Sequence development to improve image quality for T2- and diffusion weighted imaging at 7T

2021 ◽  
Author(s):  
◽  
Shahrokh Abbasi-rad
2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Jianxing Qiu ◽  
Jing Liu ◽  
Zhongxu Bi ◽  
Xiaowei Sun ◽  
Xin Wang ◽  
...  

Abstract Purpose To compare integrated slice-specific dynamic shimming (iShim) diffusion weighted imaging (DWI) and single-shot echo-planar imaging (SS-EPI) DWI in image quality and pathological characterization of rectal cancer. Materials and methods A total of 193 consecutive rectal tumor patients were enrolled for retrospective analysis. Among them, 101 patients underwent iShim-DWI (b = 0, 800, and 1600 s/mm2) and 92 patients underwent SS-EPI-DWI (b = 0, and 1000 s/mm2). Qualitative analyses of both DWI techniques was performed by two independent readers; including adequate fat suppression, the presence of artifacts and image quality. Quantitative analysis was performed by calculating standard deviation (SD) of the gluteus maximus, signal intensity (SI) of lesion and residual normal rectal wall, apparent diffusion coefficient (ADC) values (generated by b values of 0, 800 and 1600 s/mm2 for iShim-DWI, and by b values of 0 and 1000 s/mm2 for SS-EPI-DWI) and image quality parameters, such as signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of primary rectal tumor. For the primary rectal cancer, two pathological groups were divided according to pathological results: Group 1 (well-differentiated) and Group 2 (poorly differentiated). Statistical analyses were performed with p < 0.05 as significant difference. Results Compared with SS-EPI-DWI, significantly higher scores of image quality were obtained in iShim-DWI cases (P < 0.001). The SDbackground was significantly reduced on b = 1600 s/mm2 images and ADC maps of iShim-DWI. Both SNR and CNR of b = 800 s/mm2 and b = 1600 s/mm2 images in iShim-DWI were higher than those of b = 1000 s/mm2 images in SS-EPI-DWI. In primary rectal cancer of iShim-DWI cohort, SIlesion was significantly higher than SIrectum in both b = 800 and 1600 s/mm2 images. ADC values were significantly lower in Group 2 (0.732 ± 0.08) × 10− 3 mm2/s) than those in Group 1 ((0.912 ± 0.21) × 10− 3 mm2/s). ROC analyses showed significance of ADC values and SIlesion between the two groups. Conclusion iShim-DWI with b values of 0, 800 and 1600 s/mm2 is a promising technique of high image quality in rectal tumor imaging, and has potential ability to differentiate rectal cancer from normal wall and predicting pathological characterization.


2021 ◽  
pp. 1-8
Author(s):  
Haimei Cao ◽  
Xiang Xiao ◽  
Jun Hua ◽  
Guanglong Huang ◽  
Wenle He ◽  
...  

Objectives: The present study aimed to study whether combined inflow-based vascular-space-occupancy (iVASO) MR imaging (MRI) and diffusion-weighted imaging (DWI) improve the diagnostic accuracy in the preoperative grading of gliomas. Methods: Fifty-one patients with histopathologically confirmed diffuse gliomas underwent preoperative structural MRI, iVASO, and DWI. We performed 2 qualitative consensus reviews: (1) structural MR images alone and (2) structural MR images with iVASO and DWI. Relative arteriolar cerebral blood volume (rCBVa) and minimum apparent diffusion coefficient (mADC) were compared between low-grade and high-grade gliomas. Receiver operating characteristic (ROC) curve analysis was performed to compare the tumor grading efficiency of rCBVa, mADC, and the combination of the two parameters. Results: Two observers diagnosed accurate tumor grade in 40 of 51 (78.4%) patients in the first review and in 46 of 51 (90.2%) in the second review. Both rCBVa and mADC showed significant differences between low-grade and high-grade gliomas. ROC analysis gave a threshold value of 1.52 for rCBVa and 0.85 × 10−3 mm2/s for mADC to provide a sensitivity and specificity of 88.0 and 81.2% and 100.0 and 68.7%, respectively. The area under the ROC curve (AUC) was 0.87 and 0.85 for rCBVa and mADC, respectively. The combination of rCBVa and mADC values increased the AUC to 0.92. Conclusion: The combined application of iVASO and DWI may improve the diagnostic accuracy of glioma grading.


