Three-dimensional stress distribution measurement in a model of the human ankle joint by scattered-light polarizer photoelasticity: part 2

1987 ◽  
Vol 26 (4) ◽  
pp. 643 ◽  
Author(s):  
Toshiki Kihara ◽  
Masato Unno ◽  
Chikara Kitada ◽  
Hayao Kubo ◽  
Ryo Nagata
1988 ◽  
Vol 110 (4) ◽  
pp. 364-373 ◽  
Author(s):  
Sorin Siegler ◽  
Jie Chen ◽  
C. D. Schneck

The in-vitro, three dimensional kinematic characteristics of the human ankle and subtalar joint were investigated in this study. The main goals of this investigation were: 1) To determine the range of motion of the foot-shank complex and the associated range of motion of the ankle and subtalar joints; 2) To determine the kinematic coupling characteristics of the foot-shank complex, and 3) To identify the relationship between movements at the ankle and subtalar joints and the resulting motion produced between the foot and the shank. The tests were conducted on fifteen fresh amputated lower limbs and consisted of incrementally displacing the foot with respect to the shank while the motion of the articulating bones was measured through a three dimensional position data acquisition system. The kinematic analysis was based on the helical axis parameters describing the incremental displacements between any two of the three articulating bones and on a joint coordinate system used to describe the relative position between the bones. From the results of this investigation it was concluded that: 1) The range of motion of the foot-shank complex in any direction (dorsiflexion/plantarflexion, inversion/eversion and internal rotation/external rotation) is larger than that of either the ankle joint or the subtalar joint.; 2) Large kinematic coupling values are present at the foot-shank complex in inversion/eversion and in internal rotation/external rotation. However, only a slight amount of coupling was observed to occur in dorsiflexion/plantarflexion.; 3) Neither the ankle joint nor the subtalar joint are acting as ideal hinge joints with a fixed axis of rotation.; 4) Motion of the foot-shank complex in any direction is the result of rotations at both the ankle and the subtalar joints. However, the contribution of the ankle joint to dorsiflexion/plantarflexion of the foot-shank complex is larger than that of the subtalar joint and the contribution of the subtalar joint to inversion/eversion is larger than that of the ankle joint.; 5) The ankle and the subtalar joints have an approximately equal contribution to internal rotation/external rotation movements of the foot-shank complex.


1988 ◽  
Vol 110 (4) ◽  
pp. 374-385 ◽  
Author(s):  
Jie Chen ◽  
Sorin Siegler ◽  
Carson D. Schneck

The objective of the present study was to investigate the in-vitro, coupled, three-dimensional load-displacement and flexibility characteristics of the human ankle joint complex consisting of the talocrural and the talocalcaneal joints and to determine the effects that sectioning of the anterior talofibular ligament has on these characteristics. Similar to other anatomical joints such as the knee and the intervertebral joint, the ankle joint complex was found to exhibit highly nonlinear load-displacement characteristics with the angular displacement approaching asymptotic values as the external load was increased. Therefore, a procedure of incremental linearization was used to derive the flexibility characteristics of this structure. According to this procedure, external loads were applied to the calcaneus in small increments and its resulting three dimensional displacements were recorded. The incremental flexibility coefficients were then derived by assuming linear load-displacement relationship for each increment. From the results obtained from fifteen human ankle specimens, it was evident that the ankle joint complex exhibit highly coupled flexibility and load-displacement characteristics. It was further concluded that the ankle joint complex is the most flexible in the neighborhood of the unloaded, neutral position and that all the flexibility coefficients of the structure decrease rapidly toward the extremes of the range of motion. Rupture of the anterior talofibular ligament was found to have a significant effect on the load-displacement and flexibility characteristics of the ankle joint complex. This effect was manifested as a change in the load-displacement characteristics and a large increase in the flexibility coefficients primarily in those corresponding to rotations in the transverse and the coronal plane. The results of the present study can provide the necessary data base for the development of quantitative diagnostic technique for identifying the site and the extent of injury to the collateral ligaments of the ankle.


