3D Body Scanning Method for Close- Fitting Garments in Sport and Medical Applications

Author(s):  
Olga Troynikov ◽  
Elnaz Ashayeri
2021 ◽  
Vol 237 ◽  
pp. 01013
Author(s):  
Xue Zhang ◽  
Hongshu Jin

To improve the fitness of bottoms of individuals, this study is proposed to extract lumbar shape factors influencing the ratio of waist dart’s volumes of young females. A total of 27 measurement items including lumbar shapes and waist dart’s volumes were collected through overlapped graphics of lumbar feature sections obtained from 30 female college students aged 18 and 24via 3D body scanning method. Results of correlation analysis showed that the total waist dart’s volume was significantly correlated with the lateral lumbar bending level (ytc), and the ratio of each waist dart’s volume was significantly correlated with lumbar anteversion angle (β), lumbar anteverted amount (ytq) and buttock projected volume (ab) respectively with a correlation coefficient above r=0.7. Furthermore, a total of 2 factors with a characteristic value that was larger than 1 were extracted through principle component analysis, whose cumulative contribution rate reached 80.241%. Principle Component 1 represented factors of lumbar anteversion, which was related to the ratio of anterior/posterior waist dart’s volume; and Principle Component 2 represented the lateral lumbar shape characteristics affecting the total waist dart’s volume.


2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Eva Lindell ◽  
Hanna Tingsvik ◽  
Li Guo ◽  
Joel Peterson

Abstract Every year, approximately 3,000 people in Sweden undergo amputation of a body part. The use of a prosthesis can greatly improve the quality of life for these people. To improve the fit and comfort of a prosthesis, a sock is used as an interface between the prosthesis socket and the stump. A three-dimensional (3D) body scanner can be used to take measurements that are used to produce individualized socks that improve fit and comfort. The standardized method for taking measurements with a 3D body scanner often requires a standing position and hence a new scanning method is needed to improve the accessibility for 3D body scanning. This study aimed to create a scanning scenario and an algorithm for scanning amputation stumps for individualizing prosthesis socks for upper-body amputations. Vitronic VITUSSMART LC 3D Body Scanner was used in this study. The results show a seated position with arms slightly away from the body, scanned at 45° as the best. To measure the right upper arm and the left armpit, the best was to scan at a 315° angle. Paired t-tests showed no significant differences compared with the 3D body scanner of traditional manual measurements. The proposed method exhibited good relative reliability and potential to facilitate the customization of prosthetic socks for amputees.


Author(s):  
R. Levi-Setti ◽  
J.M. Chabala ◽  
Y.L. Wang

Finely focused beams extracted from liquid metal ion sources (LMIS) provide a wealth of secondary signals which can be exploited to create high resolution images by the scanning method. The images of scanning ion microscopy (SIM) encompass a variety of contrast mechanisms which we classify into two broad categories: a) Emission contrast and b) Analytical contrast.Emission contrast refers to those mechanisms inherent to the emission of secondaries by solids under ion bombardment. The contrast-carrying signals consist of ion-induced secondary electrons (ISE) and secondary ions (ISI). Both signals exhibit i) topographic emission contrast due to the existence of differential geometric emission and collection effects, ii) crystallographic emission contrast, due to primary ion channeling phenomena and differential oxidation of crystalline surfaces, iii) chemical emission or Z-contrast, related to the dependence of the secondary emission yields on the Z and surface chemical state of the target.


2020 ◽  
Vol 118 (1) ◽  
pp. 106
Author(s):  
Lei Zhang ◽  
Jianliang Zhang ◽  
Kexin Jiao ◽  
Guoli Jia ◽  
Jian Gong ◽  
...  

The three-dimensional (3D) model of erosion state of blast furnace (BF) hearth was obtained by using 3D laser scanning method. The thickness of refractory lining can be measured anywhere and the erosion curves were extracted both in the circumferential and height directions to analyze the erosion characteristics. The results show that the most eroded positions located below 20# tuyere with an elevation of 7700 mm and below 24#–25# tuyere with an elevation of 8100 mm, the residual thickness here is only 295 mm. In the circumferential directions, the serious eroded areas located between every two tapholes while the taphole areas were protected well by the bonding material. In the height directions, the severe erosion areas located between the elevation of 7600 mm to 8200 mm. According to the calculation, the minimum depth to ensure the deadman floats in the hearth is 2581 mm, corresponding to the elevation of 7619 mm. It can be considered that during the blast furnace production process, the deadman has been sinking to the bottom of BF hearth and the erosion areas gradually formed at the root of deadman.


1976 ◽  
Vol 15 (02) ◽  
pp. 69-74
Author(s):  
M. Goldberg ◽  
B. Doyon

This paper describes a general data base management package, devoted to medical applications. SARI is a user-oriented system, able to take into account applications very different by their nature, structure, size, operating procedures and general objectives, without any specific programming. It can be used in conversational mode by users with no previous knowledge of computers, such as physicians or medical clerks.As medical data are often personal data, the privacy problem is emphasized and a satisfactory solution implemented in SARI.The basic principles of the data base and program organization are described ; specific efforts have been made in order to increase compactness and to make maintenance easy.Several medical applications are now operational with SARI. The next steps will mainly consist in the implementation of highly sophisticated functions.


Sign in / Sign up

Export Citation Format

Share Document