Materials Issues In X-Ray Mask Repair by Focused Ion Beams

1993 ◽  
Vol 306 ◽  
Author(s):  
John Melngailis

AbstractIn x-ray mask repair high Z absorber features, such as gold or tungsten, must be removed or added. The main challenges are the small lateral dimensions (0.25 μm and below) and the thickness of the absorbers (˜ 0.5 μm) The focused ion beam appears to be the best tool developed to meet this challenge. Unwanted features are removed by ion milling while missing absorber is reconstructed using ion induced deposition from a locally piped-in precursor gas. The high aspect ratio of the features complicates both of these processes. Milling away 0.5 μm thick absorber can lead to redeposition of the sputtered material on neighboring features. The crystal grains of the absorber mill at different rates depending on orientation which results in nonuniform features. A possible alternative which only works with W absorber is to use ion assisted etching. In ion induced deposition a precursor gas such as dimethylgold hexafluoro acetylacetonate is provided by a capillary tube aimed at the region scanned by the ion beam. The incident Ga+ ions, usually at energies in the 25–100 keV range, dissociate the adsorbed precursor molecules leaving a deposit of gold mixed with carbon. The carbon content can approach 50 atomic % resulting in an x-ray attenuation which is about one half of that of pure gold. A number of unexplored materials science issues are associated with mask repair including: the reduction of the carbon content, redeposition both from milling and from induced deposition, milling as a function of crystal orientation and energy, and deposition of high aspect features. The technology is well enough developed so that mask repair of 0.25 μm features can be considered. However, a better understanding of the materials science aspects of x-ray mask repair will help to advance the state-of-the-art.

1998 ◽  
Vol 4 (S2) ◽  
pp. 856-857
Author(s):  
David M. Longo ◽  
James M. Howe ◽  
William C. Johnson

The focused ion beam (FIB) has become an indispensable tool for a variety of applications in materials science, including that of specimen preparation for the transmission electron microscope (TEM). Several FIB specimen preparation techniques have been developed, but some problems result when FIB specimens are analyzed in the TEM. One of these is X-ray fluorescence from bulk material surrounding the thin membrane in FIB-prepared samples. This paper reports on a new FIB specimen preparation method which was devised for the reduction of X-ray fluorescence during energy dispersive X-ray spectroscopy (EDS) in the TEM.Figure 1 shows three membrane geometries that were investigated in this study on a single-crystal Si substrate with a RF sputter-deposited 50 nm Ni film. Membrane 1 is the most commonly reported geometry in the literature, with an approximately 20 urn wide trench and a membrane having a single wedge with a 1.5° incline.


2018 ◽  
Author(s):  
C.S. Bonifacio ◽  
P. Nowakowski ◽  
M.J. Campin ◽  
M.L. Ray ◽  
P.E. Fischione

Abstract Transmission electron microscopy (TEM) specimens are typically prepared using the focused ion beam (FIB) due to its site specificity, and fast and accurate thinning capabilities. However, TEM and high-resolution TEM (HRTEM) analysis may be limited due to the resulting FIB-induced artifacts. This work identifies FIB artifacts and presents the use of argon ion milling for the removal of FIB-induced damage for reproducible TEM specimen preparation of current and future fin field effect transistor (FinFET) technologies. Subsequently, high-quality and electron-transparent TEM specimens of less than 20 nm are obtained.


Author(s):  
T. Yaguchi ◽  
M. Konno ◽  
T. Kamino ◽  
M. Ogasawara ◽  
K. Kaji ◽  
...  

Abstract A technique for preparation of a pillar shaped sample and its multi-directional observation of the sample using a focused ion beam (FIB) / scanning transmission electron microscopy (STEM) system has been developed. The system employs an FIB/STEM compatible sample rotation holder with a specially designed rotation mechanism, which allows the sample to be rotated 360 degrees [1-3]. This technique was used for the three dimensional (3D) elemental mapping of a contact plug of a Si device in 90 nm technology. A specimen containing a contact plug was shaped to a pillar sample with a cross section of 200 nm x 200 nm and a 5 um length. Elemental analysis was performed with a 200 kV HD-2300 STEM equipped with the EDAX genesis Energy dispersive X-ray spectroscopy (EDX) system. Spectrum imaging combined with multivariate statistical analysis (MSA) [4, 5] was used to enhance the weak X-ray signals of the doped area, which contain a low concentration of As-K. The distributions of elements, especially the dopant As, were successfully enhanced by MSA. The elemental maps were .. reconstructed from the maps.


