Fracture Toughness of Two Cr2Hf+Cr Intermetallic Composites as a Function Temperature
Keyword(s):
AbstractFracture toughness as a function of temperature was evaluated for two Cr2Hf+Cr intermetallic composites, each in two different microstructural conditions. The proeutectic microstructures based on Cr-6.5Hf (at%) showed a significant increase in fracture toughness with an increase from room temperature to 600°C. The coarse microstructure obtained by heat treatment at 1500°C showed evidence of ductile behavior of Cr at a lower test temperature (200°C) relative to that of one heat treated at 1250°C (400'C). In the eutectic microstructures based on Cr-13Hf, only a small increase in fracture toughness at 600°C was seen. The results are analyzed in the light of fracture micromechanisms.
Keyword(s):
1990 ◽
Vol 112
(1)
◽
pp. 116-123
◽
Keyword(s):
1973 ◽
Vol 46
(1)
◽
pp. 305-330
◽
Keyword(s):
Keyword(s):
Keyword(s):
2018 ◽
Vol 44
(6)
◽
pp. 11
◽
1983 ◽
Vol 41
◽
pp. 224-225