Simulating High Rayleigh Number Natural Convection in High Aspect Ratio Horizontal Rectangular Enclosures Using Code Saturne Platform

Author(s):  
Ajaz Bashir Janjua ◽  
Fahad Sarfraz Butt ◽  
Abdul Waheed Badar ◽  
Abdullah Zafar
2004 ◽  
Vol 3 (2) ◽  
pp. 100
Author(s):  
T. Dias Jr. ◽  
L. F. Milanez

In this work, the laminar natural convection in high aspect ratio three-dimensional enclosures has been numerically studied. The enclosures studied here were heated with uniform heat flux on a vertical wall and cooled at constant temperature on the opposite wall. The remaining walls were considered adiabatic. Fluid properties were assumed constant except for the density change with temperature on the buoyancy term. The governing equations were solved using the finite volumes method and the dimensionless form of these equations has the Prandtl number and the modified Rayleigh number as parameters. The influences of the Rayleigh number and of the cavity aspect ratio on the Nusselt number, for a Prandtl number of 0.7, were analyzed. Results were obtained for values of the modified Rayleigh number up to 106 and for aspect ratios ranging from 1 to 20. The results were compared with two-dimensional results available in the literature and the variation of the average Nusselt number with the parameters studied were discussed.


2004 ◽  
Vol 3 (2) ◽  
Author(s):  
T. Dias Jr. ◽  
L. F. Milanez

In this work, the laminar natural convection in high aspect ratio three-dimensional enclosures has been numerically studied. The enclosures studied here were heated with uniform heat flux on a vertical wall and cooled at constant temperature on the opposite wall. The remaining walls were considered adiabatic. Fluid properties were assumed constant except for the density change with temperature on the buoyancy term. The governing equations were solved using the finite volumes method and the dimensionless form of these equations has the Prandtl number and the modified Rayleigh number as parameters. The influences of the Rayleigh number and of the cavity aspect ratio on the Nusselt number, for a Prandtl number of 0.7, were analyzed. Results were obtained for values of the modified Rayleigh number up to 106 and for aspect ratios ranging from 1 to 20. The results were compared with two-dimensional results available in the literature and the variation of the average Nusselt number with the parameters studied were discussed.


2019 ◽  
Vol 20 (1) ◽  
pp. 229-244
Author(s):  
Mehdi Ahmadi ◽  
Seyed Ali Agha Mirjalily ◽  
Seyed Amir Abbas Oloomi

ABSTRACT: This study is conducted to investigate turbulent natural convection flow in an enclosure with thermal sources using the low-Reynolds number (LRN) k-? model. This enclosure has a cold source with temperature Tc and a hot source with temperature Th as thermal sources, other walls of the enclosure are adiabatic. The aim of this study is to predict the effect of change in Rayleigh number, repositioning of cold and hot sources, and thermal sources aspect ratio on the flow field, temperature, and rate of heat transfer. To achieve this aim, the equations of continuity, momentum, energy, turbulent kinetic energy, and kinetic energy dissipation are employed in the case of 2D turbulence with constant thermo-physical properties except the density in the buoyancy term (Boussinesq approximation). To numerically solve these equations, the finite volume method and SIMPLE algorithm are used. According to the modeling results, the most optimal temperature distribution in the enclosure is seen when the hot source is below the cold source. With decreasing distance between hot and cold sources, heat transfer rate increases. The maximal heat transfer rate is derived via study of the heating sources aspect ratio. In constant positions of cold and hot sources on a wall, the heat transfer rate increases with increasing Rayleigh number (Ra=109-1011). ABSTAK: Kajian ini dijalankan bagi mengkaji perubahan semula jadi aliran perolakan dalam tempat tertutup dengan sumber haba menggunakan model k-? nombor Reynolds-rendah (LRN). Bekas tertutup ini mempunyai dua sumber haba iaitu sumber sejuk dengan suhu Tc dan sumber panas dengan suhu Th, manakala dinding lain bekas ini adalah adiabatik. Tujuan kajian ini adalah bagi mengesan perubahan nombor Rayleigh, mengubah sumber sejuk dan panas dan nisbah sumber haba kepada kawasan aliran, suhu dan halaju perubahan haba. Bagi mencapai tujuan tersebut, persamaan sambungan, momentum, tenaga, tenaga kinetik perolakan, dan pengurangan tenaga kinetik telah dilaksanakan dalam kes perolakan 2D dengan sifat fizikal-haba berterusan (malar) kecuali isipadu terma keapungan (anggaran Boussinesq). Bagi menyelesaikan persamaan ini secara berangka, kaedah isipadu terhad dan algorithma MUDAH telah digunakan. Berdasarkan keputusan model, suhu distribusi optimal dalam bekas tertutup dilihat apabila sumber panas adalah kurang daripada sumber sejuk. Dengan pengurangan jarak antara sumber panas dan sejuk, kadar pertukaran haba meningkat. Kadar pertukaran haba maksima telah diperoleh melalui kajian nisbah  aspek sumber pemanasan. Kadar pertukaran haba bertambah dengan bertambahnya nombor Rayleigh  (Ra=109-1011), pada posisi tetap sumber sejuk dan panas pada dinding bekas.


