Polarization Stabilized Optical Fiber Sensor with High Time Resolution Based on Optical Pulse Correlation and FRR

2006 ◽  
Author(s):  
Hongbin Song ◽  
Toshinori Suzuki ◽  
Koji Nonaka ◽  
Tatsutoshi Shioda ◽  
Takashi Kurokawa
1994 ◽  
Vol 144 ◽  
pp. 431-434
Author(s):  
M. Minarovjech ◽  
M. Rybanský

AbstractThis paper deals with a possibility to use the ground-based method of observation in order to solve basic problems connected with the solar corona research. Namely:1.heating of the solar corona2.course of the global cycle in the corona3.rotation of the solar corona and development of active regions.There is stressed a possibility of high-time resolution of the coronal line photometer at Lomnický Peak coronal station, and use of the latter to obtain crucial observations.


2010 ◽  
Vol 180 (4) ◽  
pp. 424 ◽  
Author(s):  
G.M. Beskin ◽  
S.V. Karpov ◽  
S.F. Bondar ◽  
V.L. Plokhotnichenko ◽  
A. Guarnieri ◽  
...  

2018 ◽  
Vol 56 (1) ◽  
pp. 94-99
Author(s):  
N. Sogabe ◽  
S. Nakaue ◽  
K. Chikiri ◽  
M. Hayakawa

2019 ◽  
Vol 5 (0) ◽  
pp. 19-00095-19-00095
Author(s):  
Shogo FUJIMOTO ◽  
Suguru UEMURA ◽  
Nobuyuki IMANISHI ◽  
Shuichiro HIRAI

Symmetry ◽  
2021 ◽  
Vol 13 (7) ◽  
pp. 1166
Author(s):  
Bin Liu ◽  
Jianping He ◽  
Shihai Zhang ◽  
Yinping Zhang ◽  
Jianan Yu ◽  
...  

Brillouin frequency shift (BFS) of distributed optical fiber sensor is extracted from the Brillouin gain spectrum (BGS), which is often characterized by Lorenz type. However, in the case of complex stress and optical fiber self damage, the BGS will deviate from Lorenz type and be asymmetric, which leads to the extraction error of BFS. In order to enhance the extraction accuracy of BFS, the Lorenz local single peak fitting algorithm was developed to fit the Brillouin gain spectrum curve, which can make the BSG symmetrical with respect to the Brillouin center frequency shift. One temperature test of a fiber-reinforced polymer (FRP) packaged sensor whose BSG curve is asymmetric was conducted to verify the idea. The results show that the local region curve of BSG processed by the developed algorithm has good symmetry, and the temperature measurement accuracy obtained by the developed algorithm is higher than that directly measured by demodulation equipment. Comparison with the reference temperature, the relative measurement error measured by the developed algorithm and BOTDA are within 4% and 8%, respectively.


Sign in / Sign up

Export Citation Format

Share Document