scholarly journals Long-Term Screening is Necessary in Patients with Metal on Metal Total Hip Arthroplasty

2019 ◽  
Vol 9 ◽  
Author(s):  
J. Ryan Martin ◽  
Susan Odum ◽  
William Griffin

Introduction: Adverse reactions to metal debris with catastrophic failures have been seen with a number of metal on metal (MoM) total hip designs. Understanding survivorship and factors associated with failure will allow for more targeted surveillance of those patients at highest risk for failure. The purpose of this study was to assess the mid to long term survivorship and specific factors associated with failure for a large cohort of a single modular MoM design.Methods: Consecutive patients treated with a modular metal on metal bearing with a five to fourteen year follow-up were included. Clinical outcome scores and radiographic data were prospectively collected.  Failure was defined as revision of either component for any reason during the study period. Multiple implant, surgical, and patient factors were analyzed for associations with elevated ion levels or revision due to adverse reactions to metal debris.Results: The average age at the time of surgery for the 253 patients included in the study was 55. There were 28 revisions (7.5%), eight due to metallosis (2%).   Survivorship was 89% at 12.6 years with revision for any reason as the end point. Survivorship was 93% when limited to revision for ALTR as the end point. Time in situ was the only variable that was statistically associated with an increased risk of failure due to ALTR (p<0.0001)Conclusion: In this large series of a single design modular metal-metal total hip we found relatively low rates of revision due to adverse reactions to metal debris.  The only variable associated with a statistically significant risk of ALTR was time in situ.   Therefore, long-term surveillance is necessary in patients with a MoM THA.

2021 ◽  
Vol 9 ◽  
pp. 205031212110147
Author(s):  
Nobuhiko Sumiyoshi ◽  
Kazuhiro Oinuma ◽  
Yoko Miura

Background: Adverse reactions to metal debris are significant complications after metal-on-metal total hip arthroplasty. Recently, late appearances of adverse reactions to metal debris and subsequent need for reoperations have been reported with small-diameter head metal-on-metal devices. We retrospectively investigated mid-term clinical outcomes of small-head metal-on-metal total hip arthroplasty. Methods: We reviewed 159 hips in 139 patients who had a small-head metal-on-metal total hip arthroplasty (M2a Taper; Biomet, Warsaw, IN) with a minimum 5-year follow-up and documented postoperative complications. Results: Focal osteolysis in either the femur or acetabulum was observed in 12 hips (7.5%, 44 months after surgery on average), with pseudotumor observed in 8 hips (5%, 120 months after surgery on average). Four hips (2.5%) had dislocations (84 months after surgery on average) and six hips (3.8%, 122 months after surgery on average) underwent reoperation. Conclusion: Small-head metal-on-metal total hip arthroplasty is associated with a high degree of complications at mid-term follow-up period. Considering this, we discourage the use of metal-on-metal total hip arthroplasty regardless of head size.


2021 ◽  
Vol 11 ◽  
Author(s):  
Jonathan Liu ◽  
Alister Hart ◽  
Brendan Holderread ◽  
Terry Clyburn

Metal-on-metal (MoM) hip arthroplasty was re-popularized in the 1990s to resolve osteolysis and wear associated with metal-on-polyethylene products. Despite early success, registries began reporting high failure rates due to adverse reactions to metal debris (ARMD), manifesting as pseudotumors, hip effusions and osteolysis. Evaluation includes clinical exam, advanced imaging, and blood metal ions and infectious markers. This review provides physicians with an evidence-based update on the 1) clinical workup and management of patients with existing MoM implants, 2) risk and prognostic factors associated with suboptimal results and 3) the precipitating events and lessons learned applicable to future orthopedic prosthesis.


2021 ◽  
Vol 80 (Suppl 1) ◽  
pp. 77-78
Author(s):  
S. Do ◽  
J. H. Du ◽  
J. X. An ◽  
J. Wang ◽  
A. Lin