2019 ◽  
Vol 29 (10) ◽  
pp. 3659-3684 ◽  
Author(s):  
Rasul Mohebbi ◽  
Mohsen Izadi ◽  
Nor Azwadi Che Sidik ◽  
Gholamhassan Najafi

Purpose This paper aims to study the natural convection of a nanofluid inside a cavity which contains obstacles using lattice Boltzmann method (LBM). The results have focused mainly on various parameters such as number and aspect ratio of roughness elements and different nanoparticle volume fraction. The isotherms and streamlines are presented to describe the hydrodynamics and thermal behaviors of the nanofluid flow throughout the enclosure. Design/methodology/approach The methodology of this paper consists of mathematical model, statement of the problem, nanofluid thermophysical properties, lattice Boltzmann method, LBM for fluid flow, LBM for heat transfer, numerical strategy, boundary conditions, Nusselt (Nu) number calculation, code validation and grid independence. Findings Natural convection heat transfers of a nanofluid inside cavities with and without rough elements have been studied. Lattice Boltzmann technique has been used as numerical approach. The results showed that at higher Rayleigh number (Ra = 106), there are denser streamlines near the left (source) and right wall (sink) which results in better cooling and enhances convective heat rejection to the heat sink. After a distinctive aspect ratio of rough elements (A = 0.1), change in streamline pattern which arises from increasing of aspect ratio does not have an important effect on isotherms. Results indicate that for lower Rayleigh number (Ra = 103), no variation in average Nu is observed with increasing in number of roughness, while for higher one (Ra = 106) average Nu decreases from N = 0 (smooth cavity) up to N = 4 and then remains constant (N = 6). Originality/value Currently, no argumentative and comprehensive extraction can be concluded without fully understanding the role of different arrangement of roughness. Some geometrical parameters such as aspect ratio, number and position of rough elements have been considered. Also, the effect of nanoparticle concentration was studied at different Ra number. Briefly, using LBM, this paper aims to investigate the natural convection of a nanofluid flow on the thermal and hydrodynamics parameters in the presence of rough element with various arrangements.


2015 ◽  
Vol 19 (5) ◽  
pp. 1621-1632 ◽  
Author(s):  
Mahmoud Salari ◽  
Ali Mohammadtabar ◽  
Mohammad Mohammadtabar

In this paper, entropy generation induced by natural convection of cu-water nanofluid in rectangular cavities with different circular corners and different aspect-ratios were numerically investigated. The governing equations were solved using a finite volume approach and the SIMPLE algorithm was used to couple the pressure and velocity fields. The results showed that the total entropy generation increased with the increase of Rayleigh number, irreversibility coefficient, aspect ratio or solid volume fraction while it decreased with the increase of the corner radius. It should be noted that the best way for minimizing entropy generation is decreasing Rayleigh number. This is the first priority for minimizing entropy generation. The other parameters such as radius, volume fraction, etc are placed on the second priority. However, Bejan number had an inverse trend compared with total entropy generation. As an exception, Bejan number and total entropy number had the same trend whenever solid volume fraction increased. Moreover, Nusselt number increased as Rayleigh number, solid volume fraction or aspect ratio increased whereas it decreases with the increase of corner radius.


