A novel low-profile flow sensor for monitoring of hemodynamics in cerebral aneurysm

2015 ◽  
Vol 2 (2) ◽  
pp. 71-84 ◽  
Author(s):  
Yanfei Chen ◽  
Brian T. Jankowitz ◽  
Sung Kwon Cho ◽  
Woon-Hong Yeo ◽  
Youngjae Chun
2015 ◽  
Author(s):  
Yanfei Chen ◽  
Brian T. Jankowitz ◽  
Sung Kwon Cho ◽  
Youngjae Chun

2020 ◽  
pp. 159101992096188
Author(s):  
Mario Martínez-Galdámez ◽  
Miguel Schüller-Arteaga ◽  
Jorge Galván-Fernández ◽  
Vladimir Kalousek ◽  
Ezequiel Petra ◽  
...  

Flow diverter devices have become a routine first-line option for treatment of an increasing population of intracranial aneurysms at many neurovascular centers.  Despite the promising results of flow diverter stents on anterior circulation, incomplete occlusion on the presence of fetal posterior circulation has been described on several reports.  Here we describe a novel technical alternative to conventional flow diversion approach for this specific subgroup of aneurysms using the low-profile flow diverter, Silk Vista Baby. The device was selectively placed into the fetal type posterior cerebral artery in half-T configuration for the treatment of a posterior communicating aneurysm using a transcirculation approach through the anterior communicating artery. This represents a useful and effective technique and should be considered when encountering the above-described situation.


2019 ◽  
Vol 11 (7) ◽  
pp. 723-727 ◽  
Author(s):  
Mario Martínez-Galdámez ◽  
Alessandra Biondi ◽  
Vladimir Kalousek ◽  
Vitor M Pereira ◽  
Giuseppe Ianucci ◽  
...  

PurposeThe aim of our study was to assess the technical success and the safety of this new low-profile flow diverter Silk Vista Baby (SVB) by evaluating the intraprocedural and periprocedural complication rate.Material/methodsClinical, procedural, and angiographic data were analyzed.Results: 41 consecutive patients (28 women; age average 50.5 years) with 43 aneurysms were treated with SVB. Aneurysm sizes were classified by their maximum diameter, with an average size of 9.5 mm (range 2–30 mm). Thirty-four cases were unruptured. five aneurysms previously ruptured, had recurrence after the initial coiling. There were two ruptured cases. Aneurysms' locations were: M1 segment (five cases), M2 segment (three cases), M3 segment (one case), middle cerebral artery (MCA) bifurcation (six cases), carotid-T (two cases), anterior communicating artery/A1/A2 (11 cases), pericallosal artery (four cases), supraclinoid ICA (two cases), PCom (one case), V4 segment (three cases), PCA (three cases), SCA (one case), and PICA (one case). We had five intraprocedural complications which resolved without clinical consequences and three events postprocedural events. Initial occlusion rates were: eight aneurysms (18.6%) were completely occluded, five aneurysms (11.6%) showed near-complete occlusion, four cases (9.3%) showed incomplete filling, and 26 cases (60.4%) showed persisting filling. The mRS score at discharge from the hospital did not change from the admission mRS score.ConclusionOur study demonstrated that the use of the new low-profile flow diverter, SVB device, for the treatment of intracranial aneurysms is feasible and technically safe.


2021 ◽  
Vol 12 ◽  
Author(s):  
Marie-Sophie Schüngel ◽  
Ulf Quäschling ◽  
Erik Weber ◽  
Manuel Florian Struck ◽  
Jens Maybaum ◽  
...  

Background and Purpose: Low-profile flow diverter stents (FDS) quite recently amended peripheral segments as targets for hemodynamic aneurysm treatment; however, reports on outcomes, especially later than 3 months, are scarce. This study therefore reports our experience with the novel silk vista baby (SVB) FDS and respective outcomes after 8 and 11 months with special respect to specific adverse events.Materials and Methods: Forty-four patients (mean age, 53 years) harboring 47 aneurysms treated with the SVB between June 2018 and December 2019 were included in our study. Clinical, procedural, and angiographic data were collected. Follow-ups were performed on average after 3, 8, and 11 months, respectively. Treatment effect was assessed using the O'Kelly Marotta (OKM) grading system.Results: Overall, angiographic follow-ups were available for 41 patients/45 aneurysms. Occlusion or significant reduction in aneurysmal perfusion (OKM: D1, B1–B3 and A2–A3) was observed in 98% of all aneurysms after 8 months. Only 2% of the treated aneurysms remained morphologically unaltered and without an apparent change in perfusion (OKM A1). Adverse events in the early post-interventional course occurred in seven patients; out of them, mRS-relevant morbidity at 90 days related to FDS treatment was observable in two patients. One death occurred in the context of severe SAH related to an acutely ruptured dissecting aneurysm of the vertebral artery.Conclusion: The SVB achieves sufficient occlusion rates of intracranial aneurysms originating from peripheral segments, which are comparable to prior established conventional FDS with acceptably low complication rates. However, alteration of a hemodynamic equilibrium in distal localizations requires special attention to prevent ischemic events.


2007 ◽  
Vol 3 (10) ◽  
pp. 1-12
Author(s):  
DOUG BRUNK
Keyword(s):  

Author(s):  
J Wiskirchen ◽  
K Brechtel ◽  
A Fischmann ◽  
G Tepe ◽  
S Miller ◽  
...  
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document