Potential use of small-diameter concrete cores for in situ compressive strength assessment

2019 ◽  
Vol 71 (15) ◽  
pp. 809-826
Author(s):  
Mayssaa El-Moussaoui ◽  
Ravindra K. Dhir ◽  
Peter Robery

There is a necessity for a modern method to evaluate the insitu strength of concrete thereby increasing the rate of productivity in concrete industry. This method can address immediate challenges faced such as predicting right time for formwork removal, post-tensioning, at low temperatures while the strength gain of concrete is hindered, optimizing concrete mix design and cold weather protection. The temperature is measured using wireless sensor that offers a simple solution to concrete maturity monitoring. The temperature and humidity on various days is observed. The compressive strength at 1,3,7,14 and 28 day is observed. This paper includes calculation of maturity index using Nurse-Saul equation. A graph is plot between maturity index and compressive strength. The best fit strength-maturity equation is chosen based upon the obtained curve and thereby the in-situ strength of concrete is evaluated.


2013 ◽  
Vol 778 ◽  
pp. 209-216 ◽  
Author(s):  
Miloš Drdácký ◽  
Michal Kloiber

The paper presents a novel concept and a prototype of a diagnostic tool for in-situ assessment of timber in existing structures and buildings. The device enables direct determination of conventional compressive strength and modulus of deformation in arbitrary depth along timber profile. The measurement of the stress-deformation relationship is performed in a prepared hole of a very small diameter by means of a special small size symmetrical loading jack. Testing and verification of the new device behaviour during loading of wood along the fibres has been carried out on fir which is the most frequent wood species in European buildings. The comparison of stress-strain diagrams acquired by means of the new device with those measured in compliance with the European standard for testing of wood shows a very good correlation including the determination of the compressive strength values. This semi-destructive method causes a very gentle damage and can be also used for the assessment of historic timber structures.


Author(s):  
Z. Liliental-Weber ◽  
C. Nelson ◽  
R. Ludeke ◽  
R. Gronsky ◽  
J. Washburn

The properties of metal/semiconductor interfaces have received considerable attention over the past few years, and the Al/GaAs system is of special interest because of its potential use in high-speed logic integrated optics, and microwave applications. For such materials a detailed knowledge of the geometric and electronic structure of the interface is fundamental to an understanding of the electrical properties of the contact. It is well known that the properties of Schottky contacts are established within a few atomic layers of the deposited metal. Therefore surface contamination can play a significant role. A method for fabricating contamination-free interfaces is absolutely necessary for reproducible properties, and molecularbeam epitaxy (MBE) offers such advantages for in-situ metal deposition under UHV conditions


2013 ◽  
Vol 12 (3) ◽  
Author(s):  
Sudarmadi Sudarmadi

In this paper a case study about concrete strength assessment of bridge structure experiencing fire is discussed. Assessment methods include activities of visual inspection, concrete testing by Hammer Test, Ultrasonic Pulse Velocity Test, and Core Test. Then, test results are compared with the requirement of RSNI T-12-2004. Test results show that surface concrete at the location of fire deteriorates so that its quality is decreased into the category of Very Poor with ultrasonic pulse velocity ranges between 1,14 – 1,74 km/s. From test results also it can be known that concrete compressive strength of inner part of bridge pier ranges about 267 – 274 kg/cm2 and concrete compressive strength of beam and plate experiencing fire directly is about 173 kg/cm2 and 159 kg/cm2. It can be concluded that surface concrete strength at the location of fire does not meet the requirement of RSNI T-12-2004. So, repair on surface concrete of pier, beam, and plate at the location of fire is required.


