Near-Field Performance Assessment for the Saltstone Disposal Facility

1992 ◽  
Vol 294 ◽  
Author(s):  
Roger R. Seitz ◽  
John C. Walton ◽  
Craig A. Dicke ◽  
James R. Cook

ABSTRACTA near-field performance assessment (PA) was conducted for the Saltstone Disposal Facility (SDF) at the Savannah River Site in South Carolina. The analysis was conducted in four parts: general screening calculations, degradation calculations, and flow and transport through the fractured and nonfractured facility. Modeling approaches and example sensitivity analysis results from the simulations of the fractured facility are discussed. Design considerations that may not be apparent without addressing flow and transport through fractures and lessons learned during the process are also presented.

Author(s):  
James K. Chan ◽  
John W. Ramsey

This paper describes the current pressure protection program at Savannah River Site (SRS), a Department of Energy chemical processing and nuclear material handling facility in Aiken, South Carolina. It gives a brief description of the design requirements based on ASME, API, CGA, and ASHRAE Codes. Equipment and systems requiring pressure protection at SRS are primarily pressure vessels, steam stations, process chemical systems, refrigerant and cryogenic systems and other air or gas systems. It is understood that any pressure protection program is built on five fundamental areas of responsibility: procurement, verification, registration, inspection, and repair. This paper focuses on the existing process of facility pressure protection evaluation for code compliance followed by identification of failure scenarios and system design requirements, valve selection and sizing, and verification record generation. Improvements to this process are recognized and discussed. They include the development of a computer program to perform pressure protection evaluation and generate verification records. The software would process all applicable pressure protection calculations using improved methodologies. All relevant data required would be accessible within the program. Pressure safety relief device attributes and system parameters would be displayed. The computer program would enhance design consistency, improve quality and plant safety, and make the pressure protection verification process more efficient and cost effective.


Hydrobiologia ◽  
1994 ◽  
Vol 279-280 (1) ◽  
pp. 71-82 ◽  
Author(s):  
Keith L. Bildstein ◽  
Dale E. Gawlik ◽  
Dan P. Ferral ◽  
I. Lehr Brisbin ◽  
Gary R. Wein

Sign in / Sign up

Export Citation Format

Share Document