2021 ◽  
Vol 10 (2) ◽  
pp. 205846012199473
Author(s):  
Takeshi Yoshizako ◽  
Rika Yoshida ◽  
Hiroya Asou ◽  
Megumi Nakamura ◽  
Hajime Kitagaki

Background Echo-planar imaging (EPI)-diffusion-weighted imaging (DWI) may take unclear image affected by susceptibility, geometric distortions and chemical shift artifacts. Purpose To compare the image quality and usefulness of EPI-DWI and turbo spin echo (TSE)-DWI in female patients who required imaging of the pelvis. Material and Methods All 57 patients were examined with a 3.0-T MR scanner. Both TSE- and EPI-DWI were performed with b values of 0 and 1000 s/mm2. We compared geometric distortion, the contrast ratio (CR) of the myometrium to the muscle and the apparent diffusion coefficient (ADC) values for the myometrium and lesion. Two radiologists scored the TSE- and EPI-DWI of each patient for qualitative evaluation. Results The mean percent distortion was significantly smaller with TSE- than EPI-DWI ( p = 0.00). The CR was significantly higher with TSE- than EPI-DWI ( p = 0.003). There was a significant difference in the ADC value for the uterus and lesions between the EPI- and TSE-DWI ( p < 0.05). Finally, the ADC values of cancer were significantly different from those for the uterus and benign with both the two sequences ( p < 0.05). The scores for ghosting artifacts were higher with TSE- than EPI-DWI ( p = 0.019). But there were no significant differences between TSE- and EPI-DWI with regard to image contrast and overall image quality. Conclusion TSE-DWI on the female pelvis by 3T MRI produces less distortion and higher CR than EPI-DWI, but there is no difference in contrast and image quality.


2017 ◽  
Vol 21 (1) ◽  
Author(s):  
Zeynep Cetiner-Alpay ◽  
Fatma Kulali ◽  
Aslihan Semiz-Oysu ◽  
Yasar Bukte ◽  
Kamil Ozdil

Background: Although endoscopic retrograde cholangiopancreatography (ERCP) is accepted as the gold standard, there is a place for magnetic resonance cholangiopancreatography (MRCP) and diffusion-weighted imaging (DWI) in the diagnosis of obstructive biliary disorders.Aim: To compare the findings of MRCP with ERCP in patients with obstructive biliary disorders and to investigate the diagnostic efficacy of MRCP combined with DWI.Study design: Retrospective, analytic, cross-sectional study.Methods: The MRCP images of 126 patients who underwent both MRCP and ERCP owing to biliary obstruction were reviewed. Nine patients were excluded because of incomplete diagnostic workup or a long period (>3 months) between MRCP and ERCP. Ninety-two patients underwent DWI, which was also evaluated. The sensitivity, specificity and accuracy of MRCP and DWI were analysed.Results: The sensitivity, specificity and accuracy of MRCP according to ERCP results as the gold standard was 97%, 71% and 93% for assessment of biliary dilatation; 100%, 94.7% and 97.5% for the diagnosis of choledocholithiasis; 93.7%, 100% and 99% for the identification of benign strictures; 100%, 100% and 100% for the diagnosis of malignant tumours; and 100%, 100% and 100% for the detection of complicated hydatid cysts; respectively. The sensitivity and specificity of DWI for the diagnosis of malignant tumour was 100%. In the detection of choledocholithiasis, the sensitivity and specificity of DWI was 70.8% and 100%.Conclusions: MRCP is an alternative, non-invasive, diagnostic modality, comparable with ERCP for the evaluation of pancreaticobiliary diseases. DWI can be helpful for diagnosis of choledocholithiasis and tumours.


2016 ◽  
Vol 89 (1059) ◽  
pp. 20150911 ◽  
Author(s):  
Ying Yuan ◽  
Weiqing Tang ◽  
Mengda Jiang ◽  
Xiaofeng Tao

Sign in / Sign up

Export Citation Format

Share Document