scholarly journals Sugar ester synthesis in binary system consisting of ionic liquids and supercritical carbon dioxide

2015 ◽  
Vol 60 (26) ◽  
pp. 2567-2572
Author(s):  
Can QUAN ◽  
ZhiXia ZHANG ◽  
ShaoKun TANG ◽  
PanPan CHANG
2016 ◽  
Vol 32 (6) ◽  
Author(s):  
Ruixia Liu ◽  
Peng Zhang ◽  
Suojiang Zhang ◽  
Ting Yan ◽  
Jiayu Xin ◽  
...  

AbstractIonic liquids (ILs) and supercritical CO


2009 ◽  
Vol 11 (4) ◽  
pp. 538 ◽  
Author(s):  
Pedro Lozano ◽  
Teresa De Diego ◽  
Corina Mira ◽  
Kimberley Montague ◽  
Michel Vaultier ◽  
...  

2021 ◽  
Author(s):  
Gholamhossein Sodeifian ◽  
Seyed Ali Sajadian ◽  
Fariba Razmimanesh ◽  
Seyed Mojtaba Hazaveie

Abstract One of the main steps in choosing the drug nanoparticle production processes by supercritical carbon dioxide (SC-CO2) is determining the solubility of the solid solute. For this purpose, the solubility of Ketoconazole (KTZ) in the SC-CO2, binary system, as well as in the SC-CO2-menthol (cosolvent), ternary system, was measured at 308–338 K and 12–30 MPa using the static analysis method. The KTZ solubility in the SC-CO2 ranged between 1.70×10− 6 and 8.02×10− 4, while drug solubility in the SC-CO2 with cosolvent varied from 2.7×10− 5 to 1.96×10− 4. This difference indicated the significant effect of menthol cosolvent on KTZ solubility in the SC-CO2. Moreover, KTZ solubilities in the two systems were correlated by several empirical and semiempirical models. Among them, Sodeifian et al., Bian et al., MST, and Bartle et al. models can more accurately correlate experimental data for the binary system than other used models. Also, the Sodeifian and Sajadian model well fitted the solubility data of the ternary system with AARD,%= 6.45, Radj= 0.995.


2014 ◽  
Vol 940 ◽  
pp. 37-40
Author(s):  
Wen Su Ji ◽  
Yu Kui Ding ◽  
Yu Qiu Xu

The solubility of TNT and RDX was measured in supercritical carbon dioxide fluid at 303.0, 308.0, 323.0, 338.0 K, and over the pressure range from 10.0 MPa to 50.0 MPa. This study examined the influences of extraction temperature, extraction pressure and support effect (SE) between molecules of TNT and RDX on their solubility in the TNT/RDX/SC-CO2 system. The results show that solubility of TNT and RDX in TNT/RDX/SC-CO2 ternary system is much higher than that in binary system. The values of SE of RDX and TNT increase first and decrease then with the pressure changing. The pressure turning point occurred over the pressure range from 25 MPa to 28 MPa for TNT and from 13 MPa to 20 MPa for RDX.


ChemSusChem ◽  
2011 ◽  
Vol 4 (8) ◽  
pp. 1035-1048 ◽  
Author(s):  
Luis Álvarez de Cienfuegos ◽  
Rafael Robles ◽  
Delia Miguel ◽  
José Justicia ◽  
Juan M. Cuerva

Sign in / Sign up

Export Citation Format

Share Document