Zug/Druck-Wechselversuche mit konstanter Amplitude der wahren Verformung bei niedrigen Lastspielzahlen / Low-cycle fatigue tests under reversed tensionlcompression stresses with constant true-strain amplitude / Essais de fatigue en traction alternée aux amplitudes constantes de déformation réelle pour un petit nombre d‘alternances

1966 ◽  
Vol 8 (9) ◽  
pp. 321-324
Author(s):  
Istvan Havas
Metals ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 811
Author(s):  
Shuo Weng ◽  
Yuhui Huang ◽  
Mingliang Zhu ◽  
Fuzhen Xuan

The degradation of mechanical properties of materials is essentially related to microstructural changes under service loadings, while the inhomogeneous degradation behaviors along welded joints are not well understood. In the present work, microstructural evolution under low-cycle fatigue in base metal (BM) and weld metal (WM) of NiCrMoV steel welded joints were investigated by miniature tensile tests and microstructural observations. Results showed that both the yield strength and ultimate tensile strength of the BM and WM decreased after low-cycle fatigue tests, which were attributed to the reduction of dislocation density and formation of low-energy structures. However, the microstructural evolution mechanisms in BM and WM under the same cyclic loadings were different, i.e., the decrease of dislocation density in BM was attributed to the dislocation pile-ups along the grain boundaries, dislocation tangles around the carbides at the lower strain amplitudes (±0.3% or ±0.5%). Additionally, when the strain amplitude was ±8%, the dislocation density was further decreased by the formation of subgrains in BM. For WM, the dislocation density decreased with the increase of strain amplitude, which was mainly caused by the dislocation pile-ups along the grain boundaries and the formation of subgrains.


Author(s):  
Masayuki Kamaya ◽  
Masahiro Kawakubo

Internal cracks were observed on the fracture surface of Type 316 stainless steel specimens subjected to a low-cycle fatigue test, in which the strain amplitude was more than 1%. In some cases the specimens fractured due to these internal cracks. In this study, the reason and conditions for the internal crack initiation were examined. Fatigue experiments were conducted using Type 316 stainless steel. In order to enhance the internal crack initiation, the specimens were subjected to pre-damaging and surface cracks were removed before the start of the fatigue tests. It was shown that specimens fractured due to internal cracks when the strain amplitude of pre-damaging was more than 1% and hourglass-type specimens were used. The fatigue life was reduced largely due to the internal cracks and the magnitude of reduction was more significant for the smaller strain amplitude of the fatigue tests. Inclusions were observed at the origin of some internal cracks. It was deduced that the hourglass geometry of the specimen enhanced the internal crack initiation. Namely, the multi-axial field was one of the factors promoting the internal crack initiation.


2016 ◽  
Vol 250 ◽  
pp. 139-144
Author(s):  
Stanislaw Mrozinski

In this paper results of P91 cast steel after static and fatigue tests were presented. During the tests longitudinal and transverse strains of the specimen were measured. Basing on the results a comparative analysis of nominal stresses σn,true stresses σrz, nominal strain energy ΔWpl (n) and true strain energy ΔWpl (n) was carried out. It was stated that differences between determined paramters rise with increasing strain.


1992 ◽  
Vol 114 (4) ◽  
pp. 390-398 ◽  
Author(s):  
T. Bui-Quoc ◽  
R. Gomuc ◽  
A. Biron

Low-cycle fatigue tests on Ti 6-4 (Ti-6Al-4V) have been carried out at 260°C under strain-controlled conditions with constant strain amplitude and increasing multistep strain levels. The results of constant strain amplitude tests were used to establish the fatigue diagram whereas the multistep tests were examined to assess the cyclic stress-strain behavior in comparison with the conventional stress-strain curve. Most of the tests were carried out under zero-to-tension conditions in the intermediatecycle range (Nf ≃ 3 x 103 to 105 cycles). The effect of prior strain cycling on the tensile properties was also investigated. The experimental data is discussed together with theoretical evaluations. In addition, microstructural examinations of the rupture surfaces have been made to show evidence on the type of crack initiation sites and on the crack propagation modes at different strain levels.


Materials ◽  
2021 ◽  
Vol 14 (15) ◽  
pp. 4070
Author(s):  
Andrea Karen Persons ◽  
John E. Ball ◽  
Charles Freeman ◽  
David M. Macias ◽  
Chartrisa LaShan Simpson ◽  
...  

Standards for the fatigue testing of wearable sensing technologies are lacking. The majority of published fatigue tests for wearable sensors are performed on proof-of-concept stretch sensors fabricated from a variety of materials. Due to their flexibility and stretchability, polymers are often used in the fabrication of wearable sensors. Other materials, including textiles, carbon nanotubes, graphene, and conductive metals or inks, may be used in conjunction with polymers to fabricate wearable sensors. Depending on the combination of the materials used, the fatigue behaviors of wearable sensors can vary. Additionally, fatigue testing methodologies for the sensors also vary, with most tests focusing only on the low-cycle fatigue (LCF) regime, and few sensors are cycled until failure or runout are achieved. Fatigue life predictions of wearable sensors are also lacking. These issues make direct comparisons of wearable sensors difficult. To facilitate direct comparisons of wearable sensors and to move proof-of-concept sensors from “bench to bedside,” fatigue testing standards should be established. Further, both high-cycle fatigue (HCF) and failure data are needed to determine the appropriateness in the use, modification, development, and validation of fatigue life prediction models and to further the understanding of how cracks initiate and propagate in wearable sensing technologies.


