Seismic Design Criteria for Slab-Column Connections

2007 ◽  
Vol 104 (4) ◽  
2021 ◽  
Vol 885 ◽  
pp. 127-132
Author(s):  
Sarmad Shakeel ◽  
Alessia Campiche

The current edition of Eurocode 8 does not cover the design of the Cold-Formed steel (CFS) building structures under the seismic design condition. As part of the revision process of Euro-code 8 to reflect the outcomes of extensive research carried out in the past decade, University of Naples “Federico II” is involved in the validation of existing seismic design criteria and development of new rules for the design of CFS systems. In particular, different types of Lateral Force Resisting System (LFRS) are analyzed that can be listed in the second generation of Eurocode 8. The investigated LFRS’s include CFS strap braced walls and CFS shear walls with steel sheets, wood, or gypsum sheathing. This paper provides the background information on the research works and the reference design standards, already being used in some parts of the world, which formed the basis of design criteria for these LFRS systems. The design criteria for the LFRS-s common to CFS buildings would include rules necessary for ensuring the dissipative behavior, appropriate values of the behavior factor, guidelines to predict the design strength, geometrical and mechanical limitations.


1977 ◽  
Vol 103 (11) ◽  
pp. 2288-2288
Author(s):  
Otto W. Steinhardt ◽  
Felix Y. Mao

1999 ◽  
Vol 192 (2-3) ◽  
pp. 117-135 ◽  
Author(s):  
Robert P. Kennedy

2004 ◽  
Vol 126 (1) ◽  
pp. 9-17 ◽  
Author(s):  
Makoto Inaba ◽  
Masatoshi Ikeda ◽  
Nobuyuki Shimizu

After the Great Hyogoken-nanbu Earthquake (1995), the Seismic Design Code for High-Pressure Gas Facilities of Japan was amended. This amended code requires two-step seismic assessments, that is, the evaluation of the Level 1 Required Seismic Performance for Level 1 earthquakes and that of the Level 2 Required Seismic Performance for Level 2 earthquakes. Seismic design of piping systems is newly included within the scope of the code. For Level 2 earthquakes, possible ground displacement due to liquefaction is taken into account. The evaluation method of the Level 1 Required Seismic Performance is specified in the amended code and that of the Level 2 Required Seismic Performance is proposed in the guideline. The evaluation of the former is based on elastic design and that of the latter on elastoplastic design. The propriety of the design criteria of piping systems with respect to ground displacement was confirmed by large deformation tests. In this paper, seismic design criteria of piping systems in the amended code and the evaluation method of the Level 2 Required Seismic Performance proposed in the guideline are introduced, and the results of the large deformation tests are reported.


2017 ◽  
Vol 11 (1) ◽  
pp. 420-433 ◽  
Author(s):  
David Cassiano ◽  
Carlos Rebelo ◽  
Luís Simoes da Silva

Nowadays, many buildings with steel Moment Resisting Frames (MRF) are built in seismic zones when seismic codes are at its early stages of development, and as such, these structures are often designed solely to resist lateral wind loads without providing an overall ductile mechanism. On the other hand, current seismic design criteria based on hierarchy of resistance allow enhancing the structural ductility and controlling the structural plastic behaviour. Therefore, seismic design criteria might also be beneficial to improve the structural robustness. In order to investigate this issue for steel MRF, a parametric study based on pushdown analysis and on the Energy Balance Method is described and discussed in the present paper. With this regard, the following cases are examined: (i) MRF not designed for seismic actions and (ii) MRF designed for seismic actions. The investigated parameters are (i) the number of storeys, (ii) the interstorey height, (iii) the span length, (iv) the building plan layout and (v) the column loss scenario. Results show that the low-rise and long span structures are the most prone to progressive collapse and that the elements in the directly affected zone of the wind designed 8 storey structures respond in the elastic range. Structures designed according to the capacity design principles were found to be less robust than wind designed structures that are characterized by strong beams and weak columns. The number of elements above the removed column and size of beam cross section were found to be key parameters in arresting progressive collapse.


2014 ◽  
Vol 18 (5) ◽  
pp. 231-240
Author(s):  
Hyeong Yeol Seo ◽  
Kwang Soon Park ◽  
Ick Hyun Kim ◽  
Dong Soo Kim