Determination of the Forward Rate of Dissolution for SON68 and PAMELA Glasses in Contact With Alkaline Solutions

2008 ◽  
Vol 1107 ◽  
Author(s):  
K. Ferrand ◽  
K. Lemmens

AbstractIn the new Belgian disposal design, the nuclear waste glass will be surrounded by a 3 cm thick carbon steel overpack and a 70 cm thick concrete buffer. An initially high pH is expected after water intrusion in the concrete buffer and this may have an effect on the radionuclide release from the waste glass. This study was performed in order to determine the forward rate of dissolution for SON68 and PAMELA glasses (SM513 LW11 and SM539 HE 540-12), conducting dynamic tests at 30°C in contact with alkaline solutions. In these experiments, the silicon concentration in solution was determined by UV/Visible spectrophotometry according to the blue â-silicomolybdenum method. The forward rates of dissolution were quite similar for the three glasses except at the highest pH for which a slightly higher value was found for SM539 glass. For SON68 glass, a good agreement with the previously established interpolation law was observed until pH 11.5, but at higher pH, the interpolation law slightly overestimates the dissolution rate [1].

MRS Advances ◽  
2017 ◽  
Vol 2 (12) ◽  
pp. 661-667 ◽  
Author(s):  
Alice Elia ◽  
Karine Ferrand ◽  
Karel Lemmens

ABSTRACTThe International Simple Glass (ISG) is considered as reference benchmark glass and is used in the frame of an international collaboration for the study of the dissolution mechanisms of high-level vitrified nuclear waste.In this work the forward dissolution rate of the ISG was determined in different alkaline solutions, as a simulation of the disposal conditions foreseen by the Belgian concept for geological disposal of vitrified waste. The determination of the forward dissolution rate was done by measuring the Si released from the glass in solution in tests performed at 30 °C in four different KOH solutions with pH varying from 9 to 14 and in artificial cementitious water at pH 13.5.The forward dissolution rates determined for the ISG in high pH solutions are in good agreement with the results obtained for a lower pH range.The rates obtained in this study, moreover, were compared with the rates measured in the same conditions for SON68 glass from a previous work. The values obtained for the two glasses are comparable in artificial cementitious water and in KOH at moderately alkaline pH. At higher pH, ISG glass shows a lower forward dissolution rate with respect to SON68 (0.20 g·m-2·d for ISG and 0.35 g·m-2 d for SON68 at pH 14).


2017 ◽  
Vol 36 (4) ◽  
pp. 62 ◽  
Author(s):  
M. Tubino ◽  
L. F. Bianchessi ◽  
M. Palumbo ◽  
M. M.D.C. Vila

Two quantitative analytical methods for the determination of nitrofurantoin in pharmaceutical preparations in the visible-ultraviolet range of the spectrum are reported. One of them uses the diffuse reflectance technique and the other transmittance measurements in aqueous solution. Both procedures are very simple to be performed and also present green characteristics as only polyethylene glycol and water are used as solvents. Commercial pharmaceutical preparations of the drug were analyzed using the proposed methods. The results were compared with those obtained when the HPLC procedure recommended by the USP was applied. Statistical comparison using the paired Student’s t test and the Snedecor’s F test showed good agreement between all the methods.


MRS Advances ◽  
2019 ◽  
Vol 4 (17-18) ◽  
pp. 993-999
Author(s):  
Adam J. Fisher ◽  
Neil C. Hyatt ◽  
Russell J. Hand ◽  
Claire L. Corkhill

ABSTRACTThe forward rate of dissolution of the International Simple Glass (ISG) was determined under alkaline conditions at 40 °C using the Single Pass Flow Through (SPFT) method. Forward rates were consistent with those obtained in the literature for this glass composition. The formation of altered gel layers and surface pits was observed on the surface of glass particles, especially at the very highest pH values, despite the application of high flow rates to prevent the build-up of solubility limiting phases. These features could be attributed to preferential localized dissolution at sites with a higher alkali concentration or from a separate, less durable, vitreous phase. These results may indicate that surface pit and altered gel formation occurs under the forward rate of dissolution as imposed by the SPFT method, particularly for simplified borosilicate glass materials.