Water ◽  
2021 ◽  
Vol 13 (10) ◽  
pp. 1409
Author(s):  
Hamdhani Hamdhani ◽  
Drew E. Eppehimer ◽  
David Walker ◽  
Michael T. Bogan

Chlorophyll-a measurements are an important factor in the water quality monitoring of surface waters, especially for determining the trophic status and ecosystem management. However, a collection of field samples for extractive analysis in a laboratory may not fully represent the field conditions. Handheld fluorometers that can measure chlorophyll-a in situ are available, but their performance in waters with a variety of potential light-interfering substances has not yet been tested. We tested a handheld fluorometer for sensitivity to ambient light and turbidity and compared these findings with EPA Method 445.0 using water samples obtained from two urban lakes in Tucson, Arizona, USA. Our results suggested that the probe was not sensitive to ambient light and performed well at low chlorophyll-a concentrations (<25 µg/L) across a range of turbidity levels (50–70 NTU). However, the performance was lower when the chlorophyll-a concentrations were >25 µg/L and turbidity levels were <50 NTU. To account for this discrepancy, we developed a calibration equation to use for this handheld fluorometer when field monitoring for potential harmful algal blooms in water bodies.


2020 ◽  
Vol 1 ◽  
Author(s):  
Mohammed A. Hefni

Abstract The use of natural pozzolans in concrete applications is gaining more attention because of the associated environmental, economic, and technical benefits. In this study, reference cemented mine backfill samples were prepared using Portland cement, and experimental samples were prepared by partially replacing Portland cement with 10 or 20 wt.% fly ash as a byproduct (artificial) pozzolan or pumice as a natural pozzolan. Samples were cured for 7, 14, and 28 days to investigate uniaxial compressive strength development. Backfill samples containing 10 wt.% pumice had almost a similar compressive strength as reference samples. There is strong potential for pumice to be used in cemented backfill to minimize costs, improve backfill properties, and promote the sustainability of the mining industry.


2021 ◽  
Vol 13 (9) ◽  
pp. 1846
Author(s):  
Vivek Kumar ◽  
Isabel M. Morris ◽  
Santiago A. Lopez ◽  
Branko Glisic

Estimating variations in material properties over space and time is essential for the purposes of structural health monitoring (SHM), mandated inspection, and insurance of civil infrastructure. Properties such as compressive strength evolve over time and are reflective of the overall condition of the aging infrastructure. Concrete structures pose an additional challenge due to the inherent spatial variability of material properties over large length scales. In recent years, nondestructive approaches such as rebound hammer and ultrasonic velocity have been used to determine the in situ material properties of concrete with a focus on the compressive strength. However, these methods require personnel expertise, careful data collection, and high investment. This paper presents a novel approach using ground penetrating radar (GPR) to estimate the variability of in situ material properties over time and space for assessment of concrete bridges. The results show that attributes (or features) of the GPR data such as raw average amplitudes can be used to identify differences in compressive strength across the deck of a concrete bridge. Attributes such as instantaneous amplitudes and intensity of reflected waves are useful in predicting the material properties such as compressive strength, porosity, and density. For compressive strength, one alternative approach of the Maturity Index (MI) was used to estimate the present values and compare with GPR estimated values. The results show that GPR attributes could be successfully used for identifying spatial and temporal variation of concrete properties. Finally, discussions are presented regarding their suitability and limitations for field applications.


2006 ◽  
Vol 309-311 ◽  
pp. 857-860 ◽  
Author(s):  
Q. Yao ◽  
Dong Xiao Li ◽  
K.W. Liu ◽  
Bo Zhang ◽  
H. Li ◽  
...  

This study was to develop an injectable biocompatible and porous calcium phosphate collagen composite cement scaffold by in situ setting. TTCP was prepared as main material of the CPC powder, and the collagen solution was added into the phosphoric acid directly to form the liquid phase. The injectable time (tI), setting time (tS) and setting temperature (TS), along with the PH value were recorded during the setting process. The compressive strength, morphology and porosity were tested. With the increase of collagen, this novel CPC get a tI of 5mins to 8mins, tS of 20mins to 30mins, compressive strength from 1.5MPa to 4MPa, and the porosity from 40% to 60%. This study gave a possibility to form a porous scaffold of collagen/CPC composite with the nature of injectability and setting in situ.


Sign in / Sign up

Export Citation Format

Share Document