Archaeometrical Studies of Classic Mayan Mural Painting at Peten: La Blanca and Chilonche

2014 ◽  
Vol 1618 ◽  
pp. 45-62
Author(s):  
Mª Luisa Vázquez de Ágredos Pascual ◽  
Cristina Vidal Lorenzo ◽  
Gaspar Muñoz Cosme

ABSTRACTLa Blanca and Chilonche are two of the many Mayan settlements located on the lower reaches of the Mopan river (Department of Petén, Guatemala). The archaeological work conducted by La Blanca Project (University of Valencia, Spain) over the last ten years has revealed the rich polychrome of the monumental architecture of these sites, where the remains of ancient mural paintings are of the highest quality.In order to ascertain the materials and techniques used by painters at each site throughout the Classic period, our research team has recently conducted an analytical study with a multi-technique approach based on the combination of several non destructive and micro-destructive instrumental techniques, namely, light microscopy (LM), scanning electron microscopy-X-ray microanalysis (SEM/EDX), transmission electron microscopy (TEM), voltammetry of microparticles (VMP), X-ray microdiffraction (mXRD), X-ray diffraction (XRD), UVeVis spectrophotometry, FTIR spectroscopy and gas chromatographyemass spectrometry (GCeMS). These instrumental techniques provide reliable and complementary data, such as elemental and mineralogical composition, the identification of functional groups as well as specialization studies of electroactive species.This paper presents the results obtained at the Laboratories for the Analysis of Works of Art at the University of Valencia (Spain) and the Polytechnic University of Valencia (Spain) after chemically comparing the pigments and mural painting techniques of both Maya archaeological sites.

Clay Minerals ◽  
2009 ◽  
Vol 44 (2) ◽  
pp. 221-237 ◽  
Author(s):  
R. Yongue–Fouateu ◽  
M. Yemefack ◽  
A. S. L. Wouatong ◽  
P. D. Ndjigui ◽  
P. Bilong

AbstractFour drill cores along a lateritic hill in Nkamouna-Kongo (southeast Cameroon) were studied using microprobe analysis, X-ray diffraction, scanning electron microscopy, transmission electron microscopy and infrared spectroscopy. The main objective of the study was to investigate the occurrence of clay silicates while evaluating the Ni-Co content of the laterite for potential mineral exploitation. The thick lateritic profiles (>40 m deep) developed on serpentinized ultramafic rocks have an Fe-rich clayey fraction, with goethite as the main mineralogical constituent and secondary quartz and relicts of magnetite-maghemite as accessory minerals. Silicate clays are less abundant and occur mainly towards the top of the profiles. At the summit of the interfluve, kaolinite and some gibbsite are associated with goethite. Along the slopes, at the bottom of profiles, the weathered bedrock shows the presence of smectite (Fe-beidellite) and kaolinite, probably due to slower water-flow conditions. Towards the top of the profile in the lower clay, ferruginous and upper clay horizons, only kaolinite remains with gibbsite, after the leaching of silica and soluble cations following repeated remobilization-recrystallization processes. At the summit, where the downward movement of water is rapid, no smectite was identified. As a whole, the mineralogical composition of the material varies in close relationship with the drainage, leading to a contrasted clay mineralogy marked by the presence of Fe-beidellite and kaolinite at the bottom, and that of kaolinite and gibbsite at the summit of the profiles.


Author(s):  
S. Fujishiro

The mechanical properties of three titanium alloys (Ti-7Mo-3Al, Ti-7Mo- 3Cu and Ti-7Mo-3Ta) were evaluated as function of: 1) Solutionizing in the beta field and aging, 2) Thermal Mechanical Processing in the beta field and aging, 3) Solutionizing in the alpha + beta field and aging. The samples were isothermally aged in the temperature range 300° to 700*C for 4 to 24 hours, followed by a water quench. Transmission electron microscopy and X-ray method were used to identify the phase formed. All three alloys solutionized at 1050°C (beta field) transformed to martensitic alpha (alpha prime) upon being water quenched. Despite this heavily strained alpha prime, which is characterized by microtwins the tensile strength of the as-quenched alloys is relatively low and the elongation is as high as 30%.


Author(s):  
Benjamin F. Trump ◽  
Irene K. Berezesky ◽  
Raymond T. Jones

The role of electron microscopy and associated techniques is assured in diagnostic pathology. At the present time, most of the progress has been made on tissues examined by transmission electron microscopy (TEM) and correlated with light microscopy (LM) and by cytochemistry using both plastic and paraffin-embedded materials. As mentioned elsewhere in this symposium, this has revolutionized many fields of pathology including diagnostic, anatomic and clinical pathology. It began with the kidney; however, it has now been extended to most other organ systems and to tumor diagnosis in general. The results of the past few years tend to indicate the future directions and needs of this expanding field. Now, in addition to routine EM, pathologists have access to the many newly developed methods and instruments mentioned below which should aid considerably not only in diagnostic pathology but in investigative pathology as well.


Author(s):  
Mircea Fotino

A new 1-MeV transmission electron microscope (Model JEM-1000) was installed at the Department of Molecular, Cellular and Developmental Biology of the University of Colorado in Boulder during the summer and fall of 1972 under the sponsorship of the Division of Research Resources of the National Institutes of Health. The installation was completed in October, 1972. It is installed primarily for the study of biological materials without many of the limitations hitherto unavoidable in standard transmission electron microscopy. Only the technical characteristics of the installation are briefly reviewed here. A more detailed discussion of the experimental program under way is being published elsewhere.


