PATHOGEN FATE IN WASTEWATER SOIL ABSORPTION SYSTEMS AS AFFECTED BY EFFLUENT QUALITY AND SOIL CLOGGING GENESIS

2013 ◽  
Author(s):  
Sheila Van Cuyk ◽  
Robert L. Siegrist
1989 ◽  
Vol 24 (3) ◽  
pp. 345-354
Author(s):  
David L. Putnam

Abstract Public concern over toxic contaminants in drinking water and the environment in general has put increasing pressure on governments to develop and enforce stringent environmental regulations. An overview of developments in Canadian federal and provincial legislation related to the regulation of petroleum refinery effluent quality is provided. Current knowledge of Canadian petroleum refinery effluent quality and level of treatment is summarized.


1991 ◽  
Vol 23 (7-9) ◽  
pp. 1457-1466 ◽  
Author(s):  
Kazuhiro Tanaka ◽  
Minoru Tada ◽  
Mitsuo Ito ◽  
Noritugu Shimizu

Biofilm processes are, in general, suitable for small-scale wastewater treatment plants. However, final effluent qualities of biofilm processes are not as good as those of activated sludge processes due to fine particles remaining in the effluents. To improve the effluent qualities of the Rotating Biological Contactors (RBC) process, the behavior of fine particles through the process and the removal of fine particles with solids-liquid separation methods, rapid filtration and coagulation-filtration, were investigated using the particle fraction method. The results are as follows:–An increase of the hydraulic retention time (HRT) in the RBC reactor reduced the amount of fine particles and increased the amount of coarse suspended solids of 44 µm or more in diameter, which are easily removed by clarification. Thus, the final effluent qualities were improved by the increase of HRT.–Suspended solids in effluent from the RBC process at the standard loading are so fine that improvement of the quality is not expected by only lowering the overflow rate of a final clarifier. In contrast, rapid filtration or a coagulation-filtration process is effective. The supended solid concentration and transparency of the effluent from the final clarifier was improved by a factor of two to four, and then BOD of the final effluent was removed by 40-85%.


1987 ◽  
Vol 19 (10) ◽  
pp. 51-59 ◽  
Author(s):  
W. V. Alexander ◽  
A. Wood

South Africa is a relatively water-short country which has many rural communities with water-borne sewage infrastructures requiring low technology treatment facilities. In order to protect the water resources of the country the authorities have set high standards for effluent quality (COD < 75 mg/l, NH3 < 10 mg/l, E. coli < 1000 and in some areas P < 1 mg/l). Traditionally, oxidation ponds have been used in these applications but have not been able to consistently meet the required standards and recently interest has been shown in artificial wetlands as a low technology means of solving the problem. As a result several experimental projects are at present being initiated in South Africa, both as primary and secondary treatment for domestic sewage and also as a tertiary treatment to remove nitrogen, phosphorus and E. coli from conventional sewage plant effluents. The designs of these experimental projects are described in the paper and it is hoped that data will be available for presentation at the seminar.


1990 ◽  
Vol 22 (3-4) ◽  
pp. 65-72 ◽  
Author(s):  
H.-H. Schierup ◽  
H. Brix

Since 1983 approximately 150 full-scale emergent hydrophyte based wastewater treatment plants (reed beds) have been constructed in Denmark to serve small wastewater producers. The development of purification performance for 21 plants representing different soil types, vegetation, and hydraulic loading rates has been recorded. Cleaning efficiencies were typically in the range of 60-80% reduction for BOD, 25-50% reduction for total nitrogen, and 20-40% reduction for total phosphorus. The mean effluent BOD, total nitrogen and total phosphorus concentrations of the reed beds were 19 ± 10, 22 ± 9 and 6.7 ± 3.2 mg/l (mean ± SD), respectively. Thus, the general Danish effluent standards of 8 mg/l for N and 1.5 mg/l for P for sewage plants greater than 5,000 PE cannot be met by the present realised design of EHTS. The main problem observed in most systems is a poor development of horizontal hydraulic conductivity in the soil which results in surface run-off. Since the political demands for effluent quality will be more strict in the future, it is important to improve the performance of small decentral sewage treatment plants. On the basis of experiences from different types of macrophyte based and conventional low-technology wastewater treatment systems, a multi-stage system is suggested, consisting of sedimentation and sand filtration facilities followed by basins planted with emergent and submergent species of macrophytes and algal ponds.


