Mitigating Particulate Matter Generation in a Commercial Cage-Free Hen House

2019 ◽  
Vol 62 (4) ◽  
pp. 877-886 ◽  
Author(s):  
Lilong Chai ◽  
Hongwei Xin ◽  
Yu Wang ◽  
Jofran Oliveira ◽  
Kailao Wang ◽  
...  

Abstract. Compared to conventional cage production systems, cage-free (CF) hen housing offers hens more space and opportunities to exercise their natural behaviors (e.g., perching, dust bathing, and foraging). However, CF housing poses a number of inherent environmental challenges, among which are high levels of particulate matter (PM) and ammonia (NH3). Spraying water on CF hen house litter (e.g., 125 mL m-2 per cm of litter depth) has been shown to mitigate generation of PM by 60% to 70% in our previous lab-scale tests. The objectives of this study were to verify the lab-scale findings of PM reduction in a commercial CF hen house in central Iowa and to evaluate the indoor air quality (e.g., PM and NH3 concentrations) and litter moisture content as affected by water spray. The commercial CF house had a nominal capacity of 50,000 laying hens and measured 154 m × 21.3 m × 3.0 m (L × W × H). A water sprinkling system was installed in half of the hen house in the length direction (treatment section), while the other half of the hen house served as the control. For each of the three trials conducted during the winter of 2017-2018, spray dosage (125 mL H2O m-2 per cm of litter depth) was set according to the initial litter depth before spraying. Results show that PM concentration was reduced by 37% to 51% in the treatment section of the CF hen house. The lower reduction efficiency in the field experiment than in the lab-scale tests was partially attributed to the fact that water spray in the commercial hen house was applied only to the open litter area, and not the litter area under the aviary system, due to limited space. Adjusting the spray dosage according to litter depth is necessary for maintaining an appreciable reduction efficiency. Litter moisture content in the treatment section was 9% to 14% higher than in the control section (15.6% vs. 14% in trial 1, 14.6% vs. 12.2% in trial 2, and 17.7% vs. 14.9% in trial 3), but NH3 concentrations in the treatment and control sections were similar during the field experiment. Keywords: Air quality, Alternative hen housing, Dust, Litter moisture content.

2020 ◽  
Author(s):  
Anu Dahal ◽  
Indira Parajuli

Abstract Indoor Air Pollution (IAP) from smoky cooking fires causes deaths over 22,800 per year being the fourth leading cause of death in Nepal. The study aims to compare the pollution level particularly Carbon Monoxide (CO) and Particulate Matter (PM 2.5 ) in different firewood species. Two households one with ICS and TCS is selected purposively to monitor the concentration of pollutants in Ward no. 3 of Gatlang, Rasuwa, Nepal. IAP Meter based on Laser Sensor principle is used to monitor real time concentration of PM 2.5 and CO. 24 hours mean concentration of PM 2.5 and 8 hours mean average concentrations of CO are found to be above the WHO and National Indoor Air Quality Guidelines i.e. For ICS using household the concentration is found to be 155.26 µg/m 3 and 9 ppm respectively and household using TCS is found to be 385.12 µg/m 3 and 12.2 ppm). Both pollutants’ concentration is found less in Abies Spectabilis than other species. Positive correlation is found in both households along with moisture content, amount of firewood used, etc. This result suggests the use of Abies Spectabilis as it emits less emission as compared to other species as it has less moisture content that reduces the concentration of air pollution. Keywords : Carbon Monoxide 1 , Particulate Matter (PM 2.5 ) 2 , Indoor Air Pollution 3


2019 ◽  
Vol 19 (17) ◽  
pp. 11199-11212 ◽  
Author(s):  
Ana Stojiljkovic ◽  
Mari Kauhaniemi ◽  
Jaakko Kukkonen ◽  
Kaarle Kupiainen ◽  
Ari Karppinen ◽  
...  

