A Review of Factors Influencing the Crack Tolerance of Titanium Alloys

Author(s):  
JL Shannon ◽  
WF Brown
2020 ◽  
Vol 38 (1) ◽  
pp. 25-47 ◽  
Author(s):  
Michael O. Bodunrin ◽  
Lesley H. Chown ◽  
Josias W. van der Merwe ◽  
Kenneth K. Alaneme ◽  
Christian Oganbule ◽  
...  

AbstractThis paper presents an overview of the corrosion behavior of titanium (Ti) alloys in both acidic and saline solutions. The solutions covered in this review are essentially the typical electrolytes encountered by Ti alloys when applied under service conditions. Although Ti alloys are generally known to be corrosion resistant, this review identifies strong reducing acids and fluoride-containing solutions as electrolytes that corrode Ti and its alloys. The pathways that the knowledge of the corrosion behavior of Ti alloys have followed from the 1950s to date are captured in this review. Based on this, the different factors influencing the corrosion behavior of Ti alloys are highlighted and the different research concepts for improving the corrosion resistance of Ti alloys in both solutions are discussed. The limitations of these research concepts are mentioned and the directions for future research are proposed.


Author(s):  
N. E. Paton ◽  
D. de Fontaine ◽  
J. C. Williams

The electron microscope has been used to study the diffusionless β → β + ω transformation occurring in certain titanium alloys at low temperatures. Evidence for such a transformation was obtained by Cometto et al by means of x-ray diffraction and resistivity measurements on a Ti-Nb alloy. The present work shows that this type of transformation can occur in several Ti alloys of suitable composition, and some of the details of the transformation are elucidated by means of direct observation in the electron microscope.Thin foils were examined in a Philips EM-300 electron microscope equipped with a uniaxial tilt, liquid nitrogen cooled, cold stage and a high resolution dark field device. Selected area electron diffraction was used to identify the phases present and the ω-phase was imaged in dark field by using a (101)ω reflection. Alloys were water quenched from 950°C, thinned, and mounted between copper grids to minimize temperature gradients in the foil.


Author(s):  
Shiro Fujishiro ◽  
Harold L. Gegel

Ordered-alpha titanium alloys having a DO19 type structure have good potential for high temperature (600°C) applications, due to the thermal stability of the ordered phase and the inherent resistance to recrystallization of these alloys. Five different Ti-Al-Ga alloys consisting of equal atomic percents of aluminum and gallium solute additions up to the stoichiometric composition, Ti3(Al, Ga), were used to study the growth kinetics of the ordered phase and the nature of its interface.The alloys were homogenized in the beta region in a vacuum of about 5×10-7 torr, furnace cooled; reheated in air to 50°C below the alpha transus for hot working. The alloys were subsequently acid cleaned, annealed in vacuo, and cold rolled to about. 050 inch prior to additional homogenization


Author(s):  
G. Das ◽  
R. E. Omlor

Fiber reinforced titanium alloys hold immense potential for applications in the aerospace industry. However, chemical reaction between the fibers and the titanium alloys at fabrication temperatures leads to the formation of brittle reaction products which limits their development. In the present study, coated SiC fibers have been used to evaluate the effects of surface coating on the reaction zone in the SiC/IMI829 system.IMI829 (Ti-5.5A1-3.5Sn-3.0Zr-0.3Mo-1Nb-0.3Si), a near alpha alloy, in the form of PREP powder (-35 mesh), was used a茸 the matrix. CVD grown AVCO SCS-6 SiC fibers were used as discontinuous reinforcements. These fibers of 142μm diameter contained an overlayer with high Si/C ratio on top of an amorphous carbon layer, the thickness of the coating being ∽ 1μm. SCS-6 fibers, broken into ∽ 2mm lengths, were mixed with IMI829 powder (representing < 0.1vol%) and the mixture was consolidated by HIP'ing at 871°C/0. 28GPa/4h.


Author(s):  
Julie A. Martini ◽  
Robert H. Doremus

Tracy and Doremus have demonstrated chemical bonding between bone and hydroxylapatite with transmission electron microscopy. Now researchers ponder how to improve upon this bond in turn improving the life expectancy and biocompatibility of implantable orthopedic devices.This report focuses on a study of the- chemical influences on the interfacial integrity and strength. Pure hydroxylapatite (HAP), magnesium doped HAP, strontium doped HAP, bioglass and medical grade titanium cylinders were implanted into the tibial cortices of New Zealand white rabbits. After 12 weeks, the implants were retrieved for a scanning electron microscopy study coupled with energy dispersive spectroscopy.Following sacrifice and careful retrieval, the samples were dehydrated through a graduated series starting with 50% ethanol and continuing through 60, 70, 80, 90, 95, and 100% ethanol over a period of two days. The samples were embedded in LR White. Again a graduated series was used with solutions of 50, 75 and 100% LR White diluted in ethanol.


Author(s):  
E. Sukedai ◽  
M. Shimoda ◽  
A. Fujita ◽  
H. Nishizawa ◽  
H. Hashimoto

ω-phase particles formed in β-titanium alloys (bcc structure) act important roles to their mechanical properties such as ductility and hardness. About the ductility, fine ω-phase particles in β–titanium alloys improve the ductility, because ω-phase crystals becomes nucleation sites of α-phase and it is well known that (β+α) duplex alloys have higher ductility. In the present study, the formation sites and the formation mechanism of ω-phase crystals due to external stress and aging are investigated using the conventional and high resolution electron microscopy.A β-titanium alloy (Til5Mo5Zr) was supplied by Kobe Steel Co., and a single crystal was prepared by a zone refining method. Plates with {110} surface were cut from the crystal and were pressured hydrostatically, and stressed by rolling and tensile testing. Specimens for aging with tensile stress were also prepared from Ti20Mo polycrystals. TEM specimens from these specimens were prepared by a twin-jet electron-polishing machine. A JEM 4000EX electron microscope operated at 400k V was used for taking dark field and HREM images.


1965 ◽  
Vol 8 (4) ◽  
pp. 323-347
Author(s):  
Robert Goldstein ◽  
Benjamin RosenblÜt

Electrodermal and electroencephalic responsivity to sound and to light was studied in 96 normal-hearing adults in three separate sessions. The subjects were subdivided into equal groups of white men, white women, colored men, and colored women. A 1 000 cps pure tone was the conditioned stimulus in two sessions and white light was used in a third session. Heat was the unconditioned stimulus in all sessions. Previously, an inverse relation had been found in white men between the prominence of alpha rhythm in the EEG and the ease with which electrodermal responses could be elicited. This relation did not hold true for white women. The main purpose of the present study was to answer the following questions: (1) are the previous findings on white subjects applicable to colored subjects? (2) are subjects who are most (or least) responsive electrophysiologically on one day equally responsive (or unresponsive) on another day? and (3) are subjects who are most (or least) responsive to sound equally responsive (or unresponsive) to light? In general, each question was answered affirmatively. Other factors influencing responsivity were also studied.


1950 ◽  
Vol 16 (1) ◽  
pp. 194-210 ◽  
Author(s):  
Frederick W. Hoffbauer ◽  
Jesse L. Bollman ◽  
John L. Grindlay

Sign in / Sign up

Export Citation Format

Share Document