scholarly journals The Fragility of the Near-Hand Effect

2018 ◽  
Vol 4 (1) ◽  
Author(s):  
Jill A. Dosso ◽  
Alan Kingstone

Recent literature has demonstrated that hand position can affect visual processing, a set of phenomena termed Near Hand Effects (NHEs). Across four studies we looked for single-hand NHEs on a large screen when participants were asked to discriminate stimuli based on size, colour, and orientation (Study 1), to detect stimuli after a manipulation of hand shaping (Study 2), to detect stimuli after the introduction of a peripheral cue (Study 3), and finally to detect stimuli after a manipulation of screen orientation (Study 4). Each study failed to find a NHE. Further examination of the pooled data using a Bayesian analysis also failed to reveal positive evidence for faster responses or larger cueing effects near a hand. These findings suggest that at least some NHEs may be surprisingly fragile, which dovetails with the recent proposition that NHEs may not form a unitary set of phenomena (Gozli & Deng, 2018). The implication is that visual processing may be less sensitive to hand position across measurement techniques than previously thought, and points to a need for well-powered, methodologically rigorous studies on this topic in the future.

Author(s):  
Adolfo Meisel-Roca ◽  
Angela Granger

In this article, we present a review of the studies on the heights of children and teenagers in Colombia published since 1957. We focus on examining the geographic coverage, features of the population studied, height measurement techniques, authors’ profiles, and growth patterns in children. This relatively recent literature has been developed mainly by medical doctors who carried out rigorous measurements with highly specific time and space horizons. The first studies emphasized the differences among socioeconomic levels. Later, there was an interest in minority groups, such as indigenous people and Afro-descendants. Although most of the research lacked long-term vision, the overall balance shows that the country has been improving in anthropometric indicators over time, across territories, and in different socioeconomic groups.


2019 ◽  
Vol 5 (1) ◽  
Author(s):  
Tony Thomas ◽  
Meera Mary Sunny

Recent studies have demonstrated altered visual processing of stimuli in the proximal region of the hand. It has been challenging to characterize the range and nature of these processing differences. In our attempt to deconstruct the factors giving rise to the Hand-Proximity Effects (HPEs), we manipulated the organization of items in a visual search display. In two experiments, we observed the absence of HPE. Specifically, in Experiment 1, we presented the search display in only one half of the monitor (split diagonally), which could be either near or far from the hand placed on the corner of the monitor. The results of a Bayesian analysis showed that the search efficiency was not significantly different for neither ‘near’ nor ‘far’ condition when compared with the baseline condition in which the hand rested on the lap. In Experiment 2, the search display was arranged horizontally across the monitor. A Bayesian analysis showed that RTs did not vary depending on the proximity of the target to the hand as well as the baseline (lap) condition. The present results characterize features of the HPE that have not been reported previously and are in line with recent reports of the failure to replicate HPE under various circumstances.


2014 ◽  
Vol 14 (10) ◽  
pp. 1041-1041
Author(s):  
W. Bush ◽  
S. Vecera

1975 ◽  
Vol 26 ◽  
pp. 87-92
Author(s):  
P. L. Bender

AbstractFive important geodynamical quantities which are closely linked are: 1) motions of points on the Earth’s surface; 2)polar motion; 3) changes in UT1-UTC; 4) nutation; and 5) motion of the geocenter. For each of these we expect to achieve measurements in the near future which have an accuracy of 1 to 3 cm or 0.3 to 1 milliarcsec.From a metrological point of view, one can say simply: “Measure each quantity against whichever coordinate system you can make the most accurate measurements with respect to”. I believe that this statement should serve as a guiding principle for the recommendations of the colloquium. However, it also is important that the coordinate systems help to provide a clear separation between the different phenomena of interest, and correspond closely to the conceptual definitions in terms of which geophysicists think about the phenomena.In any discussion of angular motion in space, both a “body-fixed” system and a “space-fixed” system are used. Some relevant types of coordinate systems, reference directions, or reference points which have been considered are: 1) celestial systems based on optical star catalogs, distant galaxies, radio source catalogs, or the Moon and inner planets; 2) the Earth’s axis of rotation, which defines a line through the Earth as well as a celestial reference direction; 3) the geocenter; and 4) “quasi-Earth-fixed” coordinate systems.When a geophysicists discusses UT1 and polar motion, he usually is thinking of the angular motion of the main part of the mantle with respect to an inertial frame and to the direction of the spin axis. Since the velocities of relative motion in most of the mantle are expectd to be extremely small, even if “substantial” deep convection is occurring, the conceptual “quasi-Earth-fixed” reference frame seems well defined. Methods for realizing a close approximation to this frame fortunately exist. Hopefully, this colloquium will recommend procedures for establishing and maintaining such a system for use in geodynamics. Motion of points on the Earth’s surface and of the geocenter can be measured against such a system with the full accuracy of the new techniques.The situation with respect to celestial reference frames is different. The various measurement techniques give changes in the orientation of the Earth, relative to different systems, so that we would like to know the relative motions of the systems in order to compare the results. However, there does not appear to be a need for defining any new system. Subjective figures of merit for the various system dependon both the accuracy with which measurements can be made against them and the degree to which they can be related to inertial systems.The main coordinate system requirement related to the 5 geodynamic quantities discussed in this talk is thus for the establishment and maintenance of a “quasi-Earth-fixed” coordinate system which closely approximates the motion of the main part of the mantle. Changes in the orientation of this system with respect to the various celestial systems can be determined by both the new and the conventional techniques, provided that some knowledge of changes in the local vertical is available. Changes in the axis of rotation and in the geocenter with respect to this system also can be obtained, as well as measurements of nutation.


