scholarly journals Analysis of the Imaging Characteristics of the KB and KBA X-ray Microscopes at Non-coaxial Grazing Incidence

Open Physics ◽  
2018 ◽  
Vol 16 (1) ◽  
pp. 751-756
Author(s):  
Zhao Lingling ◽  
Jon Knepper

AbstractIn the last 20 years, requirements for x-ray lithography, space technology and ICF process diagnosis, the x-ray imaging technology has been developed. However, x-ray imaging turns out to be more difficult due to intense absorption of x-rays, and the refractive index of x band is slightly less than 1. Normal imaging method may not be suitable for x-ray band. At present, grazing reflective imaging and coded aperture imaging are commonly used for this band. This paper presents a detailed analysis of the imaging characteristics of single-mirror and double-mirror. Then the focal distance, field obliquity and aperture position of the mirrors of the KBA microscopes at grazing incidence are studied. The results show that the structure arrangement of the KBA microscope is rather reasonable, and can be considered as theoretical evidence in the design and manufacture of KBA microscopes.

1990 ◽  
Vol 115 ◽  
pp. 53-56
Author(s):  
B. Wargelin ◽  
S.M. Kahn ◽  
W. Craig ◽  
R. London

AbstractLaser plasmas are well-suited to studies of ionic photoabsorption because they can provide highly ionized, low temperature plasmas of high column density, as well as bright, compact continuum X-ray sources which can illuminate the plasma under study. In our experiment, continuum X-rays from a gold laser plasma are partially absorbed as they traverse a carbon plasma and are then dispersed by a grazing incidence reflection grating. An X-ray imaging camera records both the absorbed and unabsorbed spectra simultaneously for later computer analysis to determine the photoabsorption cross sections for each carbon ion species.


2010 ◽  
Vol 2010 ◽  
pp. 1-39 ◽  
Author(s):  
René Hudec

Most of grazing incidence (reflective) X-ray imaging systems used in astronomy and in other (laboratory) applications are based on the Wolter 1 (or modified) arrangement. But there were proposed also other designs and configurations, which are considered for future applications for both in laboratory and (finitely) in space. The Kirkpatrick-Baez (KB) lenses as well as various types of Lobster-Eye (LE) optics and MCP/Micropore optics serve as an example. Analogously to Wolter lenses, the X-rays are mostly reflected twice in these systems to create focal images. The KB systems have already found wide usage in laboratory and synchrotron, both application are reviewed and discussed in detail in this paper. While this paper focuses on future possible applications of non-Wolter grazing incidence systems in space and astronomy, we also discuss in detail applications in other areas of science, where (in contrary to astronomy) some of these systems have demonstrated their advantages.


Author(s):  
M.G. Baldini ◽  
S. Morinaga ◽  
D. Minasian ◽  
R. Feder ◽  
D. Sayre ◽  
...  

Contact X-ray imaging is presently developing as an important imaging technique in cell biology. Our recent studies on human platelets have demonstrated that the cytoskeleton of these cells contains photondense structures which can preferentially be imaged by soft X-ray imaging. Our present research has dealt with platelet activation, i.e., the complex phenomena which precede platelet appregation and are associated with profound changes in platelet cytoskeleton. Human platelets suspended in plasma were used. Whole cell mounts were fixed and dehydrated, then exposed to a stationary source of soft X-rays as previously described. Developed replicas and respective grids were studied by scanning electron microscopy (SEM).


Author(s):  
D. A. Carpenter ◽  
Ning Gao ◽  
G. J. Havrilla

A monolithic, polycapillary, x-ray optic was adapted to a laboratory-based x-ray microprobe to evaluate the potential of the optic for x-ray micro fluorescence analysis. The polycapillary was capable of collecting x-rays over a 6 degree angle from a point source and focusing them to a spot approximately 40 µm diameter. The high intensities expected from this capillary should be useful for determining and mapping minor to trace elements in materials. Fig. 1 shows a sketch of the capillary with important dimensions.The microprobe had previously been used with straight and with tapered monocapillaries. Alignment of the monocapillaries with the focal spot was accomplished by electromagnetically scanning the focal spot over the beveled anode. With the polycapillary it was also necessary to manually adjust the distance between the focal spot and the polycapillary.The focal distance and focal spot diameter of the polycapillary were determined from a series of edge scans.