Background:Hydroxychloroquine (HCQ) is commonly used for the treatment of various autoimmune diseases. The medication is generally well-tolerated. However, long-term use after 5 years may increase the risk of retinopathy. One study in 2014 has demonstrated the risk can be as high as 7.5%. Optical Coherence Tomography (OCT) has become a major modality in screening retinopathy.Objectives:To evaluate the prevalence of retinal toxicity among patients using hydroxychloroquine and to determine various risk factors associated with hydroxychloroquine-associated retinal toxicity.Methods:We performed a retrospective chart review on a cohort of adult patients with long-term use (≥ 5 years cumulative) of HCQ between January 1st, 2011 to December 31st, 2018 from the Kaiser Permanente San Bernardino County and Riverside medical center areas in Southern California, USA. Patients were excluded if they had previously been diagnosed with retinopathy prior to hydroxychloroquine use, were deceased, or had incomplete OCT exam. Our primary endpoint was the prevalence of patients who developed retinal toxicity detected by OCT, and later confirmed by retinal specialist. Potential risk factors (age, duration of therapy, daily consumption per actual body weight, cumulative dose, confounding diseases and medication) for developing retinopathy were also evaluated. Univariable and multivariable logistic regression analyses were used to determine risk factors associated with retinal toxicity.Results:Among 676 patients exposed to more than 5 years of HCQ, the overall prevalence of retinal toxicity was 6.8%, and ranged from 2.5% to 22.2% depending on the age, weight-based dosing, duration of use and cumulative dose. Duration of therapy for 10 years or more increased risk of retinopathy by approximately 5 to 19 folds. Similarly, weight-based dose of 7 mg/kg/day or greater was assciated with increased risk of retinopathy by approximately 5 times. Patients with cumulative dose of 2000 grams or more had greater than 15 times higher risk of developing retinopathy. Duration of use for10 years or more (odd ratio 4.32, 95% CI 1.99 – 12.49), age (odd ratio 1.04; 95% CI 1.01 - 1.08), cumulative dose of more than 1500 g (odd ratio 7.4; 95% CI 1.40 – 39.04) and atherosclerosis of the aorta (odd ratio 2.59; 95% CI, 1.24 – 5.41) correlated with higher risk of retinal toxicity.Conclusion:The overall prevalence of retinopathy was 6.8%. Regular OCT screening, especially in patients with hydroxychloroquine use for more than 10 years, daily intake > 7 mg/kg, or cumulative dose > 1500 grams is important in detecting hydroxychloroquine-associated retinal toxicityReferences:[1]Hobbs HE. Sorsby A, & Freedman A. Retinopathy Following Chloroquine Therapy. The Lancet. 1959; 2(7101): 478-480.[2]Levy, G. D., Munz, S. J., Paschal, J., Cohen, H. B., Pince, K. J., & Peterson, T. Incidence of hydroxychloroquine retinopathy in 1,207 patients in a large multicenter outpatient practice. Arthritis & Rheumatism: 1997; 40(8): 1482-1486.[3]Ding, H. J., Denniston, A. K., Rao, V. K., & Gordon, C. Hydroxychloroquine-related retinal toxicity. Rheumatology. 2016; 55(6): 957-967.[4]Stelton, C. R., Connors, D. B., Walia, S. S., & Walia, H. S. Hydrochloroquine retinopathy: characteristic presentation with review of screening. Clinical rheumatology. 2013; 32(6): 895-898.[5]Marmor, M. F., Kellner, U., Lai, T. Y., Melles, R. B., & Mieler, W. F. Recommendations on screening for chloroquine and hydroxychloroquine retinopathy (2016 revision). Ophthalmology. 2016; 123(6): 1386-1394.[6]Melles, R. B., & Marmor, M. F. The risk of toxic retinopathy in patients on long-term hydroxychloroquine therapy. JAMA ophthalmology. 2014; 132(12): 1453-1460.Disclosure of Interests:None declared


2022 ◽  
Vol 104-B (1) ◽  
pp. 45-52
Author(s):  
Liam Zen Yapp ◽  
Nick D. Clement ◽  
Matthew Moran ◽  
Jon V. Clarke ◽  
A. Hamish R. W. Simpson ◽  
...  

