Chemical Dosimetry in the “Water Window”: Ferric Ions and Hydroxyl Radicals Produced by Intense Soft X Rays

2020 ◽  
Vol 193 (4) ◽  
pp. 372
Author(s):  
Luděk Vyšín ◽  
Przemysław Wachulak ◽  
Martina Toufarová ◽  
Nikita Medvedev ◽  
Roman A. Voronkov ◽  
...  
Author(s):  
Steve Lindaas ◽  
Chris Jacobsen ◽  
Alex Kalinovsky ◽  
Malcolm Howells

Soft x-ray microscopy offers an approach to transmission imaging of wet, micron-thick biological objects at a resolution superior to that of optical microscopes and with less specimen preparation/manipulation than electron microscopes. Gabor holography has unique characteristics which make it particularly well suited for certain investigations: it requires no prefocussing, it is compatible with flash x-ray sources, and it is able to use the whole footprint of multimode sources. Our method serves to refine this technique in anticipation of the development of suitable flash sources (such as x-ray lasers) and to develop cryo capabilities with which to reduce specimen damage. Our primary emphasis has been on biological imaging so we use x-rays in the water window (between the Oxygen-K and Carbon-K absorption edges) with which we record holograms in vacuum or in air.The hologram is recorded on a high resolution recording medium; our work employs the photoresist poly(methylmethacrylate) (PMMA). Following resist “development” (solvent etching), a surface relief pattern is produced which an atomic force microscope is aptly suited to image.


2019 ◽  
Vol 10 (1) ◽  
Author(s):  
Alexandra Guerreiro ◽  
Nicholas Chatterton ◽  
Eleanor M. Crabb ◽  
Jon P. Golding

Abstract Background A wide range of nanoparticles (NPs), composed of different elements and their compounds, are being developed by several groups as possible radiosensitisers, with some already in clinical trials. However, no systematic experimental survey of the clinical X-ray radiosensitising potential of different element nanoparticles has been made. Here, we directly compare the irradiation-induced (10 Gy of 6-MV X-ray photon) production of hydroxyl radicals, superoxide anion radicals and singlet oxygen in aqueous solutions of the following metal oxide nanoparticles: Al2O3, SiO2, Sc2O3, TiO2, V2O5, Cr2O3, MnO2, Fe3O4, CoO, NiO, CuO, ZnO, ZrO2, MoO3, Nd2O3, Sm2O3, Eu2O3, Gd2O3, Tb4O7, Dy2O3, Er2O3 and HfO2. We also examine DNA damage due to these NPs in unirradiated and irradiated conditions. Results Without any X-rays, several NPs produced more radicals than water alone. Thus, V2O5 NPs produced around 5-times more hydroxyl radicals and superoxide radicals. MnO2 NPs produced around 10-times more superoxide anions and Tb4O7 produced around 3-times more singlet oxygen. Lanthanides produce fewer hydroxyl radicals than water. Following irradiation, V2O5 NPs produced nearly 10-times more hydroxyl radicals than water. Changes in radical concentrations were determined by subtracting unirradiated values from irradiated values. These were then compared with irradiation-induced changes in water only. Irradiation-specific increases in hydroxyl radical were seen with most NPs, but these were only significantly above the values of water for V2O5, while the Lanthanides showed irradiation-specific decreases in hydroxyl radical, compared to water. Only TiO2 showed a trend of irradiation-specific increase in superoxides, while V2O5, MnO2, CoO, CuO, MoO3 and Tb4O7 all demonstrated significant irradiation-specific decreases in superoxide, compared to water. No irradiation-specific increases in singlet oxygen were seen, but V2O5, NiO, CuO, MoO3 and the lanthanides demonstrated irradiation-specific decreases in singlet oxygen, compared to water. MoO3 and CuO produced DNA damage in the absence of radiation, while the highest irradiation-specific DNA damage was observed with CuO. In contrast, MnO2, Fe3O4 and CoO were slightly protective against irradiation-induced DNA damage. Conclusions Beyond identifying promising metal oxide NP radiosensitisers and radioprotectors, our broad comparisons reveal unexpected differences that suggest the surface chemistry of NP radiosensitisers is an important criterion for their success.


