◽  
Jong Hyeon Kim ◽  
Sang Ki Baek ◽  
Young Sang Cho ◽  
...  

Recently, many structures which were built about 30 years ago are watched by reconstruction. Demolished concrete is occurred in the process and these quantity increase about 10% more than the preceding year. Fortunately, recycled aggregates are produced from demolished concrete, whereas the recycled aggregates are not used often because there are not many researches which have been verified by experts or researchers about strength when reinforced concrete is made with recycled aggregates. In this paper, high strength reinforced concrete is valued with potential applications and check change of strength when it made by recycled aggregates. For this, flexural tests of 4 high strength reinforced concrete beams with recycled aggregates were performed, and the high strength reinforced concrete beams were tested within the limits such as compressive strength, flexural strength, ductility, strain, and curvature. The current test data were examined in terms of flexural strength, along with the data from previously tested reinforced concrete beams with recycled aggregates.