1989 ◽  
Vol 111 (4) ◽  
pp. 916-925 ◽  
Author(s):  
V. Prasad ◽  
A. Chui

A numerical study is performed on natural convection inside a cylindrical enclosure filled with a volumetrically heated, saturated porous medium for the case when the vertical wall is isothermal and the horizontal walls are either adiabatic or isothermally cooled. When the horizontal walls are insulated, the flow in the cavity is unicellular and the temperature field in upper layers is highly stratified. However, if the top wall is cooled, there may exist a multicellular flow and an unstable thermal stratification in the upper region of the cylinder. Under the influence of weak convection, the maximum temperature in the cavity can be considerably higher than that predicted for pure conduction. The local heat flux on the bounding walls is generally a strong function of the Rayleigh number, the aspect ratio, and the wall boundary conditions. The heat removal on the cold upper surface decreases with the aspect ratio, thereby increasing the Nusselt number on the vertical wall. The effect of Rayleigh number is, however, not straightforward. Several correlations are presented for the maximum cavity temperature and the overall Nusselt number.


Author(s):  
Yu-Peng Hu ◽  
You-Rong Li ◽  
Chun-Mei Wu

In this paper, a series of numerical simulations for natural convection of water near its maximum-density around a cylinder inside a concentric triangular enclosure were conducted using finite volume method. The effects of the density inversion parameter, the aspect ratio, the Rayleigh number and the inclination angle on natural convection were discussed. Furthermore, the flow and temperature fields, the local and average Nusselt numbers at different parameters were obtained and analyzed. The results show that the flow pattern and temperature distribution are unique for various density inversion parameters and inclination angles. The density inversion parameter, the aspect ratio, the Rayleigh number all have significant effects on the overall heat transfer rates, except for the inclination angle. The present results can also contribute further information on the natural convection of non-Boussinesq fluid in enclosures.


Author(s):  
Patrick H. Oosthuizen

A numerical study of free convective flow in a vertical joined three enclosure arrangement has been undertaken. In this arrangement, a vertical heated wall kept at a uniform high temperature is contained in a high aspect ratio rectangular side enclosure. This enclosure is joined to a second high aspect ratio rectangular side enclosure which has the same height as the first side enclosure, the two enclosures being separated by a vertical impermeable dividing wall which offers no resistance to heat transfer. The second side enclosure is joined to a larger square enclosure, the vertical dividing wall between these two enclosures also being impermeable and offering no resistance to heat transfer. The vertical wall of the square main flow enclosure opposite to the dividing wall is maintained at a uniform lower temperature. There is a uniform rate of heat generation in the dividing wall between the inner side enclosure and the main enclosure. The situation considered is an approximate model of a double-paned window exposed to a hot outside environment and covered by a plane blind which in turn is exposed to cooled room. In some such cases there can be significant heat generation in the blind due to the absorbtion of solar energy, this being modeled by the heat generation in the one dividing wall. The flow has been assumed to be laminar and two-dimensional and results have been obtained for a Prandtl number of 0.7. The effects of Rayleigh number, dimensionless width of the side enclosures and dimensionless heat generation rate in the blind on the Nusselt number have been investigated. The results show that for a fixed Rayleigh number and for a given dimensionless first (i.e., outer) side enclosure width, there is a minimum in the Nusselt number variation with the dimensionless width of the second side enclosure. An approximate solution for the Nusselt number variation with the dimensionless width of the second side enclosure for small values of this dimensionless width has also been derived.