2015 ◽  
Vol 22 (3) ◽  
pp. 819-827 ◽  
Author(s):  
Max Rose ◽  
Petr Skopintsev ◽  
Dmitry Dzhigaev ◽  
Oleg Gorobtsov ◽  
Tobias Senkbeil ◽  
...  

A ptychographical coherent diffractive imaging experiment in the water window with focused soft X-rays at 500 eV is reported. An X-ray beam with high degree of coherence was selected for ptychography at the P04 beamline of PETRA III synchrotron radiation source. The beam coherence was measured with the newly developed non-redundant array method, and a coherence length of 4.1 µm and global degree of coherence of 35% at 100 µm exit slit opening in the vertical direction were determined. A pinhole, 2.6 µm in size, selected the coherent part of the beam that was used to obtain ptychographic reconstruction results of a lithographically manufactured test sample and a fossil diatom. The achieved resolution was 53 nm for the test sample and was only limited by the size of the detector. The diatom was imaged at a resolution better than 90 nm.


2018 ◽  
Vol 51 (17) ◽  
pp. 174004 ◽  
Author(s):  
V Cardin ◽  
B E Schimdt ◽  
N Thiré ◽  
S Beaulieu ◽  
V Wanie ◽  
...  

Science ◽  
1997 ◽  
Vol 278 (5338) ◽  
pp. 549m-549
Keyword(s):  
X Rays ◽  

2020 ◽  
Vol 27 (6) ◽  
pp. 1614-1617
Author(s):  
Jingtao Zhu ◽  
Jiayi Zhang ◽  
Haochuan Li ◽  
Yuchun Tu ◽  
Jinwen Chen ◽  
...  

The `water window', covering 2.4–4.4 nm, is an important wavelength range particularly essential to biology research. Cr/Ti multilayers are one of the promising reflecting elements in this region because the near-normal-incidence reflectivity is theoretically as high as 64% at 2.73 nm. However, due to multilayer imperfections, the reported reflectivity is lower than 3% for near-normal incidence. Here, B and C were intentionally incorporated into ultra-thin Cr/Ti soft X-ray multilayers by co-deposition of B4C at the interfaces. The effect on the multilayer structure and composition has been investigated using X-ray reflectometry, X-ray photoelectron spectroscopy, and cross-section electron microscopy. It is shown that B and C are mainly bonded to Ti sites, forming a nonstoichiometric TiB x C y composition, which hinders the interface diffusion, supresses the crystallization of the Cr/Ti multilayer and dramatically improves the interface quality of Cr/TiB x C y multilayers. As a result, the near-normal-incidence reflectivity of soft X-rays increases from 4.48% to 15.75% at a wavelength of 2.73 nm.


Author(s):  
Seunghwoi Han ◽  
Jie Li ◽  
Zheyuan Zhu ◽  
Andrew Chew ◽  
Esben W. Larsen ◽  
...  
Keyword(s):  
X Rays ◽  

2014 ◽  
Vol 228 (10-12) ◽  
Author(s):  
Thomas Gorniak ◽  
Axel Rosenhahn

AbstractImaging is one of the key drivers for new scientific insights – from the observation of distant stars in astronomy to microscopic studies of sub-cellular structures in biology. In the latter case, X-rays are a versatile probe due to their small wavelength and thus high spatial sensitivity. We give an overview of applicable lensless, coherent imaging approaches relying on scattering with a focus on ptychographic microscopy and discuss the experimental requirements for the soft X-ray scattering experiment HORST. Besides the experiment itself, we highlight the importance of sample environments, especially when biological specimens are investigated. Here, the water window is of central importance. In addition to exploitation of the contrast and resolution, resonant ptychography allows to distinguish chemical species at high spatial resolution with both phase and amplitude contrast.


Sign in / Sign up

Export Citation Format

Share Document