Proposal for guidelines to establish common biological reference intervals in large geographical areas for biochemical quantities measured frequently in serum and plasma

Author(s):  
Pål Rustad ◽  
Peter Felding ◽  
Ari Lahti

AbstractA suggestion for a standard procedure to establish biological reference intervals for biochemical quantities by a multicenter approach is presented. This procedure was developed for and used in the Nordic Reference Interval Project 2000 (NORIP). This project established biological reference intervals for 25 frequently requested biochemical quantities through cooperation of 102 Nordic laboratories. Each laboratory performed collection of reference samples and measurement using their routine methods. The bias of each routine method was eliminated by use of common reference materials measured in each of the participating laboratories.

1990 ◽  
Vol 36 (2) ◽  
pp. 366-369 ◽  
Author(s):  
S M Marcovina ◽  
J L Adolphson ◽  
M Parlavecchia ◽  
J J Albers

Abstract A common accuracy-based standardization program is indispensable for establishing reference intervals for the clinical use of apolipoproteins. The development and distribution of reference materials and quality-control materials that do not exhibit matrix effects between methods is essential to the standardization process. We examined the suitability of lyophilized material as a common reference material for the measurement of apolipoproteins A-I and B. We determined values for apolipoproteins A-I and B in frozen and lyophilized serum pools, using different immunochemical approaches. We found little or no differences in apolipoprotein A-I values between frozen and lyophilized pools as determined by the different methods. In contrast, values for apolipoprotein B in lyophilized samples were consistently lower than those obtained for frozen samples. After adjusting for the effect of dilution due to reconstitution, the difference in the apolipoprotein B values for lyophilized as compared with frozen samples ranged from -26% to 4%, depending upon the assay method. Evidently, serum pools in lyophilized from are not a suitable matrix for reference materials for apolipoprotein B measurements but can be used for apolipoprotein A-I measurements.


Author(s):  
Ari Lahti

AbstractFour existing methods for partitioning biochemical reference data into subgroups are compared. Two of these, the method of Sinton et al. and that of Ichihara and Kawai, are based on a quotient of a difference between the subgroups and the reference interval for the combined distribution. The criterion of Sinton et al. appears rather stringent and could lead to recommendations to apply a common reference interval in many cases where establishment of group-specific reference intervals would be more useful. The method of Ichihara and Kawai is similar to that of Sinton et al., but their criterion, based on a quantity derived from between-group and within-group variances, seems to lead to inconsistent results when applied to some model cases. These two methods have the common weakness of using gross differences between subgroup distributions as an indicator of differences between their reference limits, while distributions with different means can actually have equal reference limits and those with equal means can have different reference limits. The idea of Harris and Boyd to require that the proportions of the subgroup distributions outside the common reference limits be kept reasonably close to the ideal value of 2.5% as a prerequisite for using common reference limits seems to have been a major improvement. The other two methods considered, that of Harris and Boyd and the “new method” follow this idea. The partitioning criteria of Harris and Boyd have previously been shown to provide a poor correlation to those proportions, however, and the weaknesses of their method are summarized in a list of five drawbacks. Different versions of the new method offer improvements to these drawbacks.


2002 ◽  
Vol 48 (11) ◽  
pp. 1987-1999 ◽  
Author(s):  
Ari Lahti ◽  
Per Hyltoft Petersen ◽  
James C Boyd

Abstract Background: The aims of this report were to examine how unequal subgroup prevalences in the source population may affect reference interval partitioning decisions and to develop generally applicable guidelines for partitioning gaussian-distributed data. Methods: We recently proposed a new model for partitioning reference intervals when the underlying data distribution is gaussian. This model is based on controlling the proportions of the subgroup distributions that fall outside each of the common reference limits, using the distances between the reference limits of the subgroup distributions as functions to these proportions. We examine the significance of the unequal prevalence effect for the partitioning problem and quantify it for distance partitioning criteria by deriving analytical expressions to express these criteria as a function of the ratio of prevalences. An application example, illustrating various aspects of the importance of the prevalence effect, is also presented. Results: Dramatic shrinkage of the critical distances between reference limits of the subgroups needed for partitioning was observed as the ratio of prevalences, the larger one divided by the smaller one, was increased from unity. Because of this shrinkage, the same critical distances are not valid for all ratios of prevalences, but specific critical distances should be used for each particular value of this ratio. Although proportion criteria used in determining the need for reference interval partitioning are not dependent on the prevalence effect, this effect should be accounted for when these criteria are being applied by adjusting the sample sizes of the subgroups to make them correspond to the ratio of prevalences. Conclusions: The prevalences of subgroups in the reference population should be known and observed in the calculations for every reference interval study, irrespective of whether distance or proportion criteria are being used to determine the need for reference interval partitioning. We present detailed methods to account for the prevalences when applying each of these types of criteria. Analytical expressions for the distance criteria, to be used when high precision is needed, and approximate distances, to be used in practical work, are derived. General guidelines for partitioning gaussian distributed data are presented. Following these guidelines and using the new model, we suggest that partitioning can be performed more reliably than with any of the earlier models because the new model not only offers an improved correspondence between the critical distances and the critical proportions, but also accounts for the prevalence effect.