Author(s):  
Thomas M. Moore

Abstract The availability of the focused ion beam (FIB) microscope with its excellent imaging resolution, depth of focus and ion milling capability has made it an appealing platform for materials characterization at the sub-micron, or "nano" level. This article focuses on nanomechanical characterization in the FIB, which is an extension of the FIB capabilities into the realm of nano-technology. It presents examples that demonstrate the power and flexibility of nanomechanical testing in the FIB or scanning electron microscope with a probe shaft that includes a built-in strain gauge. Loads that range from grams to micrograms are achievable. Calibration is limited only by the availability of calibrated load cells in the smallest load ranges. Deflections in the range of a few nanometers range can be accurately applied. Simultaneous electrical, mechanical, and visual data can be combined to provide a revealing study of physical behavior of complex and dynamic nanostructures.


CORROSION ◽  
10.5006/3881 ◽  
2021 ◽  
Author(s):  
Zachary Karmiol ◽  
Dev Chidambaram

This work investigates the oxidation of a nickel based superalloy, namely Alloy X, in water at elevated temperatures: subcritical water at 261°C and 27 MPa, the transition between subcritical and supercritical water at 374°C and 27 MPa, and supercritical water at 380°C and 27 MPa for 100 hours. The morphology of the sample surfaces were studied using scanning electron microscopy coupled with focused ion beam milling, and the surface chemistry was investigated using X-ray diffraction, Raman spectroscopy, energy dispersive X-ray spectroscopy, and X-ray photoelectron spectroscopy before and after exposure studies. Surfaces of all samples were identified to comprise of a ferrite spinel containing aluminum.


2000 ◽  
Vol 6 (S2) ◽  
pp. 524-525 ◽  
Author(s):  
Michael W. Phaneuf ◽  
Jian Li

Focused ion beam (FIB) microscopes, the use of which is well established in the semiconductor industry, are rapidly gaining attention in the field of materials science, both as a tool for producing site specific, parallel sided TEM specimens and as a stand alone specimen preparation and imaging tool.Both FIB secondary ion images (FIB SII) and FIB secondary electron images (FIB SEI) contain novel crystallographic and chemical information. The ability to see “orientation contrast” in FIB SEI and to a lesser extent SII is well known for cubic materials and more recently stress-free FIB sectioning combined with FIB imaging have been shown to reveal evidence of plastic deformation in metallic specimens. Particularly in hexagonal metals, FIB orientation contrast is sometimes reduced or eliminated by the FIB sectioning process. We have successfully employed FIB gas assisted etching during FIB sectioning using XeF2 for zirconium alloys and Cl2 for zinc coatings on steels to retain orientation contrast during subsequent imaging.


1995 ◽  
Vol 396 ◽  
Author(s):  
P.G. Blauner ◽  
A. Wagner

AbstractThe ion beam induced metal deposition processes now employed by commercial focused ion beam (FIB) tools all demonstrate less than optimal characteristics for use in circuit repair, a major application of these tools. In particular, the processes have low efficiencies, the metals produced have poor conductivity, and some form of clean up is generally required to remove excess material surrounding the repair site. The gold deposition process developed for x-ray mask repair, in contrast, exhibits efficiencies 10-50 times higher with significantly less material deposited in unwanted areas. Unfortunately, the conductivity of the gold is even poorer than that of materials now used for FIB circuit repair.In this paper, an annealing step which improves the conductivity of FIB deposited Au is described. Results are presented demonstrating resistivities of 5-15 μΩ-cm while maintaining the high efficiency of the gold deposition process. The suitability of the process for use in FIB circuit repair is discussed.


2021 ◽  
Vol 134 (19) ◽  
Author(s):  
Valerie Panneels ◽  
Ana Diaz ◽  
Cornelia Imsand ◽  
Manuel Guizar-Sicairos ◽  
Elisabeth Müller ◽  
...  

ABSTRACT Ptychographic hard X-ray computed tomography (PXCT) is a recent method allowing imaging with quantitative electron-density contrast. Here, we imaged, at cryogenic temperature and without sectioning, cellular and subcellular structures of a chemically fixed and stained wild-type mouse retina, including axons and synapses, with complete isotropic 3D information over tens of microns. Comparison with tomograms of degenerative retina from a mouse model of retinitis pigmentosa illustrates the potential of this method for analyzing disease processes like neurodegeneration at sub-200 nm resolution. As a non-destructive imaging method, PXCT is very suitable for correlative imaging. Within the outer plexiform layer containing the photoreceptor synapses, we identified somatic synapses. We used a small region inside the X-ray-imaged sample for further high-resolution focused ion beam/scanning electron microscope tomography. The subcellular structures of synapses obtained with the X-ray technique matched the electron microscopy data, demonstrating that PXCT is a powerful scanning method for tissue volumes of more than 60 cells and sensitive enough for identification of regions as small as 200 nm, which remain available for further structural and biochemical investigations.


Sign in / Sign up

Export Citation Format

Share Document