scholarly journals Characterization of spectral-domain OCT with autocorrelation interference response for axial resolution performance

2018 ◽  
Vol 26 (6) ◽  
pp. 7253 ◽  
Author(s):  
Sucbei Moon ◽  
Yueqiao Qu ◽  
Zhongping Chen
2009 ◽  
Vol 40 (1) ◽  
pp. 71-74 ◽  
Author(s):  
Muneeswar Gupta Nittala ◽  
Gella Laxmi ◽  
Rajiv Raman ◽  
Padmaja Kumari Rani ◽  
Arun Bhargava ◽  
...  

2020 ◽  
Vol 2020 ◽  
pp. 1-6
Author(s):  
Lishuang Liu ◽  
Jun Xie ◽  
Linbo Liu ◽  
Si Chen

Ultrahigh-resolution optical coherence tomography provides an axial resolution of 1-2 μm for resolving cellular structures of biological tissues critical for the diagnosis of diseases. However, it requires a relatively large spectral bandwidth which is not supported by the key components of the imaging system. We propose a novel spectral-domain OCT design, termed interferometer-in-spectrometer, which is able to compensate the bandwidth limitations of the grating and the line scan sensor by spectral shaping without compromising the signal intensity and adding the system cost. The advantage of axial resolution and ranging depth over the standard design is experimentally validated using the standard testing method and fresh swine cornea ex vivo. Moreover, opportunities that opened up by this new scheme for improving the performances of spectral-domain OCT are also discussed.


2016 ◽  
Vol 2016 ◽  
pp. 1-9 ◽  
Author(s):  
Pierre-Maxime Lévêque ◽  
Pierre Zéboulon ◽  
Emmanuelle Brasnu ◽  
Christophe Baudouin ◽  
Antoine Labbé

Purpose. To detect changes in optic nerve head (ONH) vascularization in glaucoma patients using spectral-domain OCT angiography (OCT-A).Material and Method. Fifty glaucoma patients and 30 normal subjects were evaluated with OCT-A (AngioVue®, Optovue). The total ONH vessel density and temporal disc vessel density were measured. Clinical data, visual field (VF) parameters, and spectral-domain OCT evaluation (RNFL: retinal nerve fiber layer thickness, GCC: ganglion cell complex thickness, and rim area) were recorded for glaucoma patients. Correlations among total and temporal ONH vessel density and structural and VF parameters were analyzed.Results. In the glaucoma group, total and temporal ONH vessel density were reduced by 24.7% (0.412 versus 0.547;p<0.0001) and 22.88% (0.364 versus 0.472;p=0.001), respectively, as compared with the control group. Univariate analysis showed significant correlation between rim area (mm2) and temporal ONH vessel density (r=0.623;p<0.0001) and total ONH vessel density (r=0.609;p<0.0001). Significant correlations were found between temporal and total ONH vessel density and RNFL, GCC, VF mean deviation, and visual field index.Conclusion. In glaucoma patients OCT-A might detect reduced ONH blood vessel density that is associated with structural and functional glaucomatous damage. OCT-A might become a useful tool for the evaluation of ONH microcirculation changes in glaucoma.


2013 ◽  
Vol 54 (11) ◽  
pp. 1748
Author(s):  
Geun Yeong Kim ◽  
You Kyung Lee ◽  
Jung Il Moon ◽  
Myoung Hee Park

2014 ◽  
Author(s):  
Kunakorn Palawong ◽  
Pornthep Pongchalee ◽  
Porntip Chuamchaitrakool ◽  
Sukanya Tachatraiphop ◽  
Joewono Widjaja ◽  
...  

2020 ◽  
Vol 2020 ◽  
pp. 1-7
Author(s):  
Naresh Babu Kannan ◽  
Sagnik Sen ◽  
Prithviraj Udaya ◽  
Obuli Ramachandran ◽  
Kim Ramasamy

Purpose. To study the clinicodemographic profile of dome-shaped maculopathy (DSM) eyes in the Indian population and characterization using spectral-domain optical coherence tomography (SD-OCT). Methods. This observational cross-sectional study included 25 eyes of 14 patients diagnosed with DSM. All eyes underwent SD-OCT for characterization of the dome profile and also to measure central macular thickness (CMT), subfoveal choroidal thickness (SFCT), and dome height (DH) and to detect the presence of subretinal fluid (SRF). Results. The mean age of patients was 48.36 ± 14.23 years (range, 28–65 years). Eleven patients had bilateral involvement. Mean axial length of all eyes was 24.25 ± 1.95 mm and mean spherical equivalent −4.23 ± 3.79 DS. Overall, 11/25 eyes (44%) had round domes, 9/25 eyes (36%) had horizontal domes, and 5/25 eyes (20%) had vertical domes, with a mean dome height at fovea of 500.54 ± 291.58 µm. Vertical domes had higher DH compared to horizontal or combined domes p = 0.02 . Six eyes (6/25, 24%) showed the presence of SRF; 60% of vertical domes had SRF, and 22.2% of horizontal domes had SRF. The eyes having SRF had significantly higher CMT p = 0.017 and DH p = 0.001 , especially in horizontal domes p = 0.023 . The eyes with thicker SFCT tended to have higher DH and poorer visual acuity. Conclusion. Indian DSM eyes may have relatively lesser amounts of myopia. Choroidal thickening may play a role in development of DSM and may also be related to development of subretinal fluid in such eyes.


Sign in / Sign up

Export Citation Format

Share Document