Author(s):  
Volkher Scharnhorst ◽  
Joke Apperloo ◽  
Henk Baadenhuijsen ◽  
Huib L. Vader

AbstractStandardization of laboratory results allows for the use of common reference intervals and can be achieved via calibration of field methods with secondary reference materials. These harmonization materials should be commutable, i.e., they produce identical numerical results independent of assay principle or platform. This study assessed the commutability of a cryolyoprotectant-containing harmonization material, obtained from the Dutch Foundation for Quality Assessment in Clinical Laboratories, that is intended to harmonize measurements of enzyme activities within the Dutch project “Calibration 2000”. The catalytic concentrations of alkaline phosphatase, aspartate aminotransferase, alanine aminotransferase, lactate dehydrogenase, γ-glutamyltransferase and creatine kinase were analyzed in pooled patient sera and in the reference material in 14 laboratories. On liquid chemistry analyzers the harmonization material behaves like patient material. The enzyme activities measured in it fall on the regression lines calculated from activities measured in serum samples. For dry chemistry analyzers the activities of all enzymes measured in the harmonizator differ from the serum-based regression line. We show that this is due to the sucrose-containing cryolyoprotectant in the harmonization material. For each enzyme, correction factors were calculated that compensated for the bias and proved to be constant between reagent lots. Depending on the enzyme activity measured, application of these factors leads to 2- to 10-fold reduction of between-laboratory percentage coefficient of variation. Thus, additives to (potential) reference materials may alter their matrix in a way that interferes with analysis on certain test systems. The bias caused may be quantifiable and correctable. Establishment of correction factors leads to analytical uncertainties and costs. Therefore, matrix-based materials without additives should be selected as reference materials.


Author(s):  
N Jassam ◽  
A Luvai ◽  
D Narayanan ◽  
D Turnock ◽  
G Lee ◽  
...  

Background Harmonization of reference intervals for analytes that have a sound calibration and metrological traceability is a widely recommended practice. The UK Pathology Harmony has recently harmonized reference intervals for calcium and albumin. In this study, we have determined the reference intervals for calcium and albumin on the UK’s most commonly used analytical platforms. Method A prospective reference population of healthy individuals was recruited according to the IFCC CRIDL criteria. A second indirect population was collected from 14 primary care setting and measured in laboratories using various analytical platforms and methods (Roche, Abbott, Beckman and Siemens analytical platforms). Results In total, 299 subjects were recruited; the central 95th centile values for calcium for three out of four analytical platforms were in a close agreement with UK Pathology Harmony reference intervals of 2.2–2.6 mmol/L. Reference intervals of BCG methods from both cohorts and irrespective of analytical platforms were higher for both lower and upper reference limits than those for BCP. In comparison, the indirect study showed an age-related variation. The younger population reference intervals varied by up to 5.7% at the lower reference limit and up to 12% at the upper reference limit compared with Pathology Harmony reference intervals, and the older population showed a variation of up to 14% at both limits. Conclusion While calcium reference intervals can be a subject for harmonization, albumin reference intervals studied showed large variation which is unsupportive of embracing a common reference interval for albumin.


2008 ◽  
Vol 54 (2) ◽  
pp. 356-365 ◽  
Author(s):  
Kiyoshi Ichihara ◽  
Yoshihisa Itoh ◽  
Christopher W K Lam ◽  
Priscilla M K Poon ◽  
Jeong-Ho Kim ◽  
...  