Abstract. We have numerically evaluated how effective selected potential measures would be for reducing the impact of road dust on ambient air particulate matter (PM10). The selected measures included a reduction of the use of studded tyres on light-duty vehicles and a reduction of the use of salt or sand for traction control. We have evaluated these measures for a street canyon located in central Helsinki for four years (2007–2009 and 2014). Air quality measurements were conducted in the street canyon for two years, 2009 and 2014. Two road dust emission models, NORTRIP (NOn-exhaust Road TRaffic Induced Particle emissions) and FORE (Forecasting Of Road dust Emissions), were applied in combination with the Operational Street Pollution Model (OSPM), a street canyon dispersion model, to compute the street increments of PM10 (i.e. the fraction of PM10 concentration originating from traffic emissions at the street level) within the street canyon. The predicted concentrations were compared with the air quality measurements. Both road dust emission models reproduced the seasonal variability of the PM10 concentrations fairly well but under-predicted the annual mean values. It was found that the largest reductions of concentrations could potentially be achieved by reducing the fraction of vehicles that use studded tyres. For instance, a 30 % decrease in the number of vehicles using studded tyres would result in an average decrease in the non-exhaust street increment of PM10 from 10 % to 22 %, depending on the model used and the year considered. Modelled contributions of traction sand and salt to the annual mean non-exhaust street increment of PM10 ranged from 4 % to 20 % for the traction sand and from 0.1 % to 4 % for the traction salt. The results presented here can be used to support the development of optimal strategies for reducing high springtime particulate matter concentrations originating from road dust.


Atmosphere ◽  
2021 ◽  
Vol 12 (1) ◽  
pp. 62
Author(s):  
Robert Cichowicz ◽  
Maciej Dobrzański

Spatial analysis of the distribution of particulate matter PM10, PM2.5, PM1.0, and hydrogen sulfide (H2S) gas pollution was performed in the area around a university library building. The reasons for the subject matter were reports related to the perceptible odor characteristic of hydrogen sulfide and a general poor assessment of air quality by employees and students. Due to the area of analysis, it was decided to perform measurements at two heights, 10 m and 20 m above ground level, using measuring equipment attached to a DJI Matrice 600 unmanned aerial vehicle (UAV). The aim of the measurements was air quality assessment and investigate the convergence of the theory of air flow around the building with the spatial distribution of air pollutants. Considerable differences of up to 63% were observed in the concentrations of pollutants measured around the building, especially between opposite sides, depending on the direction of the wind. To explain these differences, the theory of aerodynamics was applied to visualize the probable airflow in the direction of the wind. A strong convergence was observed between the aerodynamic model and the spatial distribution of pollutants. This was evidenced by the high concentrations of dust in the areas of strong turbulence at the edges of the building and on the leeward side. The accumulation of pollutants was also clearly noticeable in these locations. A high concentration of H2S was recorded around the library building on the side of the car park. On the other hand, the air turbulence around the building dispersed the gas pollution, causing the concentration of H2S to drop on the leeward side. It was confirmed that in some analyzed areas the permissible concentration of H2S was exceeded.


Author(s):  
James R. Hodgson ◽  
Lee Chapman ◽  
Francis D. Pope

AbstractUrban air pollution can have negative short- and long-term impacts on health, including cardiovascular, neurological, immune system and developmental damage. The irritant qualities of pollutants such as ozone (O3), nitrogen dioxide (NO2) and particulate matter (PM) can cause respiratory and cardiovascular distress, which can be heightened during physical activity and particularly so for those with respiratory conditions such as asthma. Previously, research has only examined marathon run outcomes or running under laboratory settings. This study focuses on elite 5-km athletes performing in international events at nine locations. Local meteorological and air quality data are used in conjunction with race performance metrics from the Diamond League Athletics series to determine the extent to which elite competitors are influenced during maximal sustained efforts in real-world conditions. The findings from this study suggest that local meteorological variables (temperature, wind speed and relative humidity) and air quality (ozone and particulate matter) have an impact on athletic performance. Variation between finishing times at different race locations can also be explained by the local meteorology and air quality conditions seen during races.