2021 ◽  
Vol 11 (3) ◽  
pp. 1220
Author(s):  
Azeem Ul Yaqin Syed ◽  
Dinesh Rokaya ◽  
Shirin Shahrbaf ◽  
Nicolas Martin

The effect of a restored machined hybrid dental ceramic crown–tooth complex is not well understood. This study was conducted to determine the effect of the stress state of the machined hybrid dental ceramic crown using three-dimensional finite element analysis. Human premolars were prepared to receive full coverage crowns and restored with machined hybrid dental ceramic crowns using the resin cement. Then, the teeth were digitized using micro-computed tomography and the teeth were scanned with an optical intraoral scanner using an intraoral scanner. Three-dimensional digital models were generated using an interactive image processing software for the restored tooth complex. The generated models were imported into a finite element analysis software with all degrees of freedom concentrated on the outer surface of the root of the crown–tooth complex. To simulate average occlusal load subjected on a premolar a total load of 300 N was applied, 150 N at a buccal incline of the palatal cusp, and palatal incline of the buccal cusp. The von Mises stresses were calculated for the crown–tooth complex under simulated load application was determined. Three-dimensional finite element analysis showed that the stress distribution was more in the dentine and least in the cement. For the cement layer, the stresses were more concentrated on the buccal cusp tip. In dentine, stress was more on the cusp tips and coronal 1/3 of the root surface. The conventional crown preparation is a suitable option for machined polymer crowns with less stress distribution within the crown–tooth complex and can be a good aesthetic replacement in the posterior region. Enamic crowns are a good viable option in the posterior region.


2007 ◽  
Vol 345-346 ◽  
pp. 1469-1472
Author(s):  
Gab Chul Jang ◽  
Kyong Ho Chang ◽  
Chin Hyung Lee

During manufacturing the welded joint of steel structures, residual stress is produced and weld metal is used inevitably. And residual stress and weld metal influence on the static and dynamic mechanical behavior of steel structures. Therefore, to predict the mechanical behavior of steel pile with a welded joint during static and dynamic deformation, the research on the influence of the welded joints on the static and dynamic behavior of steel pile is clarified. In this paper, the residual stress distribution in a welded joint of steel piles was investigated by using three-dimensional welding analysis. The static and dynamic mechanical behavior of steel piles with a welded joint is investigated by three-dimensional elastic-plastic finite element analysis using a proposed dynamic hysteresis model. Numerical analyses of the steel pile with a welded joint were compared to that without a welded joint with respect to load carrying capacity and residual stress distribution. The influence of the welded joint on the mechanical behavior of steel piles during static and dynamic deformation was clarified by comparing analytical results


2021 ◽  
pp. 030157422097434
Author(s):  
V Sandhya ◽  
AV Arun ◽  
Vinay P Reddy ◽  
S Mahendra ◽  
BS Chandrashekar ◽  
...  

Background and Objectives: This study was conducted to determine the effective method to torque the incisor with thermoplastic aligner using a three-dimensional (3D) finite element method. Materials and Methods: Three finite element models of maxilla and maxillary dentition were developed. In the first model, thermoplastic aligner without any auxiliaries was used. In the second and third models, thermoplastic aligner with horizontal ellipsoid composite attachment and power ridge were used, respectively. The software used for the study was ANSYS 14.5 FE. A force of 100 g was applied to torque the upper right central incisor. The resultant force transfer, stress distribution, and tooth displacement were evaluated. Results: The overall tooth displacement and stress distribution appeared high in the model with power ridge, whereas the root movement was more in the horizontal ellipsoid composite attachment model. The model without any auxillaries produced least root movement and stress distribution. Conclusion: Horizontal ellipsoid composite attachment achieved better torque of central incisor than the model with power ridge and model without any auxillaries.


Sign in / Sign up

Export Citation Format

Share Document