scholarly journals Parameters for Contrast-Enhanced Ultrasound (CEUS) of Enlarged Superficial Lymph Nodes for the Evaluation of Therapeutic Response in Lymphoma: A Preliminary Study

2017 ◽  
Vol 23 ◽  
pp. 5430-5438 ◽  
Author(s):  
Lei Xin ◽  
Zhimei Yan ◽  
Xiaojuan Zhang ◽  
Yichen Zang ◽  
Zhaoyan Ding ◽  
...  
2019 ◽  
Vol 30 (3) ◽  
pp. 1426-1435
Author(s):  
Ziyue Hu ◽  
Xueqing Cheng ◽  
Juan Li ◽  
Jingzhen Jiang ◽  
Zirui Jiang ◽  
...  

2019 ◽  
Vol 8 (4) ◽  
pp. 37-44 ◽  
Author(s):  
E. V. Kovaleva ◽  
T. Yu. Danzanova ◽  
G. T. Sinyukova ◽  
P. I. Lepedatu ◽  
E. A. Gudilina ◽  
...  

In this article, based on two clinical examples, the possibilities of multiparametric ultrasound in the differential diagnosis of metastatic and lymphoproliferative changes in lymph nodes in primary-multiple malignant tumors, including breast cancer and lym - phoma, are evaluated. Multiparameteric ultrasound includes B-mode, color and energy Doppler imaging, strain elastography, shear wave elastography and contrast-enhanced ultrasound (CEUS). Standardization and reproducibility of these ultrasound techniques will allow to objectify the study, obtaining specific indicators of shear wave velocity in the zones of interest and specific signs of contrast enhancement, which can be used as impor tant differential diagnostic tool in oncology.


2020 ◽  
Vol 9 (5) ◽  
pp. 1504 ◽  
Author(s):  
Simone Schiaffino ◽  
Francesca Serpi ◽  
Duccio Rossi ◽  
Valerio Ferrara ◽  
Ciriaco Buonomenna ◽  
...  

The reproducibility of contrast-enhanced ultrasound (CEUS) and standard B-mode ultrasound in the assessment of radiofrequency-ablated volume of benign thyroid nodules was compared. A preliminary study was conducted on consecutive patients who underwent radiofrequency ablation (RFA) of benign thyroid nodules between 2014 and 2016, with available CEUS and B-mode post-ablation checks. CEUS and B-mode images were retrospectively evaluated by two radiologists to assess inter- and intra-observer agreement in the assessment of ablated volume (Bland–Altman test). For CEUS, the mean inter-observer difference (95% limits of agreement) was 0.219 mL (-0.372–0.809 mL); for B-mode, the mean difference was 0.880 mL (-1.655–3.414 mL). Reproducibility was significantly higher for CEUS (85%) than for B-mode (27%). Mean intra-observer differences (95% limits of agreement) were 0.013 mL (0.803–4.097 mL) for Reader 1 and 0.031 mL (0.763–3.931 mL) for Reader 2 using CEUS, while they were 0.567 mL (-2.180–4.317 mL, Reader 1) and 0.759 mL (-2.584–4.290 mL, Reader 2) for B-mode. Intra-observer reproducibility was significantly higher for CEUS (96% and 95%, for the two readers) than for B-mode (21% and 23%). In conclusion, CEUS had higher reproducibility and inter- and intra-observer agreement compared to conventional B-mode in the assessment of radiofrequency-ablated volume of benign thyroid nodules.


2017 ◽  
Vol 46 (3) ◽  
pp. 20160345 ◽  
Author(s):  
Shalva R Gvetadze ◽  
Ping Xiong ◽  
Mingming Lv ◽  
Jun Li ◽  
Jingzhou Hu ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document