Author(s):  
D. E. Speliotis

The interaction of electron beams with a large variety of materials for information storage has been the subject of numerous proposals and studies in the recent literature. The materials range from photographic to thermoplastic and magnetic, and the interactions with the electron beam for writing and reading the information utilize the energy, or the current, or even the magnetic field associated with the electron beam.


Author(s):  
T. Schober

Nb, Ta and V are prototype substances for the study of the endothermic reactions of H with metals. Such metal-hydrogen reactions have gained increased importance due to the application of metal-hydrides in hydrogen- und heat storage devices. Electron microscopy and diffraction were demonstrated to be excellent methods in the study of hydride morphologies and structures (1). - Figures 1 and 2 show the NbH and TaH phase diagrams (2,3,4). EM techniques have contributed substantially to the elucidation of the structures and domain configurations of phases β, ζ and ε (1,4). Precision length measurement techniques of distances in reciprocal space (5) recently led to a detailed understanding of the distortions of the unit cells of phases ζ and ε (4). In the same work (4) the existence of the new phase η was shown. It is stable near -68 °C. The sequence of transitions is thus below 70 %.


Author(s):  
L. F. Allard ◽  
E. Völkl ◽  
T. A. Nolan

The illumination system of the cold field emission (CFE) Hitachi HF-2000 TEM operates with a single condenser lens in normal imaging mode, and with a second condenser lens excited to give the ultra-fine 1 nm probe for microanalysis. The electron gun provides a guaranteed high brightness of better than 7×l08 A/cm2/sr, more than twice the guaranteed brightness of Schottky emission guns. There have been several articles in the recent literature (e.g. refs.) which claim that the geometry of this illumination system yields a total current which is so low that when the beam is spread at low magnifications (say 10 kX), the operator must “keep his eyes glued to the binoculars” in order to see the image. It is also claimed that this illuminating system produces an isoplanatic patch (the area over which image character does not vary significantly) at high magnification which is so small that the instrument is ineffective for recording high resolution images.


2012 ◽  
Vol 17 (2) ◽  
pp. 69-75 ◽  
Author(s):  
Pamela A. Smith

In this article, I will review the available recent literature about the aging population with autism, a patient group that researchers know little about and a group that is experiencing a growing need for support from communication disorders professionals. Speech-language pathologists working with geriatric patients should become familiar with this issue, as the numbers of older patients with autism spectrum disorders is likely to increase. Our profession and our health care system must prepare to meet the challenge these patients and residents will present as they age.


1999 ◽  
Vol 4 (1) ◽  
pp. 6-7
Author(s):  
James J. Mangraviti

Abstract The accurate measurement of hip motion is critical when one rates impairments of this joint, makes an initial diagnosis, assesses progression over time, and evaluates treatment outcome. The hip permits all motions typical of a ball-and-socket joint. The hip sacrifices some motion but gains stability and strength. Figures 52 to 54 in AMA Guides to the Evaluation of Permanent Impairment (AMA Guides), Fourth Edition, illustrate techniques for measuring hip flexion, loss of extension, abduction, adduction, and external and internal rotation. Figure 53 in the AMA Guides, Fourth Edition, illustrates neutral, abducted, and adducted positions of the hip and proper alignment of the goniometer arms, and Figure 52 illustrates use of a goniometer to measure flexion of the right hip. In terms of impairment rating, hip extension (at least any beyond neutral) is irrelevant, and the AMA Guides contains no figures describing its measurement. Figure 54, Measuring Internal and External Hip Rotation, demonstrates proper positioning and measurement techniques for rotary movements of this joint. The difference between measured and actual hip rotation probably is minimal and is irrelevant for impairment rating. The normal internal rotation varies from 30° to 40°, and the external rotation ranges from 40° to 60°.


Sign in / Sign up

Export Citation Format

Share Document