Development and validation of a stability-indicating RP-LC method for the determination of rosuvastatin calcium and ezetimibe in the presence of their acid degradation products in bulk drug, mixture and pharmaceutical preparations with kinetic study of rosuvastatin and ezetimibe acid degradation

2014 ◽  
Vol 1 (1) ◽  
pp. 1-16
Author(s):  
Ahmed Kadry ◽  
◽  
Ramzia El-Bagary ◽  
Ehab Elkady ◽  
Zeinab El-Sherif
Author(s):  
Mrinalini C. Damle ◽  
Swapnil S Waghmare ◽  
PURUSHOTAM SINHA

Objective: To develop and validate simple, sensitive stability indicating HPTLC (High performance thin layer chromatography) method for apixaban. Methods: The chromatographic separation was performed on aluminium plates precoated with silica gel 60 F254 using toluene: ethyl acetate: methanol (3:6:1 v/v/v) as mobile phase followed by densitometric scanning at 279 nm. Results: The chromatographic condition shows sharp peak of apixaban at Rf value of 0.38±0.03. Stress testing was carried out according to international conference on harmonization (ICH)Q1A (R2) guidelines and the method was validated as per ICH Q2(R1) guidelines. The calibration curve was found to be linear in the concentration range of 100-500 ng/band for apixaban. The limit of detection and quantification was found to be 11.66ng/bandand35.33ng/band, respectively. Conclusion: A new simple, sensitive, stability indicating high performance thin layer chromatographic (HPTLC) method has been developed and validated for the determination of apixaban.


2017 ◽  
Vol 9 (6) ◽  
pp. 80
Author(s):  
H. Padh ◽  
S. Parmar ◽  
B. Patel

Objective: In the present study a novel stability-indicating high-performance thin-layer chromatography (HPTLC) method for quantitative determination of Swertiamarin (SW) in bulk drug and formulation has been developed and validated as per ICH guideline Q2 (R1) for global acceptance of standardized herbal formulations.Methods: HPTLC method is developed and validated using solvent ethyl acetate: ethanol: chloroform (3:2.5:4.5 v/v/v) (Rf of SW 0.65±0.04) in the absorbance mode at 243 nm. Various forced degradation conditions were used to check degradation of drug.Results: The method showed a good linear relationship (r2 = 0.9990) in the concentration range 200-700 ng per spot. It was found to be linear, accurate, precise and specific.Conclusion: It can be applied for quality control as well as for stability testing of different dosage forms containing swertiamarin. The developed method is validated as per ICH guideline Q2(R1) for global acceptance of standardized herbal formulations.


2013 ◽  
Vol 96 (3) ◽  
pp. 580-586 ◽  
Author(s):  
Yousry M Issa ◽  
Emad M Hussien ◽  
Magda M Ibrahim ◽  
Fatma M Abdel-Gawad ◽  
Saadia Barakat

Abstract Two stability-indicating methods were developed for the determination of candesartan cilexetil in the presence of its degradation products. The first method uses isocratic RP-HPLC with an Agilent C18 column. The mobile phase was phosphate buffer (pH = 2.8 ± 0.1)–acetonitrile (60 + 40, v/v). The flow rate was 2.0 mL/min, and the UV detection was at 254 nm. The second method depends on TLC-densitometric measurements of drug spots at 254 nm. The separation was carried out on silica gel 60 F254 plates using ethyl acetate–methanol–toluene– ammonia 33% (40 + 25 + 20 + 2, v/v/v/v) mobile phase. The methods were validated according to U.S. Pharmacopeia guidelines, and the acceptance criteria for accuracy, precision, linearity, specificity, robustness, LOD, LOQ, and system suitability were met in all cases. Linear ranges of the methods were 10.0–200.0 μg/mL and 1.0–9.0 μg/spot for HPLC and TLC, respectively. The proposed methods were successfully applied to the drug in bulk powder, in laboratory-prepared mixtures with its degradation products, and in commercially available tablets. The results were compared statistically at the 95% confidence level with each other. There were no significant differences between the mean recovery and precision of the two methods.


Sign in / Sign up

Export Citation Format

Share Document