Formation of Double Layered SOI With Controlled Crystal Orientation

1987 ◽  
Vol 107 ◽  
Author(s):  
Toshiaki Miyajima ◽  
Hideyuki Tsuji ◽  
Masashi Maekawa ◽  
Masayoshi Koba

AbstractFor the crystal orientation control of multi-layered SOI (Silicon on Insulator) by the laser recrystallization technology, the shape and size of seeds were investigated. By utilizing dot seeds less than 3μm square instead of a line seed, the crystal orientation control of a SOI layer was successfully realized without causing evaporation of silicon. Moreover, the dot seed method enabled us to control the crystal orientation of multi-layered SOI by virtue of small heat flow through seed regions.In the mean time, it was proved that the SOI crystal orientation gradually rotated as the crystal propagated away from the seeds and that the degree of rotation in the second SOI layer was smaller than that in the first one.

1996 ◽  
Vol 75 (05) ◽  
pp. 731-733 ◽  
Author(s):  
V Cazaux ◽  
B Gauthier ◽  
A Elias ◽  
D Lefebvre ◽  
J Tredez ◽  
...  

SummaryDue to large inter-individual variations, the dose of vitamin K antagonist required to target the desired hypocoagulability is hardly predictible for a given patient, and the time needed to reach therapeutic equilibrium may be excessively long. This work reports on a simple method for predicting the daily maintenance dose of fluindione after the third intake. In a first step, 37 patients were delivered 20 mg of fluindione once a day, at 6 p.m. for 3 consecutive days. On the morning of the 4th day an INR was performed. During the following days the dose was adjusted to target an INR between 2 and 3. There was a good correlation (r = 0.83, p<0.001) between the INR performed on the morning of day 4 and the daily maintenance dose determined later by successive approximations. This allowed us to write a decisional algorithm to predict the effective maintenance dose of fluindione from the INR performed on day 4. The usefulness and the safety of this approach was tested in a second prospective study on 46 patients receiving fluindione according to the same initial scheme. The predicted dose was compared to the effective dose soon after having reached the equilibrium, then 30 and 90 days after. To within 5 mg (one quarter of a tablet), the predicted dose was the effective dose in 98%, 86% and 81% of the patients at the 3 times respectively. The mean time needed to reach the therapeutic equilibrium was reduced from 13 days in the first study to 6 days in the second study. No hemorrhagic complication occurred. Thus the strategy formerly developed to predict the daily maintenance dose of warfarin from the prothrombin time ratio or the thrombotest performed 3 days after starting the treatment may also be applied to fluindione and the INR measurement.


2002 ◽  
pp. 337-378 ◽  
Author(s):  
Jozef Telega ◽  
Wlodzimierz Bielski

The aim of this contribution is mainly twofold. First, the stochastic two-scale convergence in the mean developed by Bourgeat et al. [13] is used to derive the macroscopic models of: (i) diffusion in random porous medium, (ii) nonstationary flow of Stokesian fluid through random linear elastic porous medium. Second, the multi-scale convergence method developed by Allaire and Briane [7] for the case of several microperiodic scales is extended to random distribution of heterogeneities characterized by separated scales (stochastic reiterated homogenization). .


1983 ◽  
Vol 48 (8) ◽  
pp. 2232-2248 ◽  
Author(s):  
Ivo Roušar ◽  
Michal Provazník ◽  
Pavel Stuhl

In electrolysers with recirculation, where a gas is evolved, the pumping of electrolyte from a lower to a higher level can be effected by natural convection due to the difference between the densities of the inlet electrolyte and the gaseous emulsion at the outlet. An accurate balance equation for calculation of the rate of flow of the pumped liquid is derived. An equation for the calculation of the mean volume fraction of bubbles in the space between the electrodes is proposed and verified experimentally on a pilot electrolyser. Two examples of industrial applications are presented.


