scholarly journals A hybrid fiber-optic photoluminescence measurement system and its application in InGaN/GaN light emitting diode epi-wafer morphology studies

2012 ◽  
Vol 20 (17) ◽  
pp. 19535 ◽  
Author(s):  
Sohee An ◽  
Yong Gon Seo ◽  
Woohyun Jung ◽  
Minkyu Park ◽  
Jiyoung Park ◽  
...  
2008 ◽  
Vol 47 (4) ◽  
pp. 3236-3239 ◽  
Author(s):  
Mu-Chun Wang ◽  
Zhen-Ying Hsieh ◽  
Yuan-Tai Tseng ◽  
Fan-Gang Tseng ◽  
Heng-Sheng Huang ◽  
...  

Author(s):  
Puteri Nur Syahirah Mohamed Mustafa ◽  
Aiman Shahmi Azam ◽  
Mohd Suhaimi Sulaiman ◽  
Ahmad Fairuz Omar ◽  
Mohamad Faizal Abd Rahman

<p>This paper proposed an optical pH measurement system developed to measure the changes of pH levels based on colorimetric reactions with phenol red reagent. The optical sensing was achieved through the implementation of a pair of light emitting diode (LED) and photodiode. The detection mechanism was based on different absorbance of light intensity at pH values of 2.36, 8.32, 9.08 and 12.83. The data processing method was carried out using LabVIEW software and interfaced with NI USB DAQ 6008. The measured voltage showed a good correlation in relation to the pH level with R2 equals to 0.9624. This relationship was used as a calibration curve in the final system testing. The final measurement of pH showed a good agreement between the actual and measured values with an error of less than 5%, thus indicating the reliability of the proposed system.</p>


2016 ◽  
Vol 87 (3) ◽  
pp. 035121 ◽  
Author(s):  
Christopher D. Granz ◽  
Bryan J. Schindler ◽  
Gregory W. Peterson ◽  
James E. Whitten

2002 ◽  
Vol 56 (4) ◽  
pp. 464-468 ◽  
Author(s):  
Greg E. Collins ◽  
Qin Lu ◽  
Sitra Abubeker ◽  
Elizabeth Vajs

Optimization and initial characterization of a remote probe for extremely low levels (<20 μg/L) of uranium(VI) in groundwater are described. The monitor takes advantage of a small length of Nafion cation exchange membrane tubing, which permits diffusion of the uranyl ion into an internally renewable reagent solution of Arsenazo III. The sensitive, colorimetric metal complexation of uranium(VI) by Arsenazo III is measured by recording the absorbance change in a fiber-optic SMA Z-cell that is coupled to a red-light-emitting diode. The entire system is packaged on a 2 × 11 in. breadboard and attached to a 100-ft power and data transmission cord. The final optimized pH of 1.5 was utilized for maximizing sensitivity to uranium while minimizing interferences from other metal ion impurities. The addition of 1 mM diethylenetriaminepentaacetic acid to the reagent further assisted in the elimination of metal ion interferences. Two Nafion membrane tubings with different internal diameters and wall thicknesses are evaluated. Using a 20 min diffusion time and the Nafion 20 membrane, the detection limit obtained for uranium(VI) in groundwater was 1.4 ppb. Of the twenty metal ion interferents examined, all gave essentially no response, with the exception of calcium and thorium, for which a 30 mg/L and a 100 μg/L solution, respectively, gave signals representative of 4.7 and 6.0 ppb uranium(VI).


2018 ◽  
Vol 18 (15) ◽  
pp. 6169-6174 ◽  
Author(s):  
Shih-Hua Huang ◽  
Yen-Jie Huang ◽  
Hsiang-Chen Chui