Effects of Construction of a Diaphragm Wall Very Close to a Masonry Building

Author(s):  
SF Chan ◽  
TF Yap
2017 ◽  
Vol 55 (8) ◽  
pp. 668-673
Author(s):  
T. Kitamura ◽  
K. Tohkai ◽  
F. Kawagishi ◽  
M. Onishi

2012 ◽  
Vol 174-177 ◽  
pp. 2012-2015
Author(s):  
Xiao Long Zhou ◽  
Ying Min Li ◽  
Lin Bo Song ◽  
Qian Tan

There are two typical seismic damage characteristics to the masonry building with frame shear wall structure at first two stories, and the lateral stiffness ratio of the third storey to the second storey is one of the key factors mostly affecting the seismic performance of this kind of building. However, some factors are not considered sufficiently in current Chinese seismic codes. According to the theory of performance-based seismic design, the seismic performance of this kind of structure is analyzed in this paper by taking time-history analysis on models which with different storey stiffness ratios. The results show that when the lateral stiffness ratio controlled in a reasonable range, the upper masonry deformation can be ensured in a range of elastic roughly, and the bottom frame can be guaranteed to have sufficient deformation and energy dissipation capacity. Finally, according to the seismic performance characteristics of masonry building with frame shear wall structure at first two stories, especially the characteristics under strong earthquakes, a method of simplified calculation model for the upper masonry is discussed in this paper.


Author(s):  
A. Sandoli ◽  
G. P. Lignola ◽  
B. Calderoni ◽  
A. Prota

AbstractA hybrid seismic fragility model for territorial-scale seismic vulnerability assessment of masonry buildings is developed and presented in this paper. The method combines expert-judgment and mechanical approaches to derive typological fragility curves for Italian residential masonry building stock. The first classifies Italian masonry buildings in five different typological classes as function of age of construction, structural typology, and seismic behaviour and damaging of buildings observed following the most severe earthquakes occurred in Italy. The second, based on numerical analyses results conducted on building prototypes, provides all the parameters necessary for developing fragility functions. Peak-Ground Acceleration (PGA) at Ultimate Limit State attainable by each building’s class has been chosen as an Intensity Measure to represent fragility curves: three types of curve have been developed, each referred to mean, maximum and minimum value of PGAs defined for each building class. To represent the expected damage scenario for increasing earthquake intensities, a correlation between PGAs and Mercalli-Cancani-Sieber macroseismic intensity scale has been used and the corresponding fragility curves developed. Results show that the proposed building’s classes are representative of the Italian masonry building stock and that fragility curves are effective for predicting both seismic vulnerability and expected damage scenarios for seismic-prone areas. Finally, the fragility curves have been compared with empirical curves obtained through a macroseismic approach on Italian masonry buildings available in literature, underlining the differences between the methods.


Heritage ◽  
2021 ◽  
Vol 4 (2) ◽  
pp. 585-611
Author(s):  
Michele Betti ◽  
Valentina Bonora ◽  
Luciano Galano ◽  
Eugenio Pellis ◽  
Grazia Tucci ◽  
...  

This paper reports the knowledge process and the analyses performed to assess the seismic behavior of a heritage masonry building. The case study is a three-story masonry building that was the house of the Renaissance architect and painter Giorgio Vasari (the Vasari’s House museum). An interdisciplinary approach was adopted, following the Italian “Guidelines for the assessment and mitigation of the seismic risk of the cultural heritage”. This document proposes a methodology of investigation and analysis based on three evaluation levels (EL1, analysis at territorial level; EL2, local analysis and EL3, global analysis), according to an increasing level of knowledge on the building. A comprehensive knowledge process, composed by a 3D survey by Terrestrial Laser Scanning (TLS) and experimental in situ tests, allowed us to identify the basic structural geometry and to assess the value of mechanical parameters subsequently needed to perform a reliable structural assessment. The museum represents a typology of masonry building extremely diffused in the Italian territory, and the assessment of its seismic behavior was performed by investigating its global behavior through the EL1 and the EL3 analyses.


2018 ◽  
Vol 32 (5) ◽  
pp. 04018058 ◽  
Author(s):  
Alper Aldemir ◽  
Baris Binici ◽  
Erdem Canbay ◽  
Ahmet Yakut

2010 ◽  
Vol 452-453 ◽  
pp. 105-108 ◽  
Author(s):  
Hong Fu Chen ◽  
Bai Tao Sun

During Wenchuan Ms 8.0 earthquake, masonry buildings have suffered severely damaged and collapsed, causing heavy casualties and huge economic losses. In this paper, based on seismic site survey data, some new phenomena and characteristics of earthquake damage in comparison with the 1976 Tangshan earthquake, such as seismic damage of large space buildings, inclined or “X” shaped crack in wall between windows or spandrel wall, stair damage, falling of precast reinforced concrete slab and horizontal crack at the bottom of structure, are discussed in detail. Then, the impact factors of seismic capacity of masonry building in Wenchuan earthquake, including construction age, seismic fortification, bay size, floor (roof) form, layer number, thickness of bearing wall are analyzed, respectively; Finally, some recommendations on seismic design and reconstruction of masonry structure by the seismic design code are proposed.


Author(s):  
G. Castellazzi ◽  
B. Pantò ◽  
G. Occhipinti ◽  
D. A. Talledo ◽  
L. Berto ◽  
...  

AbstractThe paper presents the comparison of the results obtained on a masonry building by nonlinear static analysis using different software operating in the field of continuum and discrete-macroelement modeling. The structure is inspired by an actual building, the "P. Capuzi" school in Visso (Macerata, Italy), seriously damaged following the seismic events that affected Central Italy from August 2016 to January 2017. The activity described is part of a wider research program carried out by various units involved in the ReLUIS 2017/2108—Masonry Structures project and having as its object the analysis of benchmark structures for the evaluation of the reliability of software packages. The comparison of analysis was carried out in relation to: global parameters (concerning the dynamic properties, capacity curves and, equivalent bilinear curves), synthetic parameters of structural safety (such as, for example, the maximum acceleration compatible with the life safety limit state) and the response in terms of simulated damage. The results allow for some insights on the use of continuum and discrete-macroelement modeling, with respect to the dispersion of the results and on the potential repercussions in the professional field. This response was also analyzed considering different approaches for the application of loads.


Sign in / Sign up

Export Citation Format

Share Document