scholarly journals Multi objective Flower Pollination Algorithm for solving capacitor placement in radial distribution system using data structure load flow analysis

2016 ◽  
Vol 65 (2) ◽  
pp. 203-220 ◽  
Author(s):  
V. Tamilselvan ◽  
T. Jayabarathi

Abstract The radial distribution system is a rugged system, it is also the most commonly used system, which suffers by loss and low voltage at the end bus. This loss can be reduced by the use of a capacitor in the system, which injects reactive current and also improves the voltage magnitude in the buses. The real power loss in the distribution line is the I2R loss which depends on the current and resistance. The connection of the capacitor in the bus reduces the reactive current and losses. The loss reduction is equal to the increase in generation, necessary for the electric power provided by firms. For consumers, the quality of power supply depends on the voltage magnitude level, which is also considered and hence the objective of the problem becomes the multi objective of loss minimization and the minimization of voltage deviation. In this paper, the optimal location and size of the capacitor is found using a new computational intelligent algorithm called Flower Pollination Algorithm (FPA). To calculate the power flow and losses in the system, novel data structure load flow is introduced. In this, each bus is considered as a node with bus associated data. Links between the nodes are distribution lines and their own resistance and reactance. To validate the developed FPA solutions standard test cases, IEEE 33 and IEEE 69 radial distribution systems are considered.

Author(s):  
S. Bhongade ◽  
Sachin Arya

The work presented in this paper is carried out with the objective of identifying the optimal location and size (Kvar ratings) of shunt capacitors to be placed in radial distribution system, to have overall economy considering the saving due to energy loss minimization. To achieve this objective, a two stage methodology is adopted in this paper. In the first stage, the base case load flow of uncompensated distribution system is carried out. On the basis of base case load flow solution, Nominal voltage magnitudes and Loss Sensitivity Factors are calculated and the weak buses are selected for capacitor placement.In the second stage, Particle Swarm Optimization (PSO) algorithm is used to identify the size of the capacitors to be placed at the selected buses for minimizing the power loss. The developed algorithm is tested for 10-bus, 34-bus and 85-bus Radial Distribution Systems. The results show that there has been an enhancement in voltage profile and reduction in power loss thus resulting in much annual saving.


2018 ◽  
Vol 27 (3) ◽  
pp. 377-391
Author(s):  
Vipin Kumar ◽  
Shubham Swapnil ◽  
V. R. Singh

Abstract This paper presents a fast and efficient method for load flow analysis of radial distribution networks. Here, an adaptive algorithm is proposed to analyze the load flow problem of distribution systems. An adaptive algorithm is the combination of backward/forward (BW/FW) sweep and cuckoo search (CS) algorithms. In the proposed method, the optimum load flow analysis of the radial distribution system is attained, while optimizing the voltage and current computation of the BW/FW sweep algorithm. Now, by the CS, the output voltage of the BW/FW sweep algorithm is compared with the standard voltage and optimized. From the optimized voltage and current, load flow parameters like power loss and real and reactive power flow are assessed. The proposed method is implemented using the MATLAB platform and tested into the IEEE 33 bus radial distribution system. The effectiveness of the proposed technique is determined by comparing with the BW/FW algorithm and genetic algorithm-based BW/FW algorithm.


Author(s):  
Sayed Mir Shah Danish ◽  
Mikaeel Ahmadi ◽  
Atsushi Yona ◽  
Tomonobu Senjyu ◽  
Narayanan Krishna ◽  
...  

AbstractThe optimal size and location of the compensator in the distribution system play a significant role in minimizing the energy loss and the cost of reactive power compensation. This article introduces an efficient heuristic-based approach to assign static shunt capacitors along radial distribution networks using multi-objective optimization method. A new objective function different from literature is adapted to enhance the overall system voltage stability index, minimize power loss, and to achieve maximum net yearly savings. However, the capacitor sizes are assumed as discrete known variables, which are to be placed on the buses such that it reduces the losses of the distribution system to a minimum. Load sensitive factor (LSF) has been used to predict the most effective buses as the best place for installing compensator devices. IEEE 34-bus and 118-bus test distribution systems are utilized to validate and demonstrate the applicability of the proposed method. The simulation results obtained are compared with previous methods reported in the literature and found to be encouraging.


Sign in / Sign up

Export Citation Format

Share Document