1969 ◽  
Vol 62 (4) ◽  
pp. 663-670 ◽  
Author(s):  
Lars Carlborg

ABSTRACT Oestrogens administered in lower doses than necessary to induce full cornification of the mouse vagina induce mucification. It was shown previously that the degree of mucification could be estimated by quantitative determination of sialic acids. A suitable parameter for oestrogen assay was the measurement of vaginal sialic acid concentration which exhibited a clear cut dose response curve. Eleven assays of various oestrogens were performed with this method. Their estimated relative potencies were in good agreement with other routine oestrogen assays. A statistically sufficient degree of precision was found. The sensitivity was of the same order, or slightly higher, than the Allen-Doisy test.


1967 ◽  
Vol 13 (6) ◽  
pp. 515-520 ◽  
Author(s):  
Genevieve Farese ◽  
Janice L Schmidt ◽  
Milton Mager

Abstract A completely automated analysis is described for the determination of serum calcium with glyoxal bis (2-hydroxyanil) solution (GBHA). The method is simple and precise, and the data obtained are in good agreement with results obtained by the manual GBHA procedure.


Author(s):  
Emre Kahramanoglu ◽  
Silvia Pennino ◽  
Huseyin Yilmaz

The hydrodynamic characteristics of the planing hulls in particular at the planing regime are completely different from the conventional hull forms and the determination of these characteristics is more complicated. In the present study, calm water hydrodynamic characteristics of planing hulls are investigated using a hybrid method. The hybrid method combines the dynamic trim and sinkage from the Zarnick approach with the Savitsky method in order to calculate the total resistance of the planing hull. Since the obtained dynamic trim and sinkage values by using the original Zarnick approach are not in good agreement with experimental data, an improvement is applied to the hybrid method using a reduction function proposed by Garme. The numerical results obtained by the hybrid and improved hybrid method are compared with each other and available experimental data. The results indicate that the improved hybrid method gives better results compared to the hybrid method, especially for the dynamic trim and resistance. Although the results have some discrepancies with experimental data in terms of resistance, trim and sinkage, the improved hybrid method becomes appealing particularly for the preliminary design stage of the planing hulls.


Sensors ◽  
2021 ◽  
Vol 21 (10) ◽  
pp. 3567
Author(s):  
Beata Szymanska ◽  
Zenon Lukaszewski ◽  
Beata Zelazowska-Rutkowska ◽  
Kinga Hermanowicz-Szamatowicz ◽  
Ewa Gorodkiewicz

Human epididymis protein 4 (HE4) is an ovarian cancer marker. Various cut-off values of the marker in blood are recommended, depending on the method used for its determination. An alternative biosensor for HE4 determination in blood plasma has been developed. It consists of rabbit polyclonal antibody against HE4, covalently attached to a gold chip via cysteamine linker. The biosensor is used with the non-fluidic array SPRi technique. The linear range of the analytical signal response was found to be 2–120 pM, and the biosensor can be used for the determination of the HE4 marker in the plasma of both healthy subjects and ovarian cancer patients after suitable dilution with a PBS buffer. Precision (6–10%) and recovery (101.8–103.5%) were found to be acceptable, and the LOD was equal to 2 pM. The biosensor was validated by the parallel determination of a series of plasma samples from ovarian cancer patients using the Elecsys HE4 test and the developed biosensor, with a good agreement of the results (a Pearson coefficient of 0.989). An example of the diagnostic application of the developed biosensor is given—the influence of ovarian tumor resection on the level of HE4 in blood serum.


Molecules ◽  
2021 ◽  
Vol 26 (12) ◽  
pp. 3627
Author(s):  
Nikola Sakač ◽  
Dubravka Madunić-Čačić ◽  
Dean Marković ◽  
Lucija Hok ◽  
Robert Vianello ◽  
...  