2016 ◽  
Vol 853 ◽  
pp. 246-250 ◽  
Author(s):  
Tao Fang ◽  
Qian Hua Kan ◽  
Guo Zheng Kang ◽  
Wen Yi Yan

Experiments on U75V rail steel were carried out to investigate the cyclic feature, ratcheting behavior and low-cycle fatigue under both strain- and stress-controlled loadings at room temperature. It was found that U75V rail steel shows strain amplitude dependent cyclic softening feature, i.e., the responded stress amplitude under strain-controlled decreases with the increasing number of cycles and reaches a stable value after about 20th cycle. Ratcheting strain increases with an increasing stress amplitude and mean stress, except for stress ratio, and the ratcheting strain in failure also increases with an increasing stress amplitude, mean stress and stress ratio. The low-cycle fatigue lives under cyclic straining decrease linearly with an increasing strain amplitude, the fatigue lives under cyclic stressing decrease with an increasing mean stress except for zero mean stress, and decrease with an increasing stress amplitude. Ratcheting behavior with a high mean stress reduces fatigue life of rail steel by comparing fatigue lives under stress cycling with those under strain cycling. Research findings are helpful to evaluate fatigue life of U75V rail steel in the railways with passenger and freight traffic.


2021 ◽  
pp. 096739112098570
Author(s):  
Mohammad Azadi ◽  
Mohsen Alizadeh ◽  
Seyed Mohammad Jafari ◽  
Amin Farrokhabadi

In the present article, acoustic emission signals were utilized to predict the damage in polymer matrix composites, reinforced by carbon fibers, in the low-cycle fatigue regime. Displacement-controlled fatigue tests were performed on open-hole samples, under different conditions, at various displacement amplitudes of 5.5, 6.0, 6.5 and 7.0 mm and also under various displacement rates of 25, 50, 100 and 200 mm/min. After acquiring acoustic emission signals during cycles, two characteristic parameters were used, including the energy and the cumulative energy. Obtained results implied that the energy parameter of acoustic emission signals could be used only for the macroscopic damage, occurring at more than 65% of normalized fatigue cycles under different test conditions. However, the cumulative energy could properly predict both microscopic and macroscopic defects, at least two failure types, including matrix cracking at first cycles and the fiber breakage at last cycles. Besides, scanning electron microscopy images proved initially such claims under all loading conditions.


Author(s):  
Jean Alain Le Duff ◽  
Andre´ Lefranc¸ois ◽  
Jean Philippe Vernot

In February/March 2007, The NRC issued Regulatory Guide “RG1.207” and Argonne National Laboratory issued NUREG/CR-6909 that is now applicable in the US for evaluations of PWR environmental effects in fatigue analyses of new reactor components. In order to assess the conservativeness of the application of this NUREG report, Low Cycle Fatigue (LCF) tests were performed by AREVA NP on austenitic stainless steel specimens in a PWR environment. The selected material exhibits in air environment a fatigue behavior consistent with the ANL reference “air” mean curve, as published in NUREG/CR-6909. LCF tests in a PWR environment were performed at various strain amplitude levels (± 0.6% or ± 0.3%) for two loading conditions corresponding to a simple or to a complex strain rate history. The simple loading condition is a fully reverse triangle signal (for comparison purposes with tests performed by other laboratories with the same loading conditions) and the complex signal simulates the strain variation for an actual typical PWR thermal transient. In addition, two various surface finish conditions were tested: polished and ground. This paper presents the comparisons of penalty factors, as observed experimentally, with penalty factors evaluated using ANL formulations (considering the strain integral method for complex loading), and on the other, the comparison of the actual fatigue life of the specimen with the fatigue life predicted through the NUREG report application. For the two strain amplitudes of ± 0.6% and ± 0.3%, LCF tests results obtained on austenitic stainless steel specimens in PWR environment with triangle waveforms at constant low strain rates give “Fen” penalty factors close to those estimated using the ANL formulation (NUREG/6909). However, for the lower strain amplitude level and a triangle loading signal, the ANL formulation is pessimistic compared to the AREVA NP test results obtained for polished specimens. Finally, it was observed that constant amplitude LCF test results obtained on ground specimens under complex loading simulating an actual sequence of a cold and hot thermal shock exhibits lower combined environmental and surface finish effects when compared to the penalty factors estimated on the basis of the ANL formulations. It appears that the application of the NUREG/CR-6909 in conjunction with the Fen model proposed by ANL for austenitic stainless steel provides excessive margins, whereas the current ASME approach seems sufficient to cover significant environmental effects for representative loadings and surface finish conditions of reactor components.


2010 ◽  
Vol 638-642 ◽  
pp. 455-460 ◽  
Author(s):  
A. Rutecka ◽  
L. Dietrich ◽  
Zbigniew L. Kowalewski

The AlSi8Cu3 and AlSi7MgCu0.5 cast aluminium alloys of different composition and heat treatment were investigated to verify their applicability as cylinder heads in the car engines [1]. Creep tests under the step-increased stresses at different temperatures, and low cycle fatigue (LCF) tests for a range of strain amplitudes and temperatures were carried out. The results exhibit a significant influence of the heat treatment on the mechanical properties of the AlSi8Cu3 and AlSi7MgCu0.5. An interesting fact is that the properties strongly depend on the type of quenching. Lower creep resistance (higher strain rates) and lower stress response during fatigue tests were observed for the air quenched materials in comparison to those in the water quenched. Cyclic hardening/softening were also observed during the LCF tests due to the heat treatment applied. The mechanical properties determined during the tests can be used to identify new constitutive equations and to verify existing numerical models.