Orthographic double-beam holographic interferometry for limited-view optical tomography

1995 ◽  
Vol 34 (27) ◽  
pp. 6282
Author(s):  
Shaohua Chen ◽  
Suyi Huang ◽  
Dufang Shi
Measurement ◽  
1992 ◽  
Vol 10 (4) ◽  
pp. 170-181 ◽  
Author(s):  
H Philipp ◽  
T Neger ◽  
H Jäger ◽  
J Woisetschläger

2018 ◽  
Vol 10 (3) ◽  
pp. 79
Author(s):  
Marcin Jarosław Marzejon ◽  
Małgorzata Jędrzejewska-Szczerska

In this paper, we describe how commonly present in tissue substances - sodium chloride and glucose - affect the optical spectrum of an immunosuppressive drug (Cyclaid® by Apotex). Prepared samples were investigated using the spectrophotometer in the spectrum range from 250 nm to 1100 nm. The maximum wavelength shift calculated on the basis of measurement results is not bigger than the measurement wavelength step. So, it can be concluded, that the small amount of sodium chloride or glucose does not influence the measurement and it is possible to apply spectrophotometry in a point-of-care sensor of the Cyclaid® by Apotex level. Full Text: PDF ReferencesL. Taylor, C. J. E. Watson, and J. A. Bradley, "Immunosuppressive agents in solid organ transplantation: Mechanisms of action and therapeutic efficacy", Crit. Rev. Oncol. Hematol. 56, 23 (2005). CrossRef C. C. Mok, "Calcineurin inhibitors in systemic lupus erythematosus", Best Pract. Res. Clin. Rheumatol. 31, 429 (2017). CrossRef C. E. M. Griffiths et al., "Striae gravidarum in primiparae", Br. J. Dermatol. 155, 1 (2006). CrossRef F. Stucker and D. Ackermann, "Immunsuppressiva - Wirkungen, Nebenwirkungen und Interaktionen", Ther. Umschau. Rev. thérapeutique, 68 ,679 (2011). CrossRef A. Fahr, "Cyclosporin Clinical Pharmacokinetics", Clin. Pharmacokinet. 24, 472 (1993). CrossRef Cyclosporine – UpToDate, DirectLink P. Strakowska, R. Beutner, M. Gnyba et al., "Electrochemically assisted deposition of hydroxyapatite on Ti6A14V substrates covered by CVD diamond films – coating characterization and first cell biological results", Mater Sci Eng C Mater Biol Appl. 59, 624 (2016). CrossRef M. Gnyba, M. S. Wróbel, K. Karpienko et al., "Combined analysis of whole human blood parameters by Raman spectroscopy and spectral-domain low-coherence interferometry", Proc. SPIE 9537, 95371N (2015). CrossRef M. S. Wróbel, M. Gnyba, R. Urniaz et al., "Detection of propofol concentrations in blood by Raman spectroscopy", Proc. SPIE 9537, 95370Z (2015). CrossRef M. Gnyba, et al., "SAVE TO MY LIBRARY Raman spectroscopic investigation of blood and related materials", Proc. SPIE 9448, 944809 (2015). CrossRef H. S. Cho et al., "High frame-rate intravascular optical frequency-domain imaging in vivo", Biomed. Opt. Express 5, 223 (2013). CrossRef T. A. Valdez et al., "Multi-color reflectance imaging of middle ear pathology in vivo", Anal. Bioanal. Chem. 407, 3277 (2015). CrossRef M. Ali Ansari, S. Alikhani, and E. Mohajerani, "A hybrid imaging method based on diffuse optical tomography and optomechanical method to detect a tumor in the biological phantom", Opt. Commun. 342, 12 (2015). CrossRef M. S. Wróbel et al., "Multi-layered tissue head phantoms for noninvasive optical diagnostics", J. Innov. Opt. Health Sci. 08, 1541005 (2015). CrossRef D. A. Skoog, F. J. Holler, and S. R. Crouch, Principles of instrumental analysis, (Belmont, CA, Thomson Brooks/Cole 2007). CrossRef M. Hof, Basics of Optical Spectroscopy in Handbook of Spectroscopy, (Weinheim , Wiley-VCH Verlag GmbH & Co. KGaA 2005). CrossRef M. Marzejon et al,. "Optical-Spectrometry-Based Method for Immunosuppressant Medicine Level Detection in Aqueous Solutions", Sensors, 18, 2001 (2018). CrossRef UV-9000 Double Beam UV/VIS, http://en.metash.com/ProductShow_172.html CrossRef


2019 ◽  
pp. 105-110
Author(s):  
Mikhail Yongon Lee ◽  
Sergei V. Fedorov

The article describes the structure and the operation principle of the spectrophotometer developed on the basis of a compact rapid monochromator with one input port and two output ports and a radiometric unit where upwelling radiation radiance and sea surface irradiance channels are located. A new approach to measurements of spectral characteristics of upwelling radiation of sea based on combination of advantages of a double beam photometer with a photomultiplier and a directreading photometer with a highstability silicon photodiode for its absolute adjustment in energy units is implemented.


2012 ◽  
Vol 132 (3) ◽  
pp. 374-383 ◽  
Author(s):  
Yukari Tanikawa ◽  
Feng Gao ◽  
Michio Miyakawa ◽  
Toru Kiryu ◽  
Tomohiro Kizuka ◽  
...  

1998 ◽  
Vol 536 ◽  
Author(s):  
H. Porteanu ◽  
A. Glozman ◽  
E. Lifshitz ◽  
A. Eychmüller ◽  
H. Weller

AbstractCdS/HgS/CdS nanoparticles consist of a CdS core, epitaxially covered by one or two monolayers of HgS and additional cladding layers of CdS. The present paper describes our efforts to identify the influence of CdS/HgS/CdS interfaces on the localization of the photogenerated carriers deduced from the magneto-optical properties of the materials. These were investigated by the utilization of optically detected magnetic resonance (ODMR) and double-beam photoluminescence spectroscopy. A photoluminescence (PL) spectrum of the studied material, consists of a dominant exciton located at the HgS layer, and additional non-excitonic band, presumably corresponding to the recombination of trapped carriers at the interface. The latter band can be attenuated using an additional red excitation. The ODMR measurements show the existence of two kinds of electron-hole recombination. These electron-hole pairs maybe trapped either at a twin packing of a CdS/HgS interface, or at an edge dislocation of an epitaxial HgS or a CdS cladding layer.


Author(s):  
Walter Schumann ◽  
Michel Dubas

Sign in / Sign up

Export Citation Format

Share Document