A 1,3-dihexadecyl-1H-benzo[d]imidazol-3-ium-tetraphenylborate (DHBI-TPB) ion-pair implemented in DHBI-TPB surfactant sensor was used for the potentiometric quantification of anionic surfactants in detergents and commercial household care products. The DHBI-TPB ion-pair was characterized by FTIR spectroscopy and computational analysis which revealed a crucial contribution of the C–H∙∙∙π contacts for the optimal complex formation. The DHBI-TPB sensor potentiometric response showed excellent analytical properties and Nernstian slope for SDS (60.1 mV/decade) with LOD 3.2 × 10−7 M; and DBS (58.4 mV/decade) with LOD 6.1 × 10−7 M was obtained. The sensor possesses exceptional resistance to different organic and inorganic interferences in broad pH (2–10) range. DMIC used as a titrant demonstrated superior analytical performances for potentiometric titrations of SDS, compared to other tested cationic surfactants (DMIC > CTAB > CPC > Hyamine 1622). The combination of DHBI-TPB sensor and DMIC was successfully employed to perform titrations of the highly soluble alkane sulfonate homologues. Nonionic surfactants (increased concentration and number of EO groups) had a negative impact on anionic surfactant titration curves and a signal change. The DHBI-TPB sensor was effectively employed for the determination of technical grade anionic surfactants presenting the recoveries from 99.5 to 101.3%. The sensor was applied on twelve powered samples as well as liquid-gel and handwashing home care detergents containing anionic surfactants. The obtained results showed good agreement compared to the outcomes measured by ISE surfactant sensor and a two-phase titration method. The developed DHBI-TPB surfactant sensor could be used for quality control in industry and has great potential in environmental monitoring.


Molecules ◽  
2020 ◽  
Vol 25 (17) ◽  
pp. 3963
Author(s):  
Jizhou Wu ◽  
Jie Ma ◽  
Yuqing Li ◽  
Wenliang Liu ◽  
Peng Li ◽  
...  

This article demonstrates new observation of the high-resolution ro-vibrational bichromatic photoassociation spectra (BPAS) of Cs2 in the 0u+ long-range state below the asymptotes 6S1/2 + 6P1/2. By combining with a modulation spectroscopic technique, precise references of the frequency differences have been engineered through the BPAS, with which the rotational constants of low-lying vibrational levels of the Cs20u+ long-range state have been accurately determined by fitting the frequency differences to the non-rigid-rotor model. The rotational constants for the newly observed seven ro-vibrational levels are summarized and disagreement for the level ῦ = 498 is clarified. The rotational constants of different vibrational levels demonstrate strong perturbations of the related energy structures. A simple analysis is performed and shows good agreement with experimental results.


2009 ◽  
Vol 9 (11) ◽  
pp. 3641-3662 ◽  
Author(s):  
D. Chen ◽  
B. Zhou ◽  
S. Beirle ◽  
L. M. Chen ◽  
T. Wagner

Abstract. Zenith-sky scattered sunlight observations using differential optical absorption spectroscopy (DOAS) technique were carried out in Shanghai, China (31.3° N, 121.5° E) since December 2006. At this polluted urban site, the measurements provided NO2 total columns in the daytime. Here, we present a new method to extract time series of tropospheric vertical column densities (VCDs) of NO2 from these observations. The derived tropospheric NO2 VCDs are important quantities for the estimation of emissions and for the validation of satellite observations. Our method makes use of assumptions on the relative NO2 height profiles and the diurnal variation of stratospheric NO2 VCDs. The main error sources arise from the uncertainties in the estimated stratospheric slant column densities (SCDs) and the determination of tropospheric NO2 air mass factor (AMF). For a polluted site like Shanghai, the accuracy of our method is conservatively estimated to be <25% for solar zenith angle (SZA) lower than 70°. From simultaneously performed long-path DOAS measurements, the NO2 surface concentrations at the same site were observed and the corresponding tropospheric NO2 VCDs were estimated using the assumed seasonal NO2 profiles in the planetary boundary layer (PBL). By making a comparison between the tropospheric NO2 VCDs from zenith-sky and long-path DOAS measurements, it is found that the former provides more realistic information about total tropospheric pollution than the latter, so it's more suitable for satellite data validation. A comparison between the tropospheric NO2 VCDs from ground-based zenith-sky measurements and SCIAMACHY was also made. Satellite validation for a strongly polluted area is highly needed, but exhibits also a great challenge. Our comparison shows good agreement, considering in particular the different spatial resolutions between the two measurements. Remaining systematic deviations are most probably related to the uncertainties of satellite data caused by the assumptions on aerosol properties as well as the layer heights of aerosols and NO2.


Sign in / Sign up

Export Citation Format

Share Document