Full-field parallel interferometry coherence probe microscope for high-speed optical metrology

2015 ◽  
Vol 54 (16) ◽  
pp. 5083 ◽  
Author(s):  
A. Safrani ◽  
I. Abdulhalim
2020 ◽  
Vol 13 (3-4) ◽  
pp. 222-228
Author(s):  
И.В. Яминский ◽  
А.И. Ахметова

Разработка высокоэффективных режимов быстродействующего сканирующего зондового микроскопа, в первую очередь атомно-силовой и сканирующей капиллярной микроскопии, представляет особый интерес для успешного проведения биомедицинских исследований: изучения биологических процессов и морфологии биополимеров, определения антибио­тикорезистентности бактерий, адресной доставки биомакромолекул, скринингу лекарств, раннему обнаружению биологических агентов (вирусов и бактерий) и др. The development of highly efficient modes of a high-speed scanning probe microscope, primarily atomic force and scanning capillary microscopy, is of particular interest for successful biomedical research: studying biological processes and the morphology of biopolymers, determining antibiotic resistance of bacteria, targeted delivery of biomacromolecules, drug screening, early detection agents (viruses and bacteria), etc.


Sensors ◽  
2021 ◽  
Vol 21 (5) ◽  
pp. 1602
Author(s):  
Ángel Molina-Viedma ◽  
Elías López-Alba ◽  
Luis Felipe-Sesé ◽  
Francisco Díaz

Experimental characterization and validation of skin components in aircraft entails multiple evaluations (structural, aerodynamic, acoustic, etc.) and expensive campaigns. They require different rigs and equipment to perform the necessary tests. Two of the main dynamic characterizations include the energy absorption under impact forcing and the identification of modal parameters through the vibration response under any broadband excitation, which also includes impacts. This work exploits the response of a stiffened aircraft composite panel submitted to a multi-impact excitation, which is intended for impact and energy absorption analysis. Based on the high stiffness of composite materials, the study worked under the assumption that the global response to the multi-impact excitation is linear with small strains, neglecting the nonlinear behavior produced by local damage generation. Then, modal identification could be performed. The vibration after the impact was measured by high-speed 3D digital image correlation and employed for full-field operational modal analysis. Multiple modes were characterized in a wide spectrum, exploiting the advantages of the full-field noninvasive techniques. These results described a consistent modal behavior of the panel along with good indicators of mode separation given by the auto modal assurance criterion (Auto-MAC). Hence, it illustrates the possibility of performing these dynamic characterizations in a single test, offering additional information while reducing time and investment during the validation of these structures.


2018 ◽  
Vol 183 ◽  
pp. 02043 ◽  
Author(s):  
Bratislav Lukić ◽  
Dominique Saletti ◽  
Pascal Forquin

This paper presents the measurement results of the dynamic tensile strength of a High Performance Concrete (HPC) obtained using full-field identification method. An ultra-high speed imaging system and the virtual fields method were used to obtain this information. Furthermore the measurement results were compared with the local point-wise measurement to validate the data pressing. The obtained spall strength was found to be consistently 20% lower than the one obtained when the Novikov formula is used.


2018 ◽  
Vol 183 ◽  
pp. 02006 ◽  
Author(s):  
Amos Gilat ◽  
Jeremy D. Seidt

The Split Hopkinson Bar (SHB) technique is used for high strain rate testing of T800/F3900 composite in compression, tension and shear. Digital Image Correlation (DIC) is used for measuring the full-field deformation on the surface of the specimen by using Shimadzu HPV-X2 high-speed video camera. Compression tests have been done on specimens machined from a unidirectional laminate in the 0°and 90° directions. Tensile tests were done in the 90° direction. Shear tests were done by using a notched specimen in a compression SHB apparatus. To study the effect of strain rate, quasi-static testing was also done using DIC and specimens with the same geometry as in the SHB tests. The results show that the DIC technique provides accurate strain measurements even at strains that are smaller than 1%. No strain rate effect is observed in compression in the 0° direction and significant strain rate effects are observed in compression and tension in the 90° direction, and in shear.


2013 ◽  
Vol 273 ◽  
pp. 510-514
Author(s):  
Jing Liu ◽  
Hui Zhang ◽  
Jun Li ◽  
Da Chuan Chen ◽  
Yan Kun Tang

Digital Speckle Pattern Interferometry ( DSPI for short ) method has become one of the most practical worthy techniques for speckle measuring methods with the high-speed development of optic-electronical technique, image processing technology and electronic computer technology. There is a lot of advantages about it, such as uncomplicated operation, non-contacting, advanced automatic level, measurement on-line and extensive using. In this thesis, the displacement variation of the induced strain field for driving by piezoelectric ceramics can be measured by using this method. Thus we can come to a conclusion that digital speckle pattern interferometry is a new measuring method for extracting small-signal. It also provides a powerfully theoretical and experimental platform for study of automated, full-field, high-precision and nondestructive measurement.


2021 ◽  
Author(s):  
◽  
Adrian Peter Paul Jongenelen

<p>This thesis documents the development of a time-of-flight (ToF) camera suitable for autonomous mobile robotics applications. By measuring the round trip time of emitted light to and from objects in the scene, the system is capable of simultaneous full-field range imaging. This is achieved by projecting amplitude modulated continuous wave (AMCW) light onto the scene, and recording the reflection using an image sensor array with a high-speed shutter amplitude modulated at the same frequency (of the order of tens of MHz). The effect is to encode the phase delay of the reflected light as a change in pixel intensity, which is then interpreted as distance. A full field range imaging system has been constructed based on the PMD Technologies PMD19k image sensor, where the high-speed shuttering mechanism is builtin to the integrated circuit. This produces a system that is considerably more compact and power efficient than previous iterations that employed an image intensifier to provide sensor modulation. The new system has comparable performance to commercially available systems in terms of distance measurement precision and accuracy, but is much more flexible with regards to its operating parameters. All of the operating parameters, including the image integration time, sensor modulation phase offset and modulation frequency can be changed in realtime either manually or automatically through software. This highly configurable system serves as an excellent platform for research into novel range imaging techniques. One promising technique is the utilisation of measurements using multiple modulation frequencies in order to maximise precision over an extended operating range. Each measurement gives an independent estimate of the distance with limited range depending on the modulation frequency. These are combined to give a measurement with extended maximum range using a novel algorithm based on the New Chinese Remainder Theorem. A theoretical model for the measurement precision and accuracy of the new algorithm is presented and verified with experimental results. All distance image processing is performed on a per-pixel basis in real-time using a Field Programmable Gate Array (FPGA). An efficient hardware implementation of the phase determination algorithm for calculating distance is investigated. The limiting resource for such an implementation is random access memory (RAM), and a detailed analysis of the trade-off between this resource and measurement precision is also presented.</p>


Author(s):  
Laurin Ginner ◽  
Daniel J. Fechtig ◽  
Tilman Schmoll ◽  
Lara M. Wurster ◽  
Michael Pircher ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document