External Quality Assessment: an effective tool for Clinical Governance in Laboratory Medicine

Author(s):  
Laura Sciacovelli ◽  
Sandra Secchiero ◽  
Lorena Zardo ◽  
Martina Zaninotto ◽  
Mario Plebani

AbstractThe implementation of Clinical Governance will require a redefinition of duties and accountability as a prerequisite to develop and achieve an overall improvement in clinical care through a culture of assessment and monitoring of quality. External Quality Assessment Schemes (EQAS) are the main tool enabling laboratories to measure the quality of their results; they must carefully assess and monitor all elements contributing to the formulation of laboratory information (results, reference ranges/decisional levels, interpretative comments and diagnostic algorithms). There are different ways to design and manage a Scheme and EQAS coordinators are mainly responsible for its effectiveness. The present paper reports, as an example, some experiences of the Centre of Biomedical Research (CRB), which manages EQAS according to high quality specifications and laboratories' needs, that can reflect the Clinical Governance philosophy. Our findings show that EQAS are able to control all the above aspects and, if organisers are committed to fulfilling the responsibility and accountability principles, they will be of great value in quality assessment and in developing an External Quality Assurance Program (EQAP). This is an inter-laboratory comparison designed and conducted to assure the following: evaluation of participants' performance (by evaluating not only analytical performance, but also test interpretation, and advice for clinicians on laboratory requests and diagnosis); evaluation of method performance; and continuous education, training and help. The main aim of the activities of an EQAP in Laboratory Medicine is to sustain improvements in the quality of services provided by participating laboratories for the benefit of patients.

Author(s):  
James O. Westgard ◽  
Sten A. Westgard

AbstractThere is a need to assess the quality being achieved for laboratory examinations that are being utilized to support evidence-based clinical guidelines. Application of Six Sigma concepts and metrics can provide an objective assessment of the current analytical quality of different examination procedures.A “Sigma Proficiency Assessment Chart” can be constructed for data obtained from proficiency testing and external quality assessment surveys to evaluate the observed imprecision and bias of method subgroups and determine quality on the Sigma scale.Data for hemoglobin AAssessment of quality on the Sigma scale provides evidence of the analytical performance that is being achieved relative to requirements for intended use and should be useful for identifying and prioritizing improvements that are needed in the analytical quality of laboratory examinations. In spite of global and national standardization programs, bias is still a critical limitation of current HbA


2020 ◽  
Vol 30 (2) ◽  
pp. 278-286
Author(s):  
Agnieszka Ćwiklińska ◽  
Barbara Kortas-Stempak ◽  
Maciej Jankowski ◽  
Gabriela Bednarczuk ◽  
Aleksandra Fijałkowska ◽  
...  

Introduction: Urine particle analysis is an important diagnostic tool. The aim of this study was to evaluate the quality of urine leukocyte (WBC) and erythrocyte (RBC) counting results obtained with manual and automated methods in Polish laboratories participating in the international external quality assessment (EQA) programme. Materials and methods: 1400 WBC and RBC counting results were obtained from 183 laboratories in EQA surveys organised by Labquality (Helsinki, Finland) from 2017 to 2019. The between-laboratory coefficient of variation (CV), the percentage difference between the laboratories' results and target values (Q-score (%)), as well as modified Youden plots were analysed. Results: For automated method groups, the medians of inter-laboratory CVs varied from 14% to 33% for WBC counting and from 10% to 39% for RBC counting. For manual method groups, the medians of CV varied from 53% to 71% (WBC) and from 55% to 70% (RBC), and they were significantly higher, in comparison to CVs for most automated method groups (P < 0.001). The highest percentage of results outside the target limits (36%) and the highest range of Q-score (%) (from - 93% to 706%) were observed for laboratories which participated in the surveys for the first or second time. The percentage of deviating results and the ranges of Q-score decreased with an increased frequency of laboratories’ participation in the surveys. Conclusions: The quality of manual methods of urine WBC and RBC counting is unsatisfactory. There is an urgent need to take actions to improve laboratories’ performance and to increase harmonisation of the results.


1994 ◽  
Vol 9 (1) ◽  
pp. 48-52
Author(s):  
A. Piffanelli ◽  
M. Giganti ◽  
P. Colamussi ◽  
C. Cittanti ◽  
D. Pelizzola ◽  
...  

The use of tumor marker tests has increased progressively in the last decade concomitant with the advent of new monoclonal antibodies and their growing use in clinical oncology for various follow-up programs. External quality assessment (EQA) schemes widely adopted in clinical chemistry, have been extended in the last decade to immunoassays of hormones and tumor markers. EQA results can provide realistic information on the quality of the assays, performed under routine conditions. The goal of this article is to report the main results and discrepancies encountered so far in External Quality Assessment programs on tumor markers.


Sign in / Sign up

Export Citation Format

Share Document