A New High Performance CA Resist for E-beam Lithography

1999 ◽  
Vol 584 ◽  
Author(s):  
Ranee Kwong ◽  
Wu-Song Huang ◽  
Wayne Moreau ◽  
Robert Lang ◽  
Christopher Robinson ◽  
...  

AbstractThree major lithographic applications have emerged for electron beam exposure tools: optical mask fabrication, direct writing for device fabrication, and more recently projection e-beam printing. The traditional mask making process uses poly(butenesulfone) resist. A wet etch process was adopted to generate patterns on chrome. Recently, shrinking dimensions, optical proximity correction features, and the complexity of phase shift masks have forced the industry to a chrome dry etch process. ZEP, a poly(methyl α-chloroacrylate-co-α-methylstyrene) based resist, has been well accepted for most of the >180 nm device mask making. The acceptance of ZEP comes in spite of its low contrast, marginal etch resistance, organic solvent development, and concerns of resist heating associated with its high dose requirements. These issues have spawned interest in using chemically amplified resist (CAR) systems for direct write and mask making applications. We have developed a high contrast resist based on ketal protecting groups, KRS-XE, which is robust against airborne contamination and can be used for all forms of e-beam exposure in both chrome mask and silicon processing. This high contrast resist is processed with aqueous base developer and has a wide bake latitude. The development of KRS-XE has provided the capability of fabricating chrome masks for future generation (< 180 nm) devices and has potential for use with projection beam exposure systems.

Author(s):  
Russell L. Steere ◽  
Eric F. Erbe ◽  
J. Michael Moseley

We have designed and built an electronic device which compares the resistance of a defined area of vacuum evaporated material with a variable resistor. When the two resistances are matched, the device automatically disconnects the primary side of the substrate transformer and stops further evaporation.This approach to controlled evaporation in conjunction with the modified guns and evaporation source permits reliably reproducible multiple Pt shadow films from a single Pt wrapped carbon point source. The reproducibility from consecutive C point sources is also reliable. Furthermore, the device we have developed permits us to select a predetermined resistance so that low contrast high-resolution shadows, heavy high contrast shadows, or any grade in between can be selected at will. The reproducibility and quality of results are demonstrated in Figures 1-4 which represent evaporations at various settings of the variable resistor.


Author(s):  
N. Lewis ◽  
E. L. Hall ◽  
A. Mogro-Campero ◽  
R. P. Love

The formation of buried oxide structures in single crystal silicon by high-dose oxygen ion implantation has received considerable attention recently for applications in advanced electronic device fabrication. This process is performed in a vacuum, and under the proper implantation conditions results in a silicon-on-insulator (SOI) structure with a top single crystal silicon layer on an amorphous silicon dioxide layer. The top Si layer has the same orientation as the silicon substrate. The quality of the outermost portion of the Si top layer is important in device fabrication since it either can be used directly to build devices, or epitaxial Si may be grown on this layer. Therefore, careful characterization of the results of the ion implantation process is essential.


Author(s):  
S. Yegnasubramanian ◽  
V.C. Kannan ◽  
R. Dutto ◽  
P.J. Sakach

Recent developments in the fabrication of high performance GaAs devices impose crucial requirements of low resistance ohmic contacts with excellent contact properties such as, thermal stability, contact resistivity, contact depth, Schottky barrier height etc. The nature of the interface plays an important role in the stability of the contacts due to problems associated with interdiffusion and compound formation at the interface during device fabrication. Contacts of pure metal thin films on GaAs are not desirable due to the presence of the native oxide and surface defects at the interface. Nickel has been used as a contact metal on GaAs and has been found to be reactive at low temperatures. Formation Of Ni2 GaAs at 200 - 350C is reported and is found to grow epitaxially on (001) and on (111) GaAs, but is shown to be unstable at 450C. This paper reports the investigations carried out to understand the microstructure, nature of the interface and composition of sputter deposited and annealed (at different temperatures) Ni-Sb ohmic contacts on GaAs by TEM. Attempts were made to correlate the electrical properties of the films such as the sheet resistance and contact resistance, with the microstructure. The observations are corroborated by Scanning Auger Microprobe (SAM) investigations.


Author(s):  
María Carmen Sánchez-González ◽  
Raquel García-Oliver ◽  
José-María Sánchez-González ◽  
María-José Bautista-Llamas ◽  
José-Jesús Jiménez-Rejano ◽  
...  

In our work, we determined the value of visual acuity (VA) with ETDRS charts (Early Treatment Diabetic Retinopathy Study). The purpose of the study was to determine the measurement reliabilities, calculating the correlation coefficient interclass (ICC), the value of the error associated with the measure (SEM), and the minimal detectable change (MDC). Forty healthy subjects took part. The mean age was 23.5 ± 3.1 (19 to 26) years. Visual acuities were measured with ETDRS charts (96% ETDRS chart nº 2140) and (10% SLOAN Contrast Eye Test chart nº 2153). The measurements were made (at 4 m) under four conditions: Firstly, photopic conditions with high contrast (HC) and low contrast (LC) and after 15 min of visual rest, mesopic conditions with high and low contrast. Under photopic conditions and high contrast, the ICC = 0.866 and decreased to 0.580 when the luminosity and contrast decreased. The % MDC in the four conditions was always less than 10%. It was minor under photopic conditions and HC (5.83) and maximum in mesopic conditions and LC (9.70). Our results conclude a high reliability of the ETDRS test, which is higher in photopic and high contrast conditions and lower when the luminosity and contrast decreases.