1987 ◽  
Vol 19 (12) ◽  
pp. 265-271
Author(s):  
P. R. Thomas ◽  
H. O. Phelps

The investigation was based on two facultative stabilization ponds initially designed to operate in parallel, and now receive wastewater in excess of their capacities from a fast expanding housing estate in the Caribbean Island of Trinidad. Because of the deterioration of the effluent quality relative to acceptable standards, an attempt was made to upgrade the ponds using water hyacinths at the early stages. However, from the results, it was clear that the introduction of water hyacinths in the test pond did not lead to any substantial improvement in the effluent because of the high loading on the pond. Therefore the ponds were modified to operate in series with surface aerators installed in the first pond. Initially, the effluent quality was monitored in terms of total suspended solids, volatile suspended solids, biochemical oxygen demand, faecal coliform bacteria, pH and dissolved oxygen with aeration in the first pond and no aquatic plants in the second pond. Although there was a significant improvement in the effluent quality, the values remained above the standards. As a result, water hyacinths were introduced in the second pond and the effluent quality monitored together with aeration in the first pond. The effluent quality improved with total suspended solids and biochemical oxygen demand values both as low as 10 mg/l in certain months, but additional treatment was needed to reduce faecal conforms.


1986 ◽  
Vol 18 (2) ◽  
pp. 179-184
Author(s):  
R. J. Kent

The background to and the rationale for the Guidelines for Municipal Type Wastewater Discharges in the Northwest Territories is discussed. Particu1ar attention is given to the development of Table 2.1, Effluent Quality of Municipal Wastewater Discharges, which was based upon expected lagoon performance. Also included is a discussion of the flow ratio and dilution ratio concepts. The viability of these concepts was assessed against the available data. It appears that the guidelines misjudged both the number of coliform bacteria in northern raw sewage and the removal efficiency for these organisms in lagoons. It appears unlikely that lagoons can consistently meet the guideline requirements. More information and research is necessary before a complete assessment can be performed.


1991 ◽  
Vol 24 (5) ◽  
pp. 189-196 ◽  
Author(s):  
S. B. Guo ◽  
R. Z. Chen ◽  
G. Li ◽  
H. Y. Shoichi

In 1987 Guangzhou Liede Nightsoil Treatment Plant started commissioning. The purpose of the plant is to dispose of 400 tons of nightsoi1 from city public toilets per day. In the first year of the commissioning a biological process was basically used according to the original design made by a Danish company. Practically it has been proved that the design is effective. The process can reduce BOD from 3800 mg/l to about 133 mg/l, or by approximately 96.5 percent. The performance of the sludge digester system is satisfactory. Because the primary investigation on characteristics of the nightsoil was insufficient there were some problems raised during the commissioning. So in the first year the effluent failed to achieve the desired quality. After the analysis of the plant performance some necessary reforms have been carried out. Now the effluent quality can stably meet the national discharge limits and the treatment cost decreases.


1989 ◽  
Vol 21 (10-11) ◽  
pp. 1389-1402 ◽  
Author(s):  
R. Zaloum

Deviations from design expectations appear to stem from views which assume that a unique response should result from a given set of operating conditions. The results of this study showed that two systems operating at equal organic loads or F/M ratios and at the same SRT do not necessarily give equal responses. This deviation was linked to the manner in which the HRT and influent COD are manipulated to obtain a constant or uniform load, and to subtle interactions between influent COD, HRT and SRT on the biomass and effluent responses. Increases of up to 200% in influent COD from one steady level to the next did not significantly influence the effluent VSS concentration while an effect on filtered COD was observed for increases as low as 20%. Effluent TKN and filtered COD correlated strongly with the operating MLVSS while phosphorus residual depended on the operating SRT and the organic load removed. These results point to the inadequacy of traditional models to predict effluent quality and point to the need to consider these effects when developing simulation techniques or computer assisted expert systems for the control of waste treatment plants.


1996 ◽  
Vol 33 (1) ◽  
pp. 81-87
Author(s):  
L. Van Vooren ◽  
P. Willems ◽  
J. P. Ottoy ◽  
G. C. Vansteenkiste ◽  
W. Verstraete

The use of an automatic on-line titration unit for monitoring the effluent quality of wastewater plants is presented. Buffer capacity curves of different effluent types were studied and validation results are presented for both domestic and industrial full-scale wastewater treatment plants. Ammonium and ortho-phosphate monitoring of the effluent were established by using a simple titration device, connected to a data-interpretation unit. The use of this sensor as the activator of an effluent quality proportional sampler is discussed.


Sign in / Sign up

Export Citation Format

Share Document