2021 ◽  
Vol 121 ◽  
pp. 235-242
Author(s):  
Andreas Paul ◽  
Elmar Baumhögger ◽  
Andreas Elsner ◽  
Lukas Moczarski ◽  
Michael Reineke ◽  
...  
Keyword(s):  

2021 ◽  
pp. 107815522110160
Author(s):  
Bernadatte Zimbwa ◽  
Peter J Gilbar ◽  
Mark R Davis ◽  
Srinivas Kondalsamy-Chennakesavan

Purpose To retrospectively determine the rate of death occurring within 14 and 30 days of systemic anticancer therapy (SACT), compare this against a previous audit and benchmark results against other cancer centres. Secondly, to determine if the introduction of immune checkpoint inhibitors (ICI), not available at the time of the initial audit, impacted mortality rates. Method All adult solid tumour and haematology patients receiving SACT at an Australian Regional Cancer Centre (RCC) between January 2016 and July 2020 were included. Results Over a 55-month period, 1709 patients received SACT. Patients dying within 14 and 30 days of SACT were 3.3% and 7.0% respectively and is slightly higher than our previous study which was 1.89% and 5.6%. Mean time to death was 15.5 days. Males accounted for 63.9% of patients and the mean age was 66.8 years. 46.2% of the 119 patients dying in the 30 days post SACT started a new line of treatment during that time. Of 98 patients receiving ICI, 22.5% died within 30 days of commencement. Disease progression was the most common cause of death (79%). The most common place of death was the RCC (38.7%). Conclusion The rate of death observed in our re-audit compares favourably with our previous audit and is still at the lower end of that seen in published studies in Australia and internationally. Cases of patients dying within 30 days of SACT should be regularly reviewed to maintain awareness of this benchmark of quality assurance and provide a feedback process for clinicians.


2021 ◽  
pp. 1-7
Author(s):  
Naomi Vather-Wu ◽  
Matthew D. Krasowski ◽  
Katherine D. Mathews ◽  
Amal Shibli-Rahhal

Background: Expert guidelines recommend annual monitoring of 25-hydroxyvitamin D (25-OHD) and maintaining 25-OHD ≥30 ng/ml in patients with dystrophinopathies. Objective: We hypothesized that 25-OHD remains stable and requires less frequent monitoring in patients taking stable maintenance doses of vitamin D. Methods: We performed a retrospective cohort study, using the electronic health record to identify 26 patients with dystrophinopathies with a baseline 25-OHD ≥30 ng/mL and at least one additional 25-OHD measurement. These patients had received a stable dose of vitamin D for ≥3 months prior to their baseline 25-OHD measurement and throughout follow-up. The main outcome measured was the mean duration time the subjects spent with a 25-OHD ≥30 ng/mL. Results: Only 19% of patients dropped their 25-OHD to <  30 ng/ml, with a mean time to drop of 33 months and a median nadir 25-OHD of 28 ng/mL. Conclusions: These results suggest that measurement of 25-OHD every 2–2.5 years may be sufficient in patients with a baseline 25-OHD ≥30 ng/mL and who are on a stable maintenance dose of vitamin D. Other patients may require more frequent assessments.


Electronics ◽  
2021 ◽  
Vol 10 (8) ◽  
pp. 876
Author(s):  
Igor Gonçalves ◽  
Laécio Rodrigues ◽  
Francisco Airton Silva ◽  
Tuan Anh Nguyen ◽  
Dugki Min ◽  
...  

Surveillance monitoring systems are highly necessary, aiming to prevent many social problems in smart cities. The internet of things (IoT) nowadays offers a variety of technologies to capture and process massive and heterogeneous data. Due to the fact that (i) advanced analyses of video streams are performed on powerful recording devices; while (ii) surveillance monitoring services require high availability levels in the way that the service must remain connected, for example, to a connection network that offers higher speed than conventional connections; and that (iii) the trust-worthy dependability of a surveillance system depends on various factors, it is not easy to identify which components/devices in a system architecture have the most impact on the dependability for a specific surveillance system in smart cities. In this paper, we developed stochastic Petri net models for a surveillance monitoring system with regard to varying several parameters to obtain the highest dependability. Two main metrics of interest in the dependability of a surveillance system including reliability and availability were analyzed in a comprehensive manner. The analysis results show that the variation in the number of long-term evolution (LTE)-based stations contributes to a number of nines (#9s) increase in availability. The obtained results show that the variation of the mean time to failure (MTTF) of surveillance cameras exposes a high impact on the reliability of the system. The findings of this work have the potential of assisting system architects in planning more optimized systems in this field based on the proposed models.


Sign in / Sign up

Export Citation Format

Share Document