scholarly journals Atmospheric Aerosols: Air Quality and Climate Change Perspectives

2015 ◽  
Vol 10 (3) ◽  
pp. 738-746 ◽  
Author(s):  
Shabana Manzoor ◽  
Umesh Kulshrestha

Recently, air quality has become a matter of concern of everyone. According to the reports, atmospheric aerosols play very crucial role in air quality. PM10 and PM2.5 aerosols are integral parts of total suspended particulate matter which affect our health. Often air quality has been reported very poor due to violation of National Ambient Air Quality Standard (NAAQS) limits. PM10 and PM2.5 limits are crossed for both residential as well as sensitive sites. This is one of the major reasons of increasing cases of respiratory diseases in urban areas. However, aerosol loadings alone are not the factor for deciding or predicting toxic and harmful effects of aerosols. Chemical composition and size ranges do matter. Aerosol loadings can be due to three major source categories viz. marine, crustal and anthropogenic. Since, marine and crustal content of aerosols are generally non-toxic and hence, degree of toxicity of air needs to be decided on the basis of anthropogenic fraction having metals, PAHs and other harmful content. Apart from air quality and health, atmospheric aerosols play vital role in other atmospheric processes such as cloud formation, radiative transfer and monsoon etc. Though there are several studies reported on different aspects of atmospheric aerosols, but most of the findings are sort of data reporting based on short term observations. Hence, there is need to investigate the atmospheric aerosols in order to demonstrate local and regional phenomenon on the basis of long term datasets.

2009 ◽  
Vol 18 (3) ◽  
pp. 336 ◽  
Author(s):  
Yongqiang Liu ◽  
Scott Goodrick ◽  
Gary Achtemeier ◽  
William A. Jackson ◽  
John J. Qu ◽  
...  

This study investigates smoke incursion into urban areas by examining a prescribed burn in central Georgia, USA, on 28 February 2007. Simulations were conducted with a regional modeling framework to understand transport, dispersion, and structure of smoke plumes, the air quality effects, sensitivity to emissions, and the roles of burn management strategy in mitigating the effects. The results indicate that smoke plumes first went west, but turned north-west at noon owing to a shift in wind direction. The smoke then invaded metropolitan Atlanta during the evening rush hour. The plumes caused severe air quality problems in Atlanta. Some hourly ground PM2.5 (particulate matter not greater than 2.5 μm in diameter) concentrations at three metropolitan Atlanta locations were three to four times as high as the daily (24-h) US National Ambient Air Quality Standard. The simulated shift in the smoke transport direction and the resultant effects on air quality are supported by the satellite and ambient air measurements. Two sensitivity simulations indicate a nearly linear relation between the emission intensities and PM2.5 concentrations. Two other simulations indicate that the impacts on air quality for the residents of Atlanta during the evening commute could have been reduced if the starting time of the burn had been altered.


2013 ◽  
Vol 807-809 ◽  
pp. 20-23 ◽  
Author(s):  
Tao Sheng ◽  
Jian Wu Shi ◽  
Sen Lin Tian ◽  
Li Mei Bi ◽  
Hao Deng ◽  
...  

According to the information of air quality which published by the urban air quality real-time publishing platform, the concentration characteristics of PM10 and PM2.5 were studied in Kunming (KM), Changsha (CS), Hangzhou (HZ), Shanghai (SH), Harbin (HEB), Beijing (BJ), Wuhan (WH) and Guangzhou (GZ). The results show that the concentrations of PM10 and PM2.5 exceeded the Ambient Air Quality Standard (GB3095-2012) in varying degrees in March, 2013. The concentrations of PM10 in Wuhan is the highest, reached 164μg/m3, exceeded the standard by 9.3%; the concentrations of PM2.5 is much higher in Wuhan, Changsha and Beijing, the average concentrations were 96μg/m3, 103μg/m3 and 110μg/m3, exceeded the standard by 28.0%, 37.3% and 46.7% respectively. The correlation of PM10 with PM2.5 in most of these cities was good in March. The correlation analysis of pollutant with meteorological factor in Hangzhou, Shanghai, Beijing and Guangzhou was also studied, the results show that the concentrations of PM10 and PM2.5 are weakly positive correlation with temperature in the four cities, negative correlation with relative humidity without Beijing, and negative correlation with wind speed.


Jurnal Dampak ◽  
2017 ◽  
Vol 13 (2) ◽  
pp. 1
Author(s):  
Vera Surtia Bachtiar ◽  
Puspa Safitri Sanggar Rani

The purpose of this research are to analysis air quality and dust impact to people that came from factory activities at residential area around factory location of PT. Semen Padang. Measuring of air quality conducted in 3 residential area that are Komplek RW 1, RT 3 Batu Gadang district, Perumnas Indarung RW. VII, and housing of UNAND Blok D Gadut, using Personal Dust Sampler. The result is respirable dust concentration at housing complex RW. 1 RT. 3 Batu Gadang district that is 0,33 mg/m, the Perumnas Indarung RW.VII that is 0,55 mg/m along with housing of UNAND Blok D Gadut that is 0,44 mg/m. Concentration of dust respirable at all are still below ambient air quality standard that exist on PP RI No. 41 Tahun 1999, 3 mg/m. Based on quesioner and puskesmas data proximate with use univariat analysis, negative impact who feels people are impact of health is eyes irritation disease and impact of environment especially community-owned material. Keywords: air quality, negative impact, residential area, respirable dust, PT. Semen Padang ABSTRAKPenelitian ini bermaksud untuk menganalisis kualitas udara dan dampak negatif yang dirasakan masyarakat dari debu yang berasal dari aktivitas pabrik di kawasan perumahan sekitar lokasi pabrik PT. Semen Padang. Pengukuran kualitas udara dilakukan di 3 kawasan perumahan yaitu komplek perumahan RW. 1 RT. 3 Kelurahan Batu Gadang, Perumnas Indarung RW. VII, dan Perumahan UNAND Blok D Gadut dengan menggunakan alat Personal Dust Sampler. Diperoleh hasil konsentrasi debu respirable pada komplek perumahan RT.3 RW.1 Kelurahan Batu Gadang sebesar 0,33 mg/m, pada Perumnas Indarung RW.VII sebesar 0,55 mg/m serta pada Perumahan UNAND Blok D Gadut sebesar 0,44 mg/m. Konsentrasi debu respirable pada ketiga lokasi masih berada di bawah ambang batas baku mutu udara di lingkungan, 3 mg/m. Berdasarkan kuesioner dan data puskesmas terdekat dengan menggunakan analisis univariat, dampak negatif yang dirasakan masyarakat adalah dampak terhadap kesehatan berupa penyakit iritasi mata dan dampak terhadap lingkungan khususnya pada kondisi material yang dimiliki masyarakat.Kata kunci: kualitas udara, dampak negatif, kawasan perumahan, debu respirable, PT. Semen Padang