A Review of Phosphate Ester Fire Resistance Mechanisms and Their Relevance to Fluid Testing

2009 ◽  
pp. 102-102-8
Author(s):  
TA Marolewski ◽  
ED Weil
2012 ◽  
Vol 97 (11) ◽  
pp. 2154-2161 ◽  
Author(s):  
Blandine Friederich ◽  
Abdelghani Laachachi ◽  
Michel Ferriol ◽  
Marianne Cochez ◽  
Rodolphe Sonnier ◽  
...  

1974 ◽  
Author(s):  
W. C. Young ◽  
R. C. Elwell ◽  
R. B. McBride

Two phosphate ester base fire-resistant fluids were determined in laboratory testing to be superior or equivalent to the conventional petroleum base oils presently used to lubricate industrial gas turbines. This test program included tests of simulated performance, fluid stability, and fire resistance. Some differences were found between the two phosphate ester fluids although neither was judged superior to the other. Limited filed experience with these fluids has been satisfactory to date.


Polymers ◽  
2021 ◽  
Vol 13 (23) ◽  
pp. 4206
Author(s):  
Long Yan ◽  
Xinyu Tang ◽  
Xiaojiang Xie ◽  
Zhisheng Xu

Four kinds of polyethylene glycol borate (PEG-BA) with different molecular weights were grafted into cyclic phosphate ester (PEA) to obtain flexible phosphate esters (PPBs), and then applied in amino resin to obtain a series of transparent intumescent fire-retardant coatings. The comprehensive properties of the transparent coatings containing different molecular weights of PEG-BA were investigated by various analytical instruments. The transparency and mechanical analyses indicate that the presence of PEG-BA slightly decreases the optical transparency of the coatings but improves the flexibility and adhesion classification of the coatings. The results from fire protection and cone calorimeter tests show that low molecular weight of PEG-BA exerts a positive flame-retarded effect in the coatings, while high molecular weight of PEG800-BA behaves against flame-retarded effect. Thermogravimetric and char residue analyses show that the incorporation of low molecular weight of PEG-BA clearly increases the thermal stability and residual weight of the coatings and generates a more compact and stable intumescent char on the surface of the coatings, thus resulting in superior synergistic flame-retarded effect. In particular, MPPB1 coating containing PEG200-BA exerts the best flame-retarded effect and highest residual weight of 36.3% at 700 °C, which has 57.6% reduction in flame spread rate and 23.9% reduction in total heat release compared to those of MPPB0 without PEG-BA. Accelerated ageing test shows that low molecular weight of PEG-BA promotes to enhance the durability of structural stability and fire resistance of the coatings, while PEG800-BA with high molecular weight weakens the ageing resistance. In summary, the fire-resistant and anti-ageing efficiencies of PEG-BA in the coatings depend on its molecular weight, which present the order of PEG200-BA > PEG400-BA > PEG600-BA > PEG800-BA.


Materials ◽  
2019 ◽  
Vol 12 (23) ◽  
pp. 4003 ◽  
Author(s):  
Le ◽  
Tsai

Hybrid structures known as timber–steel composites (TSCs) have been extensively studied due to their potential use as alternative construction materials that can satisfy demands related to sustainability. In addition to load capacity, fire resistance is a major consideration regarding the extensive use of TSCs. In this study, 12 specimens were tested using a glulam timber material covering cold-formed steel at the center. Specifically, the TSCs were fabricated from two timber blocks and an I-shaped steel core assembled using dowels or glue as a major structure. In order to use additional timber as a fire protection layer to protect a major structure by its charcoal produced after being burned, an additional timber with 5 cm in thickness was used to cover the major structure. The 1-h fire testing of TSC following the ISO 834-1 standard was applied, in order to achieve the potential application for a 4-story timber building. The results showed that temperatures at the steel flange increased by more than 300 °C for the final 5 min in 10 out of the 12 TSC specimens, indicating that the fire protection provided by the timber structure was not sufficient. The charcoal layer surpassing the extra timber was originally set and entered the steel structure of the TSC, which was expected to retain its physical qualities after a fire. Methods for evaluating the charring properties, based on the conventional method for wood and the standard specification set by Eurocode 5, were used to assess the structural degradation of TSCs. The conventional assessments showed a divergence from the actual performance of TSCs. Such variations demonstrated the limitations of models for conventional wood in assessing the structure of a TSC. A realistic assessment was conducted to expand knowledge related to this composite under destructive processes and provide fire reference values for the practical implementation of TSCs.


Fruits ◽  
2009 ◽  
Vol 64 (5) ◽  
pp. 295-303 ◽  
Author(s):  
Hang Ye ◽  
Wen-jun Wang ◽  
Guo-jie Liu ◽  
Li-xin Zhu ◽  
Ke-gong Jia

JMS SKIMS ◽  
2020 ◽  
Vol 23 (1) ◽  
pp. 48-49
Author(s):  
Javaid Ahmad Bhat ◽  
Shariq Rashid Masoodi

Apropos to the article by Dr Bali, titled “Mupirocin resistance in clinical isolates of methicillin-sensitive and resistant Staphylococcus aureus in a tertiary care centre of North India” (1), the authors have raised important issue of emerging antimicrobial resistance (AMR). Antimicrobial resistance is an increasingly serious threat to global public health that requires action across all government sectors and society. As per WHO, AMR lurks the effective prevention and management of an ever-increasing spectrum of infections caused by bacteria, parasites, fungi and viruses. Novel resistance mechanisms are emerging and spreading globally, threatening the man’s ability to treat common infectious diseases.


Sign in / Sign up

Export Citation Format

Share Document