Author(s):  
Zhiyuan Wang ◽  
Xiaoyi Shi ◽  
Chunhua Pan ◽  
Sisi Wang

Exploring the relationship between environmental air quality (EAQ) and climatic conditions on a large scale can help better understand the main distribution characteristics and the mechanisms of EAQ in China, which is significant for the implementation of policies of joint prevention and control of regional air pollution. In this study, we used the concentrations of six conventional air pollutants, i.e., carbon monoxide (CO), sulfur dioxide (SO2), nitrogen dioxide (NO2), fine particulate matter (PM2.5), coarse particulate matter (PM10), and ozone (O3), derived from about 1300 monitoring sites in eastern China (EC) from January 2015 to December 2018. Exploiting the grading concentration limit (GB3095-2012) of various pollutants in China, we also calculated the monthly average air quality index (AQI) in EC. The results show that, generally, the EAQ has improved in all seasons in EC from 2015 to 2018. In particular, the concentrations of conventional air pollutants, such as CO, SO2, and NO2, have been decreasing year by year. However, the concentrations of particulate matter, such as PM2.5 and PM10, have changed little, and the O3 concentration increased from 2015 to 2018. Empirical mode decomposition (EOF) was used to analyze the major patterns of AQI in EC. The first mode (EOF1) was characterized by a uniform structure in AQI over EC. These phenomena are due to the precipitation variability associated with the East Asian summer monsoon (EASM), referred to as the “summer–winter” pattern. The second EOF mode (EOF2) showed that the AQI over EC is a north–south dipole pattern, which is bound by the Qinling Mountains and Huaihe River (about 35° N). The EOF2 is mainly caused by seasonal variations of the mixed concentration of PM2.5 and O3. Associated with EOF2, the Mongolia–Siberian High influences the AQI variation over northern EC by dominating the low-level winds (10 m and 850 hPa) in autumn and winter, and precipitation affects the AQI variation over southern EC in spring and summer.


Author(s):  
Laurentiu Predescu ◽  
Daniel Dunea

Optical monitors have proven their versatility into the studies of air quality in the workplace and indoor environments. The current study aimed to perform a screening of the indoor environment regarding the presence of various fractions of particulate matter (PM) and the specific thermal microclimate in a classroom occupied with students in March 2019 (before COVID-19 pandemic) and in March 2021 (during pandemic) at Valahia University Campus, Targoviste, Romania. The objectives were to assess the potential exposure of students and academic personnel to PM and to observe the performances of various sensors and monitors (particle counter, PM monitors, and indoor microclimate sensors). PM1 ranged between 29 and 41 μg m−3 and PM10 ranged between 30 and 42 μg m−3. It was observed that the particles belonged mostly to fine and submicrometric fractions in acceptable thermal environments according to the PPD and PMV indices. The particle counter recorded preponderantly 0.3, 0.5, and 1.0 micron categories. The average acute dose rate was estimated as 6.58 × 10−4 mg/kg-day (CV = 14.3%) for the 20–40 years range. Wearing masks may influence the indoor microclimate and PM levels but additional experiments should be performed at a finer scale.


Atmosphere ◽  
2021 ◽  
Vol 12 (4) ◽  
pp. 460
Author(s):  
Jiun-Horng Tsai ◽  
Ming-Ye Lee ◽  
Hung-Lung Chiang

The Community Multiscale Air Quality (CMAQ) measurement was employed for evaluating the effectiveness of fine particulate matter control strategies in Taiwan. There are three scenarios as follows: (I) the 2014 baseline year emission, (II) 2020 emissions reduced via the Clean Air Act (CAA), and (III) other emissions reduced stringently via the Clean Air Act. Based on the Taiwan Emission Data System (TEDs) 8.1, established in 2014, the emission of particulate matter 2.5 (PM2.5) was 73.5 thousand tons y−1, that of SOx was 121.3 thousand tons y−1, and that of NOx was 404.4 thousand tons y−1 in Taiwan. The CMAQ model simulation indicated that the PM2.5 concentration was 21.9 μg m−3. This could be underestimated by 24% in comparison with data from the ambient air quality monitoring stations of the Taiwan Environmental Protection Administration (TEPA). The results of the simulation of the PM2.5 concentration showed high PM2.5 concentrations in central and southwestern Taiwan, especially in Taichung and Kaohsiung. Compared to scenario I, the average annual concentrations of PM2.5 for scenario II and scenario III showed reductions of 20.1% and 28.8%, respectively. From the results derived from the simulation, it can be seen that control of NOx emissions may improve daily airborne PM2.5 concentrations in Taiwan significantly and control of directly emitted PM2.5 emissions may improve airborne PM2.5 concentrations each month. Nevertheless, the results reveal that the preliminary control plan could not achievethe air quality standard. Therefore, the efficacy and effectiveness of the control measures must be considered to better reduce emissions in the future.


Sign in / Sign up

Export Citation Format

Share Document