2021 ◽  
Author(s):  
Julius Muchui Thambura ◽  
Jeanette G.E du Plessis ◽  
Cheryl M E McCrindle ◽  
Tanita Cronje

Abstract Introduction Anecdotal evidence suggests that medical professionals in trauma units are requesting additional regional images using conventional x-ray systems, even after trauma patients have undergone full-body Lodox scans. Patients are then exposed to additional radiation, additional waiting times and an increased medical bill. This study aimed at investigating the extent to which Lodox systems were used in trauma units (n=28) in South Africa. Method In this descriptive cross-sectional study, the researcher invited one radiographer from the 28 hospitals in South Africa that use Lodox systems. Radiographers who were most experienced in using the Lodox system completed an online questionnaire. Results Twenty (71.43% n=20) out of twenty-eight radiographers responded. Most hospitals (90%, n=18) were referring patients for additional conventional x-ray images. Radiographers indicated that conventional x-rays were requested for the chest (27.80%, 10/36), the abdomen (16.67%, 6/36), the spine (13.89%, 5/36) and the extremities and skull (19.44%, 7/36). Additionally, radiographers reported using Lodox to perform procedures and examinations usually performed on conventional x-ray systems when conventional x-ray systems were not operational. Conclusion Currently, it is not clear if the use of conventional x-ray imaging following Lodox is necessary, but the results suggest that the practice is commonplace, with healthcare workers in most hospitals (90%, n=18) requesting additional x-ray imaging. The researcher thus recommends that an imaging protocol for Lodox imaging systems should be developed to guide the referral of the patients for further imaging.


Author(s):  
Dipayan Das ◽  
KC Santosh ◽  
Umapada Pal

Abstract Since December 2019, the Coronavirus Disease (COVID-19) pandemic has caused world-wide turmoil in less than a couple of months, and the infection, caused by SARS-CoV-2, is spreading at an unprecedented rate. AI-driven tools are used to identify Coronavirus outbreaks as well as forecast their nature of spread, where imaging techniques are widely used, such as CT scans and chest X-rays (CXRs). In this paper, motivated by the fact that X-ray imaging systems are more prevalent and cheaper than CT scan systems, a deep learning-based Convolutional Neural Network (CNN) model, which we call Truncated Inception Net, is proposed to screen COVID-19 positive CXRs from other non-COVID and/or healthy cases. To validate our proposal, six different types of datasets were employed by taking the following CXRs: COVID-19 positive, Pneumonia positive, Tuberculosis positive, and healthy cases into account. The proposed model achieved an accuracy of 99.96% (AUC of 1.0) in classifying COVID- 19 positive cases from combined Pneumonia and healthy cases. Similarly, it achieved an accuracy of 99.92% (AUC of 0.99) in classifying COVID-19 positive cases from combined Pneumonia, Tuberculosis and healthy CXRs. To the best of our knowledge, as of now, the achieved results outperform the existing AI-driven tools for screening COVID-19 using CXRs.


2009 ◽  
Vol 24 (6) ◽  
pp. 792 ◽  
Author(s):  
Alex von Bohlen ◽  
Markus Krämer ◽  
Christian Sternemann ◽  
Michael Paulus

2007 ◽  
Vol 204 (8) ◽  
pp. 2734-2739 ◽  
Author(s):  
K. Mizuno ◽  
Y. Furuya ◽  
K. Hirano ◽  
H. Okamoto

2012 ◽  
Vol 2012 ◽  
pp. 1-13 ◽  
Author(s):  
A. Teymurazyan ◽  
G. Pang

A Monte Carlo simulation was used to study imaging and dosimetric characteristics of a novel design of megavoltage (MV) X-ray detectors for radiotherapy applications. The new design uses Cerenkov effect to convert X-ray energy absorbed in optical fibres into light for MV X-ray imaging. The proposed detector consists of a matrix of optical fibres aligned with the incident X rays and coupled to an active matrix flat-panel imager (AMFPI) for image readout. Properties, such as modulation transfer function, detection quantum efficiency (DQE), and energy response of the detector, were investigated. It has been shown that the proposed detector can have a zero-frequency DQE more than an order of magnitude higher than that of current electronic portal imaging device (EPID) systems and yet a spatial resolution comparable to that of video-based EPIDs. The proposed detector is also less sensitive to scattered X rays from patients than current EPIDs.