2008 ◽  
Vol 20 (7) ◽  
pp. 1847-1872 ◽  
Author(s):  
Mark C. W. van Rossum ◽  
Matthijs A. A. van der Meer ◽  
Dengke Xiao ◽  
Mike W. Oram

Neurons in the visual cortex receive a large amount of input from recurrent connections, yet the functional role of these connections remains unclear. Here we explore networks with strong recurrence in a computational model and show that short-term depression of the synapses in the recurrent loops implements an adaptive filter. This allows the visual system to respond reliably to deteriorated stimuli yet quickly to high-quality stimuli. For low-contrast stimuli, the model predicts long response latencies, whereas latencies are short for high-contrast stimuli. This is consistent with physiological data showing that in higher visual areas, latencies can increase more than 100 ms at low contrast compared to high contrast. Moreover, when presented with briefly flashed stimuli, the model predicts stereotypical responses that outlast the stimulus, again consistent with physiological findings. The adaptive properties of the model suggest that the abundant recurrent connections found in visual cortex serve to adapt the network's time constant in accordance with the stimulus and normalizes neuronal signals such that processing is as fast as possible while maintaining reliability.


2011 ◽  
Vol 55 (12) ◽  
pp. 5480-5484 ◽  
Author(s):  
Yuhan Chang ◽  
Wen-Chien Chen ◽  
Pang-Hsin Hsieh ◽  
Dave W. Chen ◽  
Mel S. Lee ◽  
...  

ABSTRACTThe objective of this study was to evaluate the antibacterial effects of polymethylmethacrylate (PMMA) bone cements loaded with daptomycin, vancomycin, and teicoplanin against methicillin-susceptibleStaphylococcus aureus(MSSA), methicillin-resistantStaphylococcus aureus(MRSA), and vancomycin-intermediateStaphylococcus aureus(VISA) strains. Standardized cement specimens made from 40 g PMMA loaded with 1 g (low-dose), 4 g (middle-dose) or 8 g (high-dose) antibiotics were tested for elution characteristics and antibacterial activities. The patterns of release of antibiotics from the cement specimens were evaluated usingin vitrobroth elution assay with high-performance liquid chromatography. The activities of broth elution fluid against differentStaphylococcus aureusstrains (MSSA, MRSA, and VISA) were then determined. The antibacterial activities of all the tested antibiotics were maintained after being mixed with PMMA. The cements loaded with higher dosages of antibiotics showed longer elution periods. Regardless of the antibiotic loading dose, the teicoplanin-loaded cements showed better elution efficacy and provided longer inhibitory periods against MSSA, MRSA, and VISA than cements loaded with the same dose of vancomycin or daptomycin. Regarding the choice of antibiotics for cement loading in the treatment ofStaphylococcus aureusinfection, teicoplanin was superior in terms of antibacterial effects.


2017 ◽  
Vol 44 (9) ◽  
pp. e153-e163 ◽  
Author(s):  
Damien Racine ◽  
Anaïs Viry ◽  
Fabio Becce ◽  
Sabine Schmidt ◽  
Alexandre Ba ◽  
...  

2015 ◽  
Vol 24 (2) ◽  
pp. 97-102 ◽  
Author(s):  
Rita Lahirin ◽  
Inge Permadhi ◽  
Ninik Mudjihatini ◽  
Rahmawaty Ridwan ◽  
Ray Sugianto

Background: Green tea contains catechins that have inhibitory effects on amylase, sucrase, and sodium-dependent glucose transporter (SGLT) which result in lowering of postprandial blood glucose (PBG). This beneficial effect has been widely demonstrated using the usual dose (UD) of green tea preparation. Our study was aimed to explore futher lowering of PBG using high dose (HD) of green tea in healthy adolescents. Methods: 24 subjects received 100 mL infusion of either 0.67 or 3.33 grams of green tea with test meal. Fasting, PBG at 30, 60, 120 minutes were measured. Subjects were cross-overed after wash out. PBG and its incremental area under the curve (IAUC) difference between groups were analyzed with paired T-test. Cathecin contents of tea were measured using high-performance liquid chromatography (HPLC). Results: The PBG of HD group was lower compared to UD (at 60 minutes =113.70 ± 13.20 vs 124.16 ± 8.17 mg/dL, p = 0.005; at 120 minutes = 88.95 ± 6.13 vs 105.25 ± 13.85 mg/dL, p < 0.001). The IAUC of HD was also found to be lower compared to UD (2055.0 vs 3411.9 min.mg/dL, p < 0.001). Conclusion: Additional benefit of lowering PBG can be achieved by using higher dose of green tea. This study recommends preparing higher dose of green tea drinks for better control of PBG.


Materials ◽  
2021 ◽  
Vol 14 (16) ◽  
pp. 4634
Author(s):  
Kaixi Bi ◽  
Jiliang Mu ◽  
Wenping Geng ◽  
Linyu Mei ◽  
Siyuan Zhou ◽  
...  

Graphene nanostructures are widely perceived as a promising material for fundamental components; their high-performance electronic properties offer the potential for the construction of graphene nanoelectronics. Numerous researchers have paid attention to the fabrication of graphene nanostructures, based on both top-down and bottom-up approaches. However, there are still some unavoidable challenges, such as smooth edges, uniform films without folds, and accurate dimension and location control. In this work, a direct writing method was reported for the in-situ preparation of a high-resolution graphene nanostructure of controllable size (the minimum feature size is about 15 nm), which combines the advantages of e-beam lithography and copper-catalyzed growth. By using the Fourier infrared absorption test, we found that the hydrogen and oxygen elements were disappearing due to knock-on displacement and the radiolysis effect. The graphene crystal is also formed via diffusion and the local heating effect between the e-beam and copper substrate, based on the Raman spectra test. This simple process for the in-situ synthesis of graphene nanostructures has many promising potential applications, including offering a way to make nanoelectrodes, NEMS cantilever resonant structures, nanophotonic devices and so on.


Sign in / Sign up

Export Citation Format

Share Document