Determination of Carbon Monoxide in Blood by Gas Chromatography Using a Thermal Conductivity Detector

1986 ◽  
Vol 31 (1) ◽  
pp. 11867J ◽  
Author(s):  
Leo R. Goldbaum ◽  
Donald H. Chace ◽  
Nicholas T. Lappas
2008 ◽  
Vol 46 (5) ◽  
pp. 392-394 ◽  
Author(s):  
C. Bernardi ◽  
L. M. Chiesa ◽  
S. Soncin ◽  
E. Passero ◽  
P. A. Biondi

2015 ◽  
Vol 12 (24) ◽  
pp. 7-16
Author(s):  
Harry BUDIMAN ◽  
Oman ZUAS

High accurate result of carbon dioxide (CO2) measurement is of great importance since the result (data) is used as the foundation for decision making related to regulated monitoring program and law enforcement. In this study, therefore, method for measurement of high level of carbon dioxide (CO2) in nitrogen (N2) matrix using gas chromatography thermal conductivity detector (GC-TCD) was validated to achieve the optimum performance of the method. For this purposes, identity confirmation, selectivity, limit of detection (LoD), limit of quantitation (LoQ), repeatability, reproducibility, accuracy, and linearity of the method were evaluated. The result shows that the GC-TCD method has good precision in term of repeatability and reproducibility having values of 0.07 and 0.37%, respectively. No bias of the method can be found and an excellent linearity of the method was obtained in the range of 2 - 13.97% mol/mol. Thus, based on the result evaluation under given criteria of this study, it can be concluded that the GC-TCD method is reliable and suitable for determination of high level of CO2 in N2 matrix.


1981 ◽  
Vol 61 (3) ◽  
pp. 827-831 ◽  
Author(s):  
T. W. FENTON ◽  
MIRJANA FENTON ◽  
G. W. MATHISON

A gas chromatographic procedure for measuring water in fermented feeds was developed and evaluated. The method involves extracting the water with alcohol followed by the separation of the water and alcohol with a Porapak QS column in a gas chromatograph equipped with a thermal conductivity detector. Linear responses were obtained when the ratios of the peak area of water to alcohol were plotted against the weight ratios of water to alcohol (mg/g). The method has the advantage of being very fast, and is as accurate as a chemical method used for water determination.


1972 ◽  
Vol 55 (6) ◽  
pp. 1336-1338
Author(s):  
Brunetto Bazzi ◽  
Guglielmo Galluzzi ◽  
Luigi Abruzzese

Abstract A gas chromatographic method has been developed for the analysis of O,O-diethyl S-(N-isopropylcarbamoylmethyl) phosphorothiolothionate . The acaricide or a convenient amount of an acaricidal preparation is dissolved in xylene, together with malathion as an internal standard, and analyzed by gas chromatography, using a thermal conductivity detector. The precision (P = 0.05) of the method is ±1.5% of the concentration level.


Author(s):  
G.P. Morie ◽  
C.H. Sloan

AbstractA gas chromatographic method for the determination of carbon monoxide and carbon dioxide in cigarette smoke was developed. A column containing Porapak Q packing and a cryogenic temperature programmer which employed liquid nitrogen to cool the column to subambient temperatures was used. The separation of N


Sign in / Sign up

Export Citation Format

Share Document