Author(s):  
R. Gronsky

The phenomenon of clustering in Al-Ag alloys has been extensively studied since the early work of Guinierl, wherein the pre-precipitation state was characterized as an assembly of spherical, ordered, silver-rich G.P. zones. Subsequent x-ray and TEM investigations yielded results in general agreement with this model. However, serious discrepancies were later revealed by the detailed x-ray diffraction - based computer simulations of Gragg and Cohen, i.e., the silver-rich clusters were instead octahedral in shape and fully disordered, atleast below 170°C. The object of the present investigation is to examine directly the structural characteristics of G.P. zones in Al-Ag by high resolution transmission electron microscopy.


Author(s):  
Vicki L. Baliga ◽  
Mary Ellen Counts

Calcium is an important element in the growth and development of plants and one form of calcium is calcium oxalate. Calcium oxalate has been found in leaf seed, stem material plant tissue culture, fungi and lichen using one or more of the following methods—polarized light microscopy (PLM), scanning electron microscopy (SEM), transmission electron microscopy (TEM) and x-ray diffraction.Two methods are presented here for qualitatively estimating calcium oxalate in dried or fixed tobacco (Nicotiana) leaf from different stalk positions using PLM. SEM, coupled with energy dispersive x-ray spectrometry (EDS), and powder x-ray diffraction were used to verify that the crystals observed in the dried leaf with PLM were calcium oxalate.


Author(s):  
William P. Wergin ◽  
P. F. Bell ◽  
Rufus L. Chaney

In dicotyledons, Fe3+ must be reduced to Fe2+ before uptake and transport of this essential macronutrient can occur. Ambler et al demonstrated that reduction along the root could be observed by the formation of a stain, Prussian blue (PB), Fe4 [Fe(CN)6]3 n H2O (where n = 14-16). This stain, which is an insoluble precipitate, forms at the reduction site when the nutrient solution contains Fe3+ and ferricyanide. In 1972, Chaney et al proposed a model which suggested that the Fe3+ reduction site occurred outside the cell membrane; however, no physical evidence to support the model was presented at that time. A more recent study using the PB stain indicates that rapid reduction of Fe3+ occurs in a region of the root containing young root hairs. Furthermore the most pronounced activity occurs in plants that are deficient in Fe. To more precisely localize the site of Fe3+ reduction, scanning electron microscopy (SEM), x-ray analysis, and transmission electron microscopy (TEM) were utilized to examine the distribution of the PB precipitate that was induced to form in roots.


Author(s):  
J. R. Michael ◽  
K. A. Taylor

Although copper is considered an incidental or trace element in many commercial steels, some grades contain up to 1-2 wt.% Cu for precipitation strengthening. Previous electron microscopy and atom-probe/field-ion microscopy (AP/FIM) studies indicate that the precipitation of copper from ferrite proceeds with the formation of Cu-rich bcc zones and the subsequent transformation of these zones to fcc copper particles. However, the similarity between the atomic scattering amplitudes for iron and copper and the small misfit between between Cu-rich particles and the ferrite matrix preclude the detection of small (<5 nm) Cu-rich particles by conventional transmission electron microscopy; such particles have been imaged directly only by FIM. Here results are presented whereby the Cu Kα x-ray signal was used in a dedicated scanning transmission electron microscope (STEM) to image small Cu-rich particles in a steel. The capability to detect these small particles is expected to be helpful in understanding the behavior of copper in steels during thermomechanical processing and heat treatment.


Author(s):  
Marc J.C. de Jong ◽  
Wim M. Busing ◽  
Max T. Otten

Biological materials damage rapidly in the electron beam, limiting the amount of information that can be obtained in the transmission electron microscope. The discovery that observation at cryo temperatures strongly reduces beam damage (in addition to making it unnecessaiy to use chemical fixatives, dehydration agents and stains, which introduce artefacts) has given an important step forward to preserving the ‘live’ situation and makes it possible to study the relation between function, chemical composition and morphology.Among the many cryo-applications, the most challenging is perhaps the determination of the atomic structure. Henderson and co-workers were able to determine the structure of the purple membrane by electron crystallography, providing an understanding of the membrane's working as a proton pump. As far as understood at present, the main stumbling block in achieving high resolution appears to be a random movement of atoms or molecules in the specimen within a fraction of a second after exposure to the electron beam, which destroys the highest-resolution detail sought.


Author(s):  
Kenichi Takaya

Mast cell and basophil granules of the vertebrate contain heparin or related sulfated proteoglycans. Histamine is also present in mammalian mast cells and basophils. However, no histamine is detected in mast cell granules of the amphibian or fish, while it is shown in those of reptiles and birds A quantitative x-ray microanalysis of mast cell granules of fresh frozen dried ultrathin sections of the tongue of Wistar rats and tree frogs disclosed high concentrations of sulfur in rat mast cell granules and those of sulfur and magnesium in the tree frog granules. Their concentrations in tree frog mast cell granules were closely correlated (r=0.94).Fresh frozen dried ultrathin sections and fresh air-dried prints of the tree frog tongue and spleen and young red-eared turtle (ca. 6 g) spleen and heart blood were examined by a quantitative energy-dispersive x-ray microanalysis (X-650, Kevex-7000) for the element constituents of the granules of mast cells and basophils. The specimens were observed by transmission electron microscopy (TEM) (80-200 kV) and followed by scanning transmission electron microscopy (STEM) under an analytical electron microscope (X-650) at an acceleration voltage of 40 kV and a specimen current of 0.2 nA. A spot analysis was performed in a STEM mode for 100 s at a specimen current of 2 nA on the mast cell and basophil granules and other areas of the cells. Histamine was examined by the o-phthalaldehyde method.


Sign in / Sign up

Export Citation Format

Share Document