Mid-infrared multispectral confocal microscope using off-axis parabolic mirrors to study epiretinal membranes

2021 ◽  
Vol 60 (27) ◽  
pp. 8616
Author(s):  
Jiaying Zhu ◽  
Ruixing Wang ◽  
Qiao Liu ◽  
Zhifu Luo ◽  
Bei Tian ◽  
...  
Author(s):  
C J R Sheppard

The confocal microscope is now widely used in both biomedical and industrial applications for imaging, in three dimensions, objects with appreciable depth. There are now a range of different microscopes on the market, which have adopted a variety of different designs. The aim of this paper is to explore the effects on imaging performance of design parameters including the method of scanning, the type of detector, and the size and shape of the confocal aperture.It is becoming apparent that there is no such thing as an ideal confocal microscope: all systems have limitations and the best compromise depends on what the microscope is used for and how it is used. The most important compromise at present is between image quality and speed of scanning, which is particularly apparent when imaging with very weak signals. If great speed is not of importance, then the fundamental limitation for fluorescence imaging is the detection of sufficient numbers of photons before the fluorochrome bleaches.


2005 ◽  
Vol 14 ◽  
pp. 337-342 ◽  
Author(s):  
M. Dolci ◽  
G. Valentini ◽  
O. Straniero ◽  
G. Di Rico ◽  
M. Ragni ◽  
...  

2005 ◽  
Vol 43 (05) ◽  
Author(s):  
M Goetz ◽  
MF Neurath ◽  
P Delaney ◽  
S Gregor ◽  
D Strand ◽  
...  
Keyword(s):  

2018 ◽  
Author(s):  
Y. H. Kan ◽  
Changying Zhao ◽  
Zhuomin M. Zhang

2011 ◽  
Vol 28 (1) ◽  
pp. 33-48 ◽  
Author(s):  
Oto Hanuš ◽  
Václava Genčurová ◽  
Yunhai Zhang ◽  
Pavel Hering ◽  
Jaroslav Kopecký ◽  
...  

Milk acetone determination by the photometrical method after microdiffusion and via FT infra-red spectroscopyMilk acetone (AC) and betahydroxybutyrate (BHB) are important indicators of the energy metabolism of cows (ketosis occurrence) and an effective method for their determination, with reliable results, is of great importance. The goal of this work was to investigate the infrared method MIR-FT in terms of its calibration for milk AC and to develop a usable procedure. The microdiffusion photometric (485 nm; Spekol 11) method was used with salicylaldehyde as a reference (Re) and mid infrared spectroscopy FT (MIR-FT: Lactoscope FT-IR, Delta; MilkoScan FT 6000, M-Sc) as an indirect method. The acetone addition to milk had no recovery using MIR-FT (Delta). The reference AC set must have acceptable statistics for good MIR-FT calibration (M-Sc) and they were: 10.1 ± 9.74 at a geometric mean of 7.26 mg l-1, and a variation range from 1.98 to 33.66 mg l-1. The AC correlation between Re and MIR-FT (Delta) was low at 0.32 (P>0.05 but the Log AC relationship between Re and MIR-FT (M-Sc) was markedly better at 0.80 (P<0.01). The conversion of >10 mg l-1 as an AC subclinical ketosis limit could be > -0.80 (feedback 0.158 mmol l-1 = 9.25 mg l-1) and > -1.66. This could be important for ketosis monitoring (using M-Sc).


2020 ◽  
Vol 13 (4) ◽  
pp. 722-727
Author(s):  
ZHU Ye-xin ◽  
◽  
◽  
LI Ya-nan ◽  
SHI Wei-jie ◽  
...  