A COMPARISON OF FOUR FIELD METHODS FOR MEASURING SATURATED HYDRAULIC CONDUCTIVITY

1990 ◽  
Vol 33 (6) ◽  
pp. 1925-1931 ◽  
Author(s):  
J.D. Dorsey ◽  
A. D.Ward ◽  
N.R.Fausey ◽  
E. S.Bair
1993 ◽  
Vol 36 (1) ◽  
pp. 51-55 ◽  
Author(s):  
R. K. Gupta ◽  
R. P. Rudra ◽  
W. T. Dickinson ◽  
N. K. Patni ◽  
G. J. Wall

1985 ◽  
Vol 65 (3) ◽  
pp. 563-573 ◽  
Author(s):  
D. M. LEE ◽  
D. E. ELRICK ◽  
W. D. REYNOLDS ◽  
B. E. CLOTHIER

The saturated hydraulic conductivity, Ks, was measured on a loamy sand, a fine sandy loam, a silt loam and a clay at four 100-m2-area sites in southern Ontario. Twenty measurements of Ks were obtained by each of three different measurement techniques at each of the four sites. The techniques included: (1) the air-entry permeameter method; (2) the constant head well permeameter method using the Guelph Permeameter; and (3) the falling-head permeameter method applied to small soil cores. The Ks data were found to be better described by the log-normal frequency distribution than by the normal frequency distribution. Statistical comparison of the mean Ks values [Formula: see text] indicated significant differences between some or all of the methods within each site. This site-method interaction was interpreted in terms of the influence of macropores and air entrapment on each of the measurement techniques. The measured Ks values ranged over an order of magnitude on the sand, one to two orders of magnitude on the loams, and three orders of magnitude on the clay. The [Formula: see text] estimates averaged over the three methods were: 3 × 10−5 m∙s−1 for the sand; 2 × 10−6 m∙s−1 for the loams and 1 × 10−7 m∙s−1 for the clay. Although all techniques were able to discriminate between the three soil types, the best choice of method for any particular situation appears dependent on the required type and accuracy of the Ks measurement, soil type, and the various practical constraints on the investigation. Key words: Air-entry permeameter, Guelph Permeameter, falling-head permeameter, spatial variability, macropores, entrapped air


1990 ◽  
Vol 21 (2) ◽  
pp. 119-132 ◽  
Author(s):  
Johnny Fredericia

The background for the present knowledge about hydraulic conductivity of clayey till in Denmark is summarized. The data show a difference of 1-2 orders of magnitude in the vertical hydraulic conductivity between values from laboratory measurements and field measurements. This difference is discussed and based on new data, field observations and comparison with North American studies, it is concluded to be primarily due to fractures in the till.


2019 ◽  
Vol 34 (2) ◽  
pp. 237-243
Author(s):  
Jari Hyväluoma ◽  
Mari Räty ◽  
Janne Kaseva ◽  
Riikka Keskinen

2021 ◽  
Vol 13 (13) ◽  
pp. 7301
Author(s):  
Marcin K. Widomski ◽  
Anna Musz-Pomorska ◽  
Wojciech Franus

This paper presents research considering hydraulic as well as swelling and shrinkage characteristics of potential recycled fine particle materials for compacted clay liner for sustainable landfills. Five locally available clay soils mixed with 10% (by mass) of NaP1 recycled zeolite were tested. The performed analysis was based on determined plasticity, cation exchange capacity, coefficient of saturated hydraulic conductivity after compaction, several shrinkage and swelling characteristics as well as, finally, saturated hydraulic conductivity after three cycles of drying and rewetting of tested specimens and the reference samples. The obtained results showed that addition of zeolite to clay soils allowed reduction in their saturated hydraulic conductivity to meet the required threshold (≤1 × 10−9 m/s) of sealing capabilities for compacted clay liner. On the other hand, an increase in plasticity, swelling, and in several cases in shrinkage, of the clay–zeolite mixture was observed. Finally, none of the tested mixtures was able to sustain its sealing capabilities after three cycles of drying and rewetting. Thus, the studied clayey soils mixed with sustainable recycled zeolite were assessed as promising materials for compacted liner construction. However, the liner should be operated carefully to avoid extensive dissication and cracking.


Sign in / Sign up

Export Citation Format

Share Document