scholarly journals Chest Pain Associated with Moderator Band Pacing

2014 ◽  
Vol 41 (5) ◽  
pp. 551-553 ◽  
Author(s):  
Anil K. Goli ◽  
Karoly Kaszala ◽  
Mohammed N. Osman ◽  
John Lucke ◽  
Roger Carrillo

A 65-year-old man was evaluated for chronic chest pain that had been present for 8 years after placement of a dual-chamber implantable cardioverter-defibrillator to treat inducible ventricular tachycardia. Previous coronary angiography had revealed nonobstructive coronary artery disease and a left ventricular ejection fraction of 0.45 to 0.50, consistent with mild idiopathic nonischemic cardiomyopathy. Evaluation with chest radiography and transthoracic echocardiography showed the implantable cardioverter-defibrillator lead to be embedded within the right ventricle at the moderator band, which had mild calcification. Treatment included extraction of the dual-coil lead and placement of a new single-coil right ventricular lead at the mid septum. The patient had complete relief of symptoms after the procedure. This case shows that chest pain can be associated with the placement of a right ventricular implantable cardioverter-defibrillator lead in the moderator band and that symptomatic relief can occur after percutaneous lead extraction and the implantation of a new right ventricular lead to the mid septal region.

2010 ◽  
Vol 138 (3-4) ◽  
pp. 236-239
Author(s):  
Ruzica Jurcevic ◽  
Lazar Angelkov ◽  
Dejan Vukajlovic ◽  
Velibor Ristic ◽  
Milosav Tomovic ◽  
...  

Introduction. We described the first case of oversensing due to electric shock in Serbia, in a 54-year-old man who had implantable cardioverter-defibrillator (ICD). Case Outline. In July 2002, the patient had acute anteroseptal myocardial infarction and ventricular fibrillation (VF) which was terminated with six defibrillation shocks of 360 J. Coronary angiography revealed 30% stenosis of circumflex artery, the left anterior descending coronary artery was recanalized and the right coronary artery was without stenosis. Left ventricular ejection fraction was 20%. In December 2003, an electrophysiology study was performed and ventricular tachycardia (VT) was induced and terminated with 200 J defibrillation shock. Single chamber ICD Medtronic Gem III VR was implanted in January 2004 and defibrillation threshold was 12 J. The patient was followed up during three years every three months and there were no VT/VF episodes and VT/VF therapies. In December 2007, the patient experienced electric shock through the fork while he was making barbecue on the electric grill. ICD recognized this event in VF zone (oversensing) and delivered defibrillation shock of 18 J. The electrogram of the episode showed ventricular sensing - intrinsic sinus rhythm with electric shock potentials which were misidentified as VF. After charge time of 3.16 seconds, ICD delivered defibrillation shock and sinus rhythm was still present. Conclusion. Oversensing of ICD has different aetiology and the most common cause is supraventricular tachyarrhythmia.


Author(s):  

Dilated cardiomyopathy (DCM) is a disease characterised as left ventricular (LV) or biventricular dilatation with impaired systolic function. Regardless of underlying cause patients with DCM have a propensity to ventricular arrhythmias and sudden cardiac death. Implantable Cardioverter Defibrillator (ICD) implantation for these patients results in significant reduction of sudden cardiac death [1-3]. ICD devices may be limited by right ventricle (RV) sensing dysfunction with low RV sensing amplitude. We present a clinical case of patient with DCM, implanted ICD and low R wave sensing on RV lead.


2021 ◽  
Vol 10 (4) ◽  
Author(s):  
Andrea Demarchi ◽  
Stefano Cornara ◽  
Antonio Sanzo ◽  
Simone Savastano ◽  
Barbara Petracci ◽  
...  

Background When implantable cardioverter defibrillator (ICD) battery is depleted most patients undergo generator replacement (GR) even in the absence of persistent ICD indication. The aim of this study was to assess the incidence of ventricular arrhythmias and the overall prognosis of patients with and without persistent ICD indication undergoing GR. Predictors of 1‐year mortality were also analyzed. Methods and Results Patients with structural heart disease implanted with primary prevention ICD undergoing GR were included. Patients were stratified based on the presence/absence of persistent ICD indication (left ventricular ejection fraction ≤35% at the time of GR and/or history of appropriate ICD therapies during the first generator's life). The study included 371 patients (82% male, 40% with ischemic heart disease). One third of patients (n=121) no longer met ICD indication at the time of GR. During a median follow‐up of 34 months after GR patients without persistent ICD indication showed a significantly lower incidence of appropriate ICD shocks (1.9% versus 16.2%, P <0.001) and ICD therapies. 1‐year mortality was also significantly lower in patients without persistent ICD indication (1% versus 8.3%, P =0.009). At multivariable analysis permanent atrial fibrillation, chronic advanced renal impairment, age >80, and persistent ICD indication were found to be significant predictors of 1‐year mortality. Conclusions Patients without persistent ICD indication at the time of GR show a low incidence of appropriate ICD therapies after GR. Persistent ICD indication, atrial fibrillation, advanced chronic renal disease, and age >80 are significant predictors of 1‐year mortality. Our findings enlighten the need of performing a comprehensive clinical reevaluation of ICD patients at the time of GR.


Heart Rhythm ◽  
2014 ◽  
Vol 11 (12) ◽  
pp. 2196-2201 ◽  
Author(s):  
Luca Segreti ◽  
Andrea Di Cori ◽  
Ezio Soldati ◽  
Giulio Zucchelli ◽  
Stefano Viani ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document