Abstract Background: In a previous study to determine the feasibility of common reference intervals in Asia, we found significant differences among populations from 6 cities. In this study, we attempted to define the sources of these differences. Methods: We enrolled 580 healthy volunteers (279 men, 301 women, 20–62 years old), after a selection process that was based on the Clinical and Laboratory Standards Institute guidelines, and used a lifestyle questionnaire. All sera were obtained at a basal state and frozen at −80 °C until the collective assay was done. We measured 21 basic chemical analytes and 10 serum proteins. Results: We used 3-level nested ANOVA to separate the variation (SD) into between-city (SD-city), between-sex (SD-sex), between-age (SD-age), and between-individual (SD-indiv) components. SD-indiv corresponds to one-quarter of the “pure” reference interval obtained after removing variations due to city, sex, and age. The SD-sex to SD-indiv ratio was >0.8 for creatinine, urate, retinol-binding protein, and transthyretin. We observed high SD-city to SD-indiv ratios, ranging from 0.4 to 0.7, for 11 analytes including lactate dehydrogenase (LDH), electrolytes, IgG, and complement components and SD-age to SD-indiv ratios >0.4 for LDH, alkaline phosphatase, and total cholesterol. Multiple regression analysis demonstrated several other relevant sources of variation, including body mass index, alcohol consumption, and cigarette smoking, although their contributions were generally smaller than those for sex, region, or age. Conclusion: We observed unacceptably large regional differences in measured values of some analytes even after adjustment for age, sex, and lifestyle variables. Genetic and environmental factors may account for the residual differences.


Author(s):  
O E Okosieme ◽  
Medha Agrawal ◽  
Danyal Usman ◽  
Carol Evans

Background: Gestational TSH and FT4 reference intervals may differ according to assay method but the extent of variation is unclear and has not been systematically evaluated. We conducted a systematic review of published studies on TSH and FT4 reference intervals in pregnancy. Our aim was to quantify method-related differences in gestation reference intervals, across four commonly used assay methods, Abbott, Beckman, Roche, and Siemens. Methods: We searched the literature for relevant studies, published between January 2000 and December 2020, in healthy pregnant women without thyroid antibodies or disease. For each study, we extracted trimester-specific reference intervals (2.5–97.5 percentiles) for TSH and FT4 as well as the manufacturer provided reference interval for the corresponding non-pregnant population. Results: TSH reference intervals showed a wide range of study-to-study differences with upper limits ranging from 2.33 to 8.30 mU/L. FT4 lower limits ranged from 4.40–13.93 pmol/L, with consistently lower reference intervals observed with the Beckman method. Differences between non-pregnant and first trimester reference intervals were highly variable, and for most studies the TSH upper limit in the first trimester could not be predicted or extrapolated from non-pregnant values. Conclusions: Our study confirms significant intra and inter-method disparities in gestational thyroid hormone reference intervals. The relationship between pregnant and non-pregnant values is inconsistent and does not support the existing practice in some laboratories of extrapolating gestation references from non-pregnant values. Laboratories should invest in deriving method-specific gestation reference intervals for their population.


2021 ◽  
Author(s):  
K Aaron Geno ◽  
Matthew S Reed ◽  
Mark A Cervinski ◽  
Robert D Nerenz

Abstract Introduction Automated free thyroxine (FT4) immunoassays are widely available, but professional guidelines discourage their use in pregnant women due to theoretical under-recoveries attributed to increased thyroid hormone binding capacity and instead advocate the use of total T4 (TT4) or free thyroxine index (FTI). The impact of this recommendation on the classification of thyroid status in apparently euthyroid pregnant patients was evaluated. Methods After excluding specimens with thyroid autoantibody concentrations above reference limits, thyroid-stimulating hormone (TSH), FT4, TT4, and T-uptake were measured on the Roche Cobas® platform in remnant clinical specimens from at least 147 nonpregnant women of childbearing age and pregnant women at each trimester. Split-sample comparisons of FT4 as measured by the Cobas and equilibrium dialysis were performed. Results FT4 decreased with advancing gestational age by both immunoassay and equilibrium dialysis. TSH declined during the first trimester, remained constant in the second, and increased throughout the third, peaking just before delivery. Interpretation of TT4 concentrations using 1.5-times the nonpregnant reference interval classified 13.6% of first trimester specimens below the lower reference limit despite TSH concentrations within trimester-specific reference intervals. Five FTI results from 480 pregnant individuals (about 1.0%) fell outside the manufacturer’s reference interval. Conclusions Indirect FT4 immunoassay results interpreted in the context of trimester-specific reference intervals provide a practical and viable alternative to TT4 or FTI. Declining FT4 and increasing TSH concentrations near term suggest that declining FT4 is not an analytical artifact but represents a true physiological change in preparation for labor and delivery.