Cascade Laser Power Converter for Simultaneous 10 Gbps Data Detection and Efficient Optical-to-Electrical DC Power Generation

Author(s):  
F.-M. Kuo ◽  
S.-S. Lo ◽  
Ci-Ling Pan ◽  
J.-W. Shi
2021 ◽  
Vol 11 (13) ◽  
pp. 5793
Author(s):  
Bartosz Dominikowski

The accuracy of current measurements can be increased by appropriate amplification of the signal to within the measurement range. Accurate current measurement is important for energy monitoring and in power converter control systems. Resistance and inductive current transducers are used to measure the major current in AC/DC power converters. The output value of the current transducer depends on the load motor, and changes across the whole measurement range. Modern current measurement circuits are equipped with operational amplifiers with constant or programmable gain. These circuits are not able to measure small input currents with high resolution. This article proposes a precise loop gain system that can be implemented with various algorithms. Computer analysis of various automatic gain control (AGC) systems proved the effectiveness of the Mamdani controller, which was implemented in an MCU (microprocessor). The proposed fuzzy controller continuously determines the value of the conversion factor. The system also enables high resolution measurements of the current emitted from small electric loads (≥1 A) when the electric motor is stationary.


2021 ◽  
Vol 11 (2) ◽  
pp. 542
Author(s):  
Jaqueline Litardo ◽  
Massimo Palme ◽  
Rubén Hidalgo-León ◽  
Fernando Amoroso ◽  
Guillermo Soriano

This paper compares the potential for building energy saving of various passive and active strategies and on-site power generation through a grid-connected solar photovoltaic system (SPVS). The case study is a student welfare unit from a university campus located in the tropical climate (Aw) of Guayaquil, Ecuador. The proposed approach aims to identify the most effective energy saving strategy for building retrofit in this climate. For this purpose, we modeled the base line of the building and proposed energy saving scenarios that were evaluated independently. All building simulations were done in OpenStudio-EnergyPlus, while the on-site power generation was carried out using the Homer PRO software. Results indicated that the incorporation of daylighting controls accounted for the highest energy savings of around 20% and 14% in total building energy consumption, and cooling loads, respectively. Also, this strategy provided a reduction of about 35% and 43% in total building energy consumption, and cooling loads, respectively, when combined with triple low-e coating glazing and active measures. On the other hand, the total annual electric energy delivered by the SPVS (output power converter) was 66,590 kWh, from where 48,497 kWh was supplied to the building while the remaining electricity was injected into the grid.


2021 ◽  
Vol 118 (23) ◽  
pp. 233902
Author(s):  
An-Cheng Wang ◽  
Yu-Run Sun ◽  
Shu-Zhen Yu ◽  
Jia-Jing Yin ◽  
Wei Zhang ◽  
...  
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document