Aims The aim of this study was to determine the long-term mortality rate, and to identify factors associated with this, following primary and revision knee arthroplasty (KA). Methods Data from the Scottish Arthroplasty Project (1998 to 2019) were retrospectively analyzed. Patient mortality data were linked from the National Records of Scotland. Analyses were performed separately for the primary and revised KA cohorts. The standardized mortality ratio (SMR) with 95% confidence intervals (CIs) was calculated for the population at risk. Multivariable Cox proportional hazards were used to identify predictors and estimate relative mortality risks. Results At a median 7.4 years (interquartile range (IQR) 4.0 to 11.6) follow-up, 27.8% of primary (n = 27,474/98,778) and 31.3% of revision (n = 2,611/8,343) KA patients had died. Both primary and revision cohorts had lower mortality rates than the general population (SMR 0.74 (95% CI 0.73 to 0.74); p < 0.001; SMR 0.83 (95% CI 0.80 to 0.86); p < 0.001, respectively), which persisted for 12 and eighteight years after surgery, respectively. Factors associated with increased risk of mortality after primary KA included male sex (hazard ratio (HR) 1.40 (95% CI 1.36 to 1.45)), increasing socioeconomic deprivation (HR 1.43 (95% CI 1.36 to 1.50)), inflammatory polyarthropathy (HR 1.79 (95% CI 1.68 to 1.90)), greater number of comorbidities (HR 1.59 (95% CI 1.51 to 1.68)), and periprosthetic joint infection (PJI) requiring revision (HR 1.92 (95% CI 1.57 to 2.36)) when adjusting for age. Similarly, male sex (HR 1.36 (95% CI 1.24 to 1.49)), increasing socioeconomic deprivation (HR 1.31 (95% CI 1.12 to 1.52)), inflammatory polyarthropathy (HR 1.24 (95% CI 1.12 to 1.37)), greater number of comorbidities (HR 1.64 (95% CI 1.33 to 2.01)), and revision for PJI (HR 1.35 (95% 1.18 to 1.55)) were independently associated with an increased risk of mortality following revision KA when adjusting for age. Conclusion The SMR of patients undergoing primary and revision KA was lower than that of the general population and remained so for several years post-surgery. However, approximately one in four patients undergoing primary and one in three patients undergoing revision KA died within tenten years of surgery. Several patient and surgical factors, including PJI, were associated with the risk of mortality within ten years of primary and revision surgery. Cite this article: Bone Joint J 2022;104-B(1):45–52.


Author(s):  
Mamta Prajapat ◽  
Suniti Verma ◽  
R N Sehra ◽  
Jyoti Saini

Background: Cytology examines exfoliated cells, while colposcopy examines the changes that occur in the vascular structure of the cervix5. Patients with an abnormal pap smear result or patients with a suspicious-looking cervix even if they had a negative pap smear, should be evaluated by colposcopy and colposcopy directed biopsy. Methods: Interventional Prospective study conducted at Department of Obstetrics and Gynaecology, SMS Medical College & associated Hospitals, Jaipur. Results: In this study, among 15 IUCD users, 5 (33.33%) had bacterial vaginosis, 2 (13.33%) had trichomonas vaginalis and 1 (6.66%) were found candidal infection, 1 (6.66%) polymicrobial infection. Conclusion: The present study indicates that there is definite changes in the cervical architecture in IUCD users and the change is also dependent on the duration of use. A simple technique like cytology and colposcopy is highly useful in diagnosing these changes and combating them by early interference whenever necessary. The present study does not reveal any increased risk of cervicitis and dysplasia in IUCD users. We further recommend that a long term follow-up is required to rule out the possibility of any increased risk of dysplasia or carcinoma in-situ. Keywords: IUCD, Colposcopy, Dysplasia.


2013 ◽  
pp. 53-66
Author(s):  
Gulraj S. Matharu ◽  
Matthew P. Revell ◽  
Vaiyapuri Sumathi ◽  
Paul B. Pynsent ◽  
Peter A. Revell

Joints ◽  
2020 ◽  
Author(s):  
Christian Carulli ◽  
Giacomo Sani ◽  
Fabrizio Matassi ◽  
Roberto Civinini ◽  
Massimo Innocenti

Abstract Purrpose Metal-on-metal (MoM) total hip arthroplasty (THA) has been a subject of recent discussion and concern due to the early failures caused by local and systemic adverse reactions related to specific designs. The aim of this study is to analyze the outcomes and survival rates of a single brand of MoM implants implanted in a consecutive series of patients at a single institution. Methods Between 2007 and 2012, 116 (118 hips) patients were evaluated at a mean follow-up of 6.6 years after primary THA. The diagnosis leading to surgery was osteoarthritis (80 patients) and proximal femoral fracture (36 patients). A single design of THA was implanted. All patients were evaluated before surgery and postoperatively at 1, 3, 6, and 12 months by clinical scores and radiographic studies. The data analysis was made using Student's t-test. Results The minimum follow-up was of 4 years, with a mean follow-up of 6.6 years. Two aseptic loosenings of the acetabular component were recorded (one per group), which were not associated with local or systemic complications related to metal ion release. Both were revised by an isolated acetabular cup substitution with metal-on-polyethylene couplings. Nonprogressive radiolucency lines < 2 mm in zone 2 were observed in other six patients around the acetabular component without clinical manifestation (four in the arthritis group and two in the fracture group). Postoperative Harris Hip Score and SF-36 (36-Item Short Form Survey) score improved in both groups. Conclusion Despite several MoM implants showing early complications and failures, a specific MoM design may be associated with good clinical results at a mid- to long-term follow-up. Level of Evidence This is a therapeutic case series, Level 4 study.


Sign in / Sign